Publicação

Electrochemical degradation of dimethyl phthalate ester on a DSA® electrode

Ver documento

Detalhes bibliográficos
Resumo:The electrochemical degradation of dimethyl phthalate (DMP) using a one-compartment filter press flow cell and a commercial dimensionally stable anode (DSA®) is presented. The best electrolysis conditions were determined by the analysis of the influence of the nature and concentration of the support electrolyte, pH, current density and temperature. The abatement of DMP concentration and total organic carbon (TOC) removal were superior in the presence of NaCl, as well as the apparent first order kinetic constants. Using constant ionic strength at 0.15 mol dm-3 by adding Na2SO4, DMP concentration decreases faster at relative low NaCl concentrations while the TOC removal after 1 h of electrolysis increases with NaCl concentration. The DMP removal was very similar for all the current densities investigated at acidic solutions. When electric energy saving is considered, since the electrochemical system was under mass transport conditions, the best operational option is to use low current density values.
Autores principais:Souza,Fernanda L.
Outros Autores:Aquino,José M.; Miwa,Douglas W.; Rodrigo,Manuel A.; Motheo,Artur J.
Assunto:endocrine disruptor dimethyl phthalate indirect oxidation electrooxidation mass-transport
Ano:2014
País:Brasil
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:IBICT
Idioma:inglês
Origem:Oasisbr
Descrição
Resumo:The electrochemical degradation of dimethyl phthalate (DMP) using a one-compartment filter press flow cell and a commercial dimensionally stable anode (DSA®) is presented. The best electrolysis conditions were determined by the analysis of the influence of the nature and concentration of the support electrolyte, pH, current density and temperature. The abatement of DMP concentration and total organic carbon (TOC) removal were superior in the presence of NaCl, as well as the apparent first order kinetic constants. Using constant ionic strength at 0.15 mol dm-3 by adding Na2SO4, DMP concentration decreases faster at relative low NaCl concentrations while the TOC removal after 1 h of electrolysis increases with NaCl concentration. The DMP removal was very similar for all the current densities investigated at acidic solutions. When electric energy saving is considered, since the electrochemical system was under mass transport conditions, the best operational option is to use low current density values.

Atividades financiadas

Não foram encontrados projetos financiados.