Publication

New microfluidic paper-based analytical device for iron determination in urine samples

View document

Bibliographic Details
Summary:Iron is an important micronutrient involved in several mechanisms in the human body and can be an important biomarker. In this work, a simple and disposable microfluidic paper-based analytical device (µPAD) was developed for the quantification of iron in urine samples. The detection was based on the colorimetric reaction between iron(II) and bathophenanthroline and the reduction of iron(III) to iron(II) with hydroxylamine. The developed µPAD enabled iron determination in the range 0.07–1.2 mg/L, with a limit of detection of 20 µg/L and a limit of quantification of 65 µg/L, thus suitable for the expected values in human urine. Additionally, targeting urine samples, the potential interference of the samples color was overcome by incorporating a sample blank assessment for absorbance subtraction. Stability studies revealed that the device was stable for 15 days prior to usage and that the formed colored product was stable for scanning up to 3 h. The accuracy of the developed device was established by analyzing urine samples (#26) with the developed µPAD and with the atomic absorption spectrometry method; the relative deviation between the two sets of results was below 9.5%. Graphical abstract: [Figure not available: see fulltext.]
Main Authors:Ferreira, Francisca T. S. M.
Other Authors:Catalão, Karina A.; Mesquita, Raquel B. R.; Rangel, António O. S. S.
Subject:Bathophenanthroline reaction Biological samples Disposable device Iron(II) and iron(III) content Paper sensor Sample blank correction
Year:2021
Country:Portugal
Document type:article
Access type:open access
Associated institution:Universidade Católica Portuguesa
Language:English
Origin:Veritati - Repositório Institucional da Universidade Católica Portuguesa
Description
Summary:Iron is an important micronutrient involved in several mechanisms in the human body and can be an important biomarker. In this work, a simple and disposable microfluidic paper-based analytical device (µPAD) was developed for the quantification of iron in urine samples. The detection was based on the colorimetric reaction between iron(II) and bathophenanthroline and the reduction of iron(III) to iron(II) with hydroxylamine. The developed µPAD enabled iron determination in the range 0.07–1.2 mg/L, with a limit of detection of 20 µg/L and a limit of quantification of 65 µg/L, thus suitable for the expected values in human urine. Additionally, targeting urine samples, the potential interference of the samples color was overcome by incorporating a sample blank assessment for absorbance subtraction. Stability studies revealed that the device was stable for 15 days prior to usage and that the formed colored product was stable for scanning up to 3 h. The accuracy of the developed device was established by analyzing urine samples (#26) with the developed µPAD and with the atomic absorption spectrometry method; the relative deviation between the two sets of results was below 9.5%. Graphical abstract: [Figure not available: see fulltext.]

Funded activities