Publicação

Reliability of measuring pectoralis minor muscle resting length in subjects with and without signs of shoulder impingement

Ver documento

Detalhes bibliográficos
Resumo:Background: Pectoralis minor adaptive shortening may change scapula resting position and scapular kinematics during arm elevation. A reliable and clinically feasible method for measuring pectoralis minor length will be useful for clinical decision making when evaluating and treating individuals with shoulder pain and dysfunction. Objectives: To evaluate intrarater, interrater, and between-day reliability of a pectoralis minor (PM) muscle length measurement in subjects with and without signs of shoulder impingement. Method: A convenience sample of 100 individuals (50 asymptomatic and 50 symptomatic) participated in this study. Intra- and interrater reliability of the measurement was estimated in 50 individuals (25 asymptomatic and 25 symptomatic), and between-day reliability of the measurement repeated over an interval of 7 days was estimated in an independent sample of 50 additional participants. Pectoralis minor length was measured using a flexible tape measure with subjects standing. Results: Intraclass correlation coefficients (ICC3,k) for intrarater and interrater reliability ranged from 0.86-0.97 and 0.95 for between-day reliability in both groups. Standard error of measurements (SEM) ranged from 0.30-0.42 cm, 0.70-0.84 cm, and 0.40-0.41 cm for intrarater, interrater, and between-day reliability, respectively, across the sample. The minimal detectable change (MDC) for between-day measurements ranged from 1.13-1.14 cm for both groups. Conclusions: In asymptomatic individuals and in those with signs of shoulder impingement, a single rater or pair of raters can measure pectoralis minor muscle length using a tape measure with very good reliability. This measurement can also be reliably used by the same rater over a seven day interval.
Autores principais:Rosa,Dayana P.
Outros Autores:Borstad,John D.; Pires,Elisa D.; Camargo,Paula R.
Assunto:measurement scapula physical therapy tightness
Ano:2016
País:Brasil
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:IBICT
Idioma:inglês
Origem:Oasisbr
Descrição
Resumo:Background: Pectoralis minor adaptive shortening may change scapula resting position and scapular kinematics during arm elevation. A reliable and clinically feasible method for measuring pectoralis minor length will be useful for clinical decision making when evaluating and treating individuals with shoulder pain and dysfunction. Objectives: To evaluate intrarater, interrater, and between-day reliability of a pectoralis minor (PM) muscle length measurement in subjects with and without signs of shoulder impingement. Method: A convenience sample of 100 individuals (50 asymptomatic and 50 symptomatic) participated in this study. Intra- and interrater reliability of the measurement was estimated in 50 individuals (25 asymptomatic and 25 symptomatic), and between-day reliability of the measurement repeated over an interval of 7 days was estimated in an independent sample of 50 additional participants. Pectoralis minor length was measured using a flexible tape measure with subjects standing. Results: Intraclass correlation coefficients (ICC3,k) for intrarater and interrater reliability ranged from 0.86-0.97 and 0.95 for between-day reliability in both groups. Standard error of measurements (SEM) ranged from 0.30-0.42 cm, 0.70-0.84 cm, and 0.40-0.41 cm for intrarater, interrater, and between-day reliability, respectively, across the sample. The minimal detectable change (MDC) for between-day measurements ranged from 1.13-1.14 cm for both groups. Conclusions: In asymptomatic individuals and in those with signs of shoulder impingement, a single rater or pair of raters can measure pectoralis minor muscle length using a tape measure with very good reliability. This measurement can also be reliably used by the same rater over a seven day interval.

Atividades financiadas

Não foram encontrados projetos financiados.