Publication
Multiresidue determination of pesticides in carrots using pressurized liquid extraction and gas chromatography with mass spectrometry detector
| Summary: | In this study, 14 pesticides (captan, chlorothalonil, deltamethrin, dicloran, fenthion, folpet, iprodione, linuron, malathion, prometryn, prochloraz, procymidone, trichlorphon and trifluralin) were employed for developing a multiresidue method (MRM) using pressurized liquid extraction (PLE). In situ clean-up was achieved using matrix solid phase dispersion (MSPD), where Florisil, XAD-4, XAD-7 and C18 were tested as dispersing material for carrot samples. Dichloromethane, ethyl acetate and acetone were used as solvents in a PLE unit at 75 ºC and 1,500 psi. Recovery was in the range of 70 to 133 %. Results obtained with wet carrots were not satisfactory, since most of the recovery values were below 70%. Determination coefficients of the analytical curves presented values between 0.9821 and 0.9970. Limits of detection (LOD) and quantification (LOQ) for the various components varied from 0.0024 to 0.1968 mg kg-1, and 0.0072 to 0.5963 mg kg-1, respectively. |
|---|---|
| Main Authors: | Abad,Fernanda C. |
| Other Authors: | Winck,Priscila R.; Silva,Juliana M. da; Caramão,Elina B.; Zini,Cláudia A. |
| Subject: | multiresidue method PLE MSPD carrots GC/MS |
| Year: | 2010 |
| Country: | Brazil |
| Document type: | article |
| Access type: | open access |
| Associated institution: | IBICT |
| Language: | English |
| Origin: | Oasisbr |
| Summary: | In this study, 14 pesticides (captan, chlorothalonil, deltamethrin, dicloran, fenthion, folpet, iprodione, linuron, malathion, prometryn, prochloraz, procymidone, trichlorphon and trifluralin) were employed for developing a multiresidue method (MRM) using pressurized liquid extraction (PLE). In situ clean-up was achieved using matrix solid phase dispersion (MSPD), where Florisil, XAD-4, XAD-7 and C18 were tested as dispersing material for carrot samples. Dichloromethane, ethyl acetate and acetone were used as solvents in a PLE unit at 75 ºC and 1,500 psi. Recovery was in the range of 70 to 133 %. Results obtained with wet carrots were not satisfactory, since most of the recovery values were below 70%. Determination coefficients of the analytical curves presented values between 0.9821 and 0.9970. Limits of detection (LOD) and quantification (LOQ) for the various components varied from 0.0024 to 0.1968 mg kg-1, and 0.0072 to 0.5963 mg kg-1, respectively. |
|---|
Funded activities
No funded projects found.