Publicação
ALLERGIC CONTACT DERMATITIS TO ARTHROPLASTIES - A RARITY OR A SUBDIAGNOSED ENTITY?
| Resumo: | Introduction: Allergic contact dermatitis to the constituents of the prosthesis occurs in 5% of patients and may be the etiology of the failure of arthroplasty. The most common sensitizer’s metals are nickel, cobalt and chromium. The components of the cement have also been implicated as allergens.Methods: A retrospective study of patients with arthroplasties, who performed patch tests, after suspicion of allergic contact dermatitis in the last 2 years was done. We carried out tests with the standard battery of the Portuguese Group for the Study of Contact dermatitis and supplemental batteries, including metals, acrylates/methacrylates and topical antibiotics.Results: Fourteen patients were included: 10 underwent knee arthroplasty, 3 hip arthroplasty and 1 ankle arthroplasty. Patients had limited function of joints. The mean age of patients observed was 61.6 years and 12 patients were females and 2 males. The symptoms appeared on average 14.4 months after surgery. Nine patients had positive reactions to nickel, 5 to cobalt, 1 to chromium, 1 to gentamicin and neomycin. In these cases we opted for placing the prosthesis revision with oxinium and/or titanium, with improvement of symptomatology.Discussion and conclusions: This review showed the importance of performing patch tests in patients with clinical signs of failure of arthroplasty, since patients with sensitization to its constituent improved with the replacement of prosthesis. |
|---|---|
| Autores principais: | Resende, Cristina |
| Outros Autores: | Santos, R.; Pereira, T.; Araújo, C.; Tavares, N.; Brito, C. |
| Assunto: | Arthroplasty replacement Dermatitis allergic contact Patch tests Artroplastia de substituição Dermatite alérgica de contacto Testes epicutâneos |
| Ano: | 2015 |
| País: | Portugal |
| Tipo de documento: | artigo |
| Instituição associada: | Sociedade Portuguesa de Dermatologia e Venereologia |
| Idioma: | português |
| Origem: | Portuguese Journal of Dermatology |
| Resumo: | Introduction: Allergic contact dermatitis to the constituents of the prosthesis occurs in 5% of patients and may be the etiology of the failure of arthroplasty. The most common sensitizer’s metals are nickel, cobalt and chromium. The components of the cement have also been implicated as allergens.Methods: A retrospective study of patients with arthroplasties, who performed patch tests, after suspicion of allergic contact dermatitis in the last 2 years was done. We carried out tests with the standard battery of the Portuguese Group for the Study of Contact dermatitis and supplemental batteries, including metals, acrylates/methacrylates and topical antibiotics.Results: Fourteen patients were included: 10 underwent knee arthroplasty, 3 hip arthroplasty and 1 ankle arthroplasty. Patients had limited function of joints. The mean age of patients observed was 61.6 years and 12 patients were females and 2 males. The symptoms appeared on average 14.4 months after surgery. Nine patients had positive reactions to nickel, 5 to cobalt, 1 to chromium, 1 to gentamicin and neomycin. In these cases we opted for placing the prosthesis revision with oxinium and/or titanium, with improvement of symptomatology.Discussion and conclusions: This review showed the importance of performing patch tests in patients with clinical signs of failure of arthroplasty, since patients with sensitization to its constituent improved with the replacement of prosthesis. |
|---|
Atividades financiadas