Publicação

Voltammetric behavior of a modified electrode with azide copper octa(3-aminopropyl)octasilsesquioxane composite in the oxidation of ascorbic acid

Ver documento

Detalhes bibliográficos
Resumo:A novel nanostructured composite, azide copper octa (3-aminopropyl)octasilsesquioxane (ASCA) was incorporated into a graphite paste electrode and the electrochemical studies were conducted with cyclic voltammetry. The cyclic voltammogram of the modified graphite paste electrode with ASCA (GPE-ASCA), showed one redox couple with formal potential (Eθ) = 0.30 V and an irreversible process at 1.1 V (vs Ag/AgCl; NaCl 1.0 mol L-1; v = 20 mV s-1). The redox couple with (Eθ) = 0.30V presents an electrocatalytic response for determination of ascorbic acid. The modified electrode gives a linear range from 1.0×10-4 -1.0×10-3 mol L-1 (r = 0.998) for the determination of ascorbic acid with detection limit of 6.9×10-5 mol L-1 and standard deviation of 2.3% for n = 3. The amperometric sensitivity was 122.1 mA/mol L-1 for ascorbic acid. The application this electrode was tested and ascorbic acid in three commercial pharmaceutical product (Cebion, Cewin and Redoxon) have been determined. © 2011 by ESG.
Autores principais:do Carmo, Devaney Ribeiro
Outros Autores:Paim, Leonardo Lataro; Silvestrini, Daniela Rodrigues; de Sá, Acelino Cardoso; de Oliveira Bicalho, Urquisa; Stradiotto, Nelson Ramos
Assunto:Ascorbic acid Graphite paste electrode Modified electrode Silsesquioxane Voltammetry
Ano:2022
País:Brasil
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:IBICT
Idioma:inglês
Origem:Oasisbr
Descrição
Resumo:A novel nanostructured composite, azide copper octa (3-aminopropyl)octasilsesquioxane (ASCA) was incorporated into a graphite paste electrode and the electrochemical studies were conducted with cyclic voltammetry. The cyclic voltammogram of the modified graphite paste electrode with ASCA (GPE-ASCA), showed one redox couple with formal potential (Eθ) = 0.30 V and an irreversible process at 1.1 V (vs Ag/AgCl; NaCl 1.0 mol L-1; v = 20 mV s-1). The redox couple with (Eθ) = 0.30V presents an electrocatalytic response for determination of ascorbic acid. The modified electrode gives a linear range from 1.0×10-4 -1.0×10-3 mol L-1 (r = 0.998) for the determination of ascorbic acid with detection limit of 6.9×10-5 mol L-1 and standard deviation of 2.3% for n = 3. The amperometric sensitivity was 122.1 mA/mol L-1 for ascorbic acid. The application this electrode was tested and ascorbic acid in three commercial pharmaceutical product (Cebion, Cewin and Redoxon) have been determined. © 2011 by ESG.

Atividades financiadas

Não foram encontrados projetos financiados.