Publicação

Ex vivo evaluation of three instrumentation techniques on E. faecalis biofilm within oval shaped root canals

Ver documento

Detalhes bibliográficos
Resumo:The objective of the present study was to assess the effectiveness of reciprocating instrumentation in disinfecting oval-shaped root canals infected with Enterococcus faecalis. Forty-five human lower premolars were infected with a culture of E. faecalis (ATCC 29212) for 28 days. Five other teeth that were neither contaminated nor instrumented were used as controls. The 45 specimens were divided into three experimental groups (n = 15) based on the root canal preparation technique used: manual (K-type, Dentsply Maillefer, Ballaigues, Switzerland); rotary (MTwo, VDW GmbH, Munich, Germany); and reciprocating (Reciproc R50, VDW GmbH, Munich, Germany) instruments. During chemomechanical preparation, 21 mL of 2.5% NaOCl was used as the irrigating solution. Microbiological sampling was performed before (S1) and immediately after (S2) the chemomechanical preparation using sterilized paper points. Specimens were then cleaved, and 0.02 g of dentine chips was collected from the root thirds to verify the presence of microorganisms in dentinal tubules. All three preparation techniques reduced the number of microorganisms in the root canal lumen and dentine chips from the root thirds, but no significant differences were observed between the three groups (p > 0.05). Reciprocating instrumentation with Reciproc R50 was effective in reducing the number of microorganisms within the root canal system. Although this technique involves the use of only one file to perform the root canal therapy, it is as effective as conventional rotary instrumentation in reducing theE. faecalis biofilm from the root canal system. However, further clinical investigations are warranted in order to ratify these results.
Autores principais:NAKAMURA,Vitor Cesar
Outros Autores:CANDEIRO,George Taccio de Miranda; CAI,Silvana; GAVINI,Giulio
Assunto:Endodontics Root Canal Preparation Root Canal Therapy Dental Instruments
Ano:2015
País:Brasil
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:IBICT
Idioma:inglês
Origem:Oasisbr
Descrição
Resumo:The objective of the present study was to assess the effectiveness of reciprocating instrumentation in disinfecting oval-shaped root canals infected with Enterococcus faecalis. Forty-five human lower premolars were infected with a culture of E. faecalis (ATCC 29212) for 28 days. Five other teeth that were neither contaminated nor instrumented were used as controls. The 45 specimens were divided into three experimental groups (n = 15) based on the root canal preparation technique used: manual (K-type, Dentsply Maillefer, Ballaigues, Switzerland); rotary (MTwo, VDW GmbH, Munich, Germany); and reciprocating (Reciproc R50, VDW GmbH, Munich, Germany) instruments. During chemomechanical preparation, 21 mL of 2.5% NaOCl was used as the irrigating solution. Microbiological sampling was performed before (S1) and immediately after (S2) the chemomechanical preparation using sterilized paper points. Specimens were then cleaved, and 0.02 g of dentine chips was collected from the root thirds to verify the presence of microorganisms in dentinal tubules. All three preparation techniques reduced the number of microorganisms in the root canal lumen and dentine chips from the root thirds, but no significant differences were observed between the three groups (p > 0.05). Reciprocating instrumentation with Reciproc R50 was effective in reducing the number of microorganisms within the root canal system. Although this technique involves the use of only one file to perform the root canal therapy, it is as effective as conventional rotary instrumentation in reducing theE. faecalis biofilm from the root canal system. However, further clinical investigations are warranted in order to ratify these results.

Atividades financiadas

Não foram encontrados projetos financiados.