Sequential injection system with in-line solid phase extraction and soil minicolumn for determination of zinc and copper in soil leachates

Ver documento

Detalhes bibliográficos
Resumo:A sequential injection (SI) system equipped with in-line solid phase extraction column and in-line soil minicolumn is proposed for determination of zinc and copper in soil leachates. The spectrophotometric determination (560 nm) is based on the reaction of both analytes with 1-(2-Pyridylazo)-2-naphthol (PAN). Zinc is determined after retaining copper on a cationic resin (Chelex100) whereas copper is determined from the difference of the absorbance measured for both analytes, introduced into the system with the use of a different channel, and zinc absorbance. The influence of several potential interferences was studied. Using the developed method, zinc and copper were determined within the concentration ranges of 0.005–0.300 and 0.011–0.200 mg L−1, and with a relative standard deviation lower than 6.0% and 5.1%, respectively. The detection limits are 1.4 and 3.0 μg/L for determination of zinc and copper, respectively. The developed SI method was verified by the determination of both analytes in synthetic and certified reference materials of water samples, and applied to the determination of the analytes in rain water and soil leachates from laboratory scale soil core column and in-line soil mini-column.
Autores principais:Paluch, Justyna
Outros Autores:Mesquita, Raquel B. R.; Cerdà, Victor; Kozak, Joanna; Wieczorek, Marcin; Rangel, António O. S. S.
Assunto:Sequential injection analysis Copper Zinc Mini soil column Soil leachates
Ano:2018
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso restrito
Instituição associada:Universidade Católica Portuguesa
Idioma:inglês
Origem:Veritati - Repositório Institucional da Universidade Católica Portuguesa
Descrição
Resumo:A sequential injection (SI) system equipped with in-line solid phase extraction column and in-line soil minicolumn is proposed for determination of zinc and copper in soil leachates. The spectrophotometric determination (560 nm) is based on the reaction of both analytes with 1-(2-Pyridylazo)-2-naphthol (PAN). Zinc is determined after retaining copper on a cationic resin (Chelex100) whereas copper is determined from the difference of the absorbance measured for both analytes, introduced into the system with the use of a different channel, and zinc absorbance. The influence of several potential interferences was studied. Using the developed method, zinc and copper were determined within the concentration ranges of 0.005–0.300 and 0.011–0.200 mg L−1, and with a relative standard deviation lower than 6.0% and 5.1%, respectively. The detection limits are 1.4 and 3.0 μg/L for determination of zinc and copper, respectively. The developed SI method was verified by the determination of both analytes in synthetic and certified reference materials of water samples, and applied to the determination of the analytes in rain water and soil leachates from laboratory scale soil core column and in-line soil mini-column.