SPECIATION ANALYSIS OF ARSENIC IN RICE USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY COUPLED WITH HYDRIDE GENERATION ATOMIC FLUORESCENCE SPECTROMETRY (HPLC-HG-AFS)
| Resumo: | The aim of this work was to develop a method using high performance liquid chromatography coupled with hydride generation atomic fluorescence spectrometry (HPLC-HG-AFS) for the determination and speciation analysis of the inorganic and organic species of arsenic found most often in rice samples: As(V), As(III), monomethylarsonic acid (MMA), and dimethylarsinic acid (DMA). The best chromatographic resolution was obtained using pH 6.2, a phosphate buffer mobile phase concentration of 20 mmol L-1 and flow rate of 0.57 mL min-1, HCl concentration of 5.55% (v/v), and NaBH4 concentration of 0.90% (w/v). The accuracy of the method was confirmed by the low relative error values obtained for analysis of a certified reference material (NIST 1568b): 6.63% (total inorganic As), 3.44% (DMA), 0% (MMA), and 0.53% (total As). In recovery tests, the proposed method achieved satisfactory recoveries in the range 86-110%. |
|---|---|
| Autores principais: | Borges,Gabriella A. |
| Outros Autores: | Souza,Guilhermina de O.; Lopes,Patrícia S. F.; Ciminelli,Virginia S. T.; Caldeira,Claudia L.; Rodrigues,Guilherme D. |
| Assunto: | speciation analysis arsenic rice |
| Ano: | 2020 |
| País: | Brasil |
| Tipo de documento: | artigo |
| Tipo de acesso: | acesso aberto |
| Instituição associada: | IBICT |
| Idioma: | inglês |
| Origem: | Oasisbr |
| Resumo: | The aim of this work was to develop a method using high performance liquid chromatography coupled with hydride generation atomic fluorescence spectrometry (HPLC-HG-AFS) for the determination and speciation analysis of the inorganic and organic species of arsenic found most often in rice samples: As(V), As(III), monomethylarsonic acid (MMA), and dimethylarsinic acid (DMA). The best chromatographic resolution was obtained using pH 6.2, a phosphate buffer mobile phase concentration of 20 mmol L-1 and flow rate of 0.57 mL min-1, HCl concentration of 5.55% (v/v), and NaBH4 concentration of 0.90% (w/v). The accuracy of the method was confirmed by the low relative error values obtained for analysis of a certified reference material (NIST 1568b): 6.63% (total inorganic As), 3.44% (DMA), 0% (MMA), and 0.53% (total As). In recovery tests, the proposed method achieved satisfactory recoveries in the range 86-110%. |
|---|
Atividades financiadas
Não foram encontrados projetos financiados.