Publicação

Tomographic Analysis of the Anatomical Parameters for the Insertion of Cortical Bone Screws

Ver documento

Detalhes bibliográficos
Resumo:Abstract Objective To study the parameters related to the insertion path of cortical screws and to describe this technique. Methods Computed tomography (CT) scans of 30 patients, as well as the measurements from the L1 to the L5 vertebrae, were studied. A second observer evaluated ten randomly-selected exams. The parameters studied included the lateral angle (LA) and the screw diameter (SD) as axial variables, and the cranial angle (CA) and screw length (SL) as sagittal variables. Results We studied 15 male patients (mean age: 31.33 years) and 15 female patients (mean age: 32.01 years). The LA varied between 13.8° and 20.89°, with a tendency to increase in the proximal to distal direction. The CA varied from 17.5° to 24.9°, with a tendency to decrease in the caudal direction. The SD ranged from 2.3 mm to 7.2 mm, with a tendency to increase as we progressed from proximal to distal. The SL varied from 19 mm to 45 mm, with a tendency to decrease as we proceeded from proximal (L1) to distal (L5). No statistical difference was observed between the genders or in the interobserver agreement regarding the values studied when comparing the sides. Conclusion The path of insertion of the cortical screw shows a variation in different populations. Therefore, we recommend a preoperative imaging study to reduce the surgical risks related to the technique.
Autores principais:Herrero,Carlos Fernando Pereira da Silva
Outros Autores:Marangoni,Rafael Campos Fróes
Assunto:spine minimally invasive surgical procedures bone screws
Ano:2022
País:Brasil
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:IBICT
Idioma:inglês
Origem:Oasisbr
Descrição
Resumo:Abstract Objective To study the parameters related to the insertion path of cortical screws and to describe this technique. Methods Computed tomography (CT) scans of 30 patients, as well as the measurements from the L1 to the L5 vertebrae, were studied. A second observer evaluated ten randomly-selected exams. The parameters studied included the lateral angle (LA) and the screw diameter (SD) as axial variables, and the cranial angle (CA) and screw length (SL) as sagittal variables. Results We studied 15 male patients (mean age: 31.33 years) and 15 female patients (mean age: 32.01 years). The LA varied between 13.8° and 20.89°, with a tendency to increase in the proximal to distal direction. The CA varied from 17.5° to 24.9°, with a tendency to decrease in the caudal direction. The SD ranged from 2.3 mm to 7.2 mm, with a tendency to increase as we progressed from proximal to distal. The SL varied from 19 mm to 45 mm, with a tendency to decrease as we proceeded from proximal (L1) to distal (L5). No statistical difference was observed between the genders or in the interobserver agreement regarding the values studied when comparing the sides. Conclusion The path of insertion of the cortical screw shows a variation in different populations. Therefore, we recommend a preoperative imaging study to reduce the surgical risks related to the technique.

Atividades financiadas

Não foram encontrados projetos financiados.