Publicação

Spectrophotometric determination of zinc and copper in a multisyringe injection analysis system using a liquid waveguide capillary cell: Application to natural waters

Ver documento

Detalhes bibliográficos
Resumo:This work exploits a multisyringe injection analysis (MSFIA) system coupled with a long liquid waveguide capillary cell for the spectrophotometric determination of zinc and copper in waters. A liquid waveguide capillary cell (1.0mpathlength, 550mmi.d. and 250mL internal volume) was used to enhance the sensitivity of the detection. The determination for both ions is based on a colorimetric reaction with zincon at different pH values. The developed methodology compares favourably with other previously described procedures, as it allows to reach low detection limits for both cations (LODs of 0.1 and 2mg L−1, for copper and zinc, respectively), without the need for any preconcentration step. The system also provided a linear response up to 100mg L−1 with a high throughput (43 h−1) and low reagent consumption and effluent production. The developed work was applied to natural waters and three certified reference water samples.
Autores principais:Páscoa, Ricardo N. M. J.
Outros Autores:Tóth, Ildikó V.; Rangel, António O. S. S.
Assunto:Copper Zinc Multisyringe Liquid waveguide capillary cell Spectrophotometry Natural waters
Ano:2011
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso restrito
Instituição associada:Universidade Católica Portuguesa
Idioma:inglês
Origem:Veritati - Repositório Institucional da Universidade Católica Portuguesa
Descrição
Resumo:This work exploits a multisyringe injection analysis (MSFIA) system coupled with a long liquid waveguide capillary cell for the spectrophotometric determination of zinc and copper in waters. A liquid waveguide capillary cell (1.0mpathlength, 550mmi.d. and 250mL internal volume) was used to enhance the sensitivity of the detection. The determination for both ions is based on a colorimetric reaction with zincon at different pH values. The developed methodology compares favourably with other previously described procedures, as it allows to reach low detection limits for both cations (LODs of 0.1 and 2mg L−1, for copper and zinc, respectively), without the need for any preconcentration step. The system also provided a linear response up to 100mg L−1 with a high throughput (43 h−1) and low reagent consumption and effluent production. The developed work was applied to natural waters and three certified reference water samples.

Atividades financiadas

Não foram encontrados projetos financiados.