Publicação

Turbidimetric flow-injection determination of total nitrogen and potassium in vegetables

Ver documento

Detalhes bibliográficos
Resumo:A turbidimetric flow-injection system was developed for the determination of total nitrogen and potassium in vegetable samples using a single spectrophotometer as detector. As a precipitating agent, 3.0% (w/v) sodium tetraphenylboron solution prepared in 2.0% (w/v) poly(vinyl alcohol) was used. A gas diffusion process was included in the manifold to separate ammonium ions from the rest of the sample and to allow paired analysis. Total nitrogen and potassium determinations were carried out on the solutions remaining in the acceptor and donor streams, respectively. Results obtained were precise (relative standard deviations <2.1 and 1.6% for total N (<25 mg g−1) and K (<55 mg g−1) determinations, respectively) and in agreement with those of reference methods. Analysis can be carried out at a rate of up to 35 samples per hour (corresponding to 70 determinations per hour) within concentration range 87–430 mg N–NH+4 l−1 and 78–390 mg K+ l−1 for the total nitrogen and potassium determinations, respectively.
Autores principais:Lima, José L.F.C.
Outros Autores:Rangel, António O.S.S.; Souto, M.Renata S.; Zagatto, Elias A. G.
Assunto:Flow-injection Turbidimetric sequential determination Nitrogen Potassium Vegetables
Ano:1997
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso restrito
Instituição associada:Universidade Católica Portuguesa
Idioma:inglês
Origem:Veritati - Repositório Institucional da Universidade Católica Portuguesa
Descrição
Resumo:A turbidimetric flow-injection system was developed for the determination of total nitrogen and potassium in vegetable samples using a single spectrophotometer as detector. As a precipitating agent, 3.0% (w/v) sodium tetraphenylboron solution prepared in 2.0% (w/v) poly(vinyl alcohol) was used. A gas diffusion process was included in the manifold to separate ammonium ions from the rest of the sample and to allow paired analysis. Total nitrogen and potassium determinations were carried out on the solutions remaining in the acceptor and donor streams, respectively. Results obtained were precise (relative standard deviations <2.1 and 1.6% for total N (<25 mg g−1) and K (<55 mg g−1) determinations, respectively) and in agreement with those of reference methods. Analysis can be carried out at a rate of up to 35 samples per hour (corresponding to 70 determinations per hour) within concentration range 87–430 mg N–NH+4 l−1 and 78–390 mg K+ l−1 for the total nitrogen and potassium determinations, respectively.

Atividades financiadas

Não foram encontrados projetos financiados.