Evaluation of In-place Concrete Strength by Near-to-surface Tests

Ver documento

Detalhes bibliográficos
Resumo:The near-to-surface tests, as described by British Standard BS 1881: Part 207: 1992, comprises different techniques which were developed to evaluate in-situ strength of concrete, and it includes: internal fracture, pull-out, pull-off, penetration resistance and break-off tests. Since these tests measure only a property of concrete close to the surface, the evaluation of in-situ strength of concrete mass has to be obtain by a experimentally correlation between the near-to surface test results and the compressive strength of concrete mass. This paper discusses the reliability of two of this techniques, penetration resistance test and pull-out tests, as a construction tool for the evaluation of the in-place concrete strength both in normal and high strength concrete. For penetration resistance test applied to high-strength concrete an alternative firing apparatus to the standard apparatus, Windsor Probe Test System, is used. The obtained correlations are also presented and compared to those obtain by other research works.
Autores principais:Lopes, Sérgio Manuel Rodrigues
Outros Autores:Nepomuceno, Miguel
Assunto:Penetration Resistance test Windsor Probe Test System Pull-out test Capo-test Normal Strength Concrete High Strength Concrete In-place testing
Ano:1998
País:Portugal
Tipo de documento:documento de conferência
Tipo de acesso:acesso aberto
Instituição associada:Universidade da Beira Interior
Idioma:inglês
Origem:uBibliorum
Descrição
Resumo:The near-to-surface tests, as described by British Standard BS 1881: Part 207: 1992, comprises different techniques which were developed to evaluate in-situ strength of concrete, and it includes: internal fracture, pull-out, pull-off, penetration resistance and break-off tests. Since these tests measure only a property of concrete close to the surface, the evaluation of in-situ strength of concrete mass has to be obtain by a experimentally correlation between the near-to surface test results and the compressive strength of concrete mass. This paper discusses the reliability of two of this techniques, penetration resistance test and pull-out tests, as a construction tool for the evaluation of the in-place concrete strength both in normal and high strength concrete. For penetration resistance test applied to high-strength concrete an alternative firing apparatus to the standard apparatus, Windsor Probe Test System, is used. The obtained correlations are also presented and compared to those obtain by other research works.

Atividades financiadas

Não foram encontrados projetos financiados.