Publicação

Iron speciation by microsequential injection solid phase spectrometry using 3-hydroxy-1(H)-2-methyl-4-pyridinone as chromogenic reagent

Ver documento

Detalhes bibliográficos
Resumo:The speciation of iron using the newly synthesized 3-hydroxy-1(H)-2-methyl-4-pyridinone by solid phase spectrophotometry in a microsequential injection lab-on-valve (µSI-LOV-SPS) methodology is described. Iron was retained in a reusable column, Nitrilotriacetic Acid Superflow (NTA) resin, and the ligand was used as both chromogenic and eluting reagent. This approach, analyte retention and matrix removal, enabled the assessment of iron (III) and total iron content in fresh waters and high salinity coastal waters with direct sample introduction, in the range of 20.0–100 µg/L. with a LOD of 9 µg/L. The overall effluent production was 2 mL, corresponding to the consumption of 0.48 µg of 2-metil-3-hydroxy-4-pyridinone, 0.34 mg of NaHCO3, 16 mg of HNO3, 4.4 µg H2O2 and 400 µL of sample. Four reference samples were analyzed and a relative deviation<10% was obtained; furthermore, several bathing waters (♯13) were analyzed using the developed method and the results were comparable to those obtained by atomic absorption spectrophotometry (relative deviations<6%).
Autores principais:Suárez, Ruth
Outros Autores:Mesquita, Raquel B. R.; Rangel, Maria; Cerdà, Víctor; Rangel, António O.S.S.
Assunto:Total iron Iron(III) Solid phasespectrometry 3-Hydroxy-4-pyridinone NTAresin Lab-on-valve
Ano:2015
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:Universidade Católica Portuguesa
Idioma:inglês
Origem:Veritati - Repositório Institucional da Universidade Católica Portuguesa
Descrição
Resumo:The speciation of iron using the newly synthesized 3-hydroxy-1(H)-2-methyl-4-pyridinone by solid phase spectrophotometry in a microsequential injection lab-on-valve (µSI-LOV-SPS) methodology is described. Iron was retained in a reusable column, Nitrilotriacetic Acid Superflow (NTA) resin, and the ligand was used as both chromogenic and eluting reagent. This approach, analyte retention and matrix removal, enabled the assessment of iron (III) and total iron content in fresh waters and high salinity coastal waters with direct sample introduction, in the range of 20.0–100 µg/L. with a LOD of 9 µg/L. The overall effluent production was 2 mL, corresponding to the consumption of 0.48 µg of 2-metil-3-hydroxy-4-pyridinone, 0.34 mg of NaHCO3, 16 mg of HNO3, 4.4 µg H2O2 and 400 µL of sample. Four reference samples were analyzed and a relative deviation<10% was obtained; furthermore, several bathing waters (♯13) were analyzed using the developed method and the results were comparable to those obtained by atomic absorption spectrophotometry (relative deviations<6%).

Atividades financiadas

Carregando projetos financiados...