Publicação
Evaluation of MCM-41 and MCM-48 mesoporous materials as sorbents in matrix solid phase dispersion method for the determination of pesticides in soursop fruit (Annona muricata)
| Resumo: | The MCM-41 and MCM-48 mesoporous materials were tested for extraction of thiamethoxam, thiacloprid, thiophanate-methyl, teflubenzuron, and bifenthrin from the fruit of soursop (Annona muricata), using liquid chromatography with ultraviolet diode array detection as the analysis technique. Extractions performed at one fortification level (0.5 mg kg−1, n = 3) resulted in recoveries in the ranges 75–106% and 76–95% for MCM-41 and MCM-48, respectively, with relative standard deviations (n = 3) ranging from 5 to 9%. The detection and quantification limits for the pesticides studied were in the ranges of 0.02–0.06 mg kg−1 and 0.05–0.10 mg kg−1. The developed method was linear over the concentration range tested (0.01–5 mg kg−1), with correlation coefficients of between 0.9620 and 0.9999. Comparison of the mesoporous materials and a conventional sorbent (Florisil) revealed a similar performance for the pesticides. |
|---|---|
| Autores principais: | Santos, Luís Fabrício Santana |
| Outros Autores: | de Jesus, Roberta Anjos; Costa, José Arnaldo Santana; Gouveia, Lucas Gabriel Teixeira; de Mesquita, Maria Eliane; Navickiene, Sandro |
| Assunto: | Annona muricata MSPD Mesoporous material Pesticides Soursop |
| Ano: | 2019 |
| País: | Portugal |
| Tipo de documento: | artigo |
| Tipo de acesso: | acesso aberto |
| Instituição associada: | Universidade de Aveiro |
| Idioma: | inglês |
| Origem: | RIA - Repositório Institucional da Universidade de Aveiro |
| Resumo: | The MCM-41 and MCM-48 mesoporous materials were tested for extraction of thiamethoxam, thiacloprid, thiophanate-methyl, teflubenzuron, and bifenthrin from the fruit of soursop (Annona muricata), using liquid chromatography with ultraviolet diode array detection as the analysis technique. Extractions performed at one fortification level (0.5 mg kg−1, n = 3) resulted in recoveries in the ranges 75–106% and 76–95% for MCM-41 and MCM-48, respectively, with relative standard deviations (n = 3) ranging from 5 to 9%. The detection and quantification limits for the pesticides studied were in the ranges of 0.02–0.06 mg kg−1 and 0.05–0.10 mg kg−1. The developed method was linear over the concentration range tested (0.01–5 mg kg−1), with correlation coefficients of between 0.9620 and 0.9999. Comparison of the mesoporous materials and a conventional sorbent (Florisil) revealed a similar performance for the pesticides. |
|---|
Atividades financiadas
Não foram encontrados projetos financiados.