Evaluation of microbial contamination in multi-dose fluorescein eyedrops in a reference eye center

Ver documento

Detalhes bibliográficos
Resumo:ABSTRACT Purpose: To analyze the presence of microorganisms in fluorescein eyedrops used in a reference eye center in Recife-PE. Methods: This real-life and masked study evaluated fluorescein eyedrops used at the Altino Ventura Foundation in May 2019. Cultures were performed according to exposure times; I) three eyedrop bottles were analyzed after one day of use, II) three eyedrop bottles after 4 d of use, III) three eyedrop bottles after 8 d of use, and IV) three unopened bottles used as control. Samples were collected from the bottle’s tip, instilled drop, and residual fluid. After incubation, all colonies were analyzed and identified through biochemical tests. Results: The contamination rate of the fluorescein eyedrop bottles in this study was 55.5% (5/9 vials). There was no contamination in the control group. The highest contamination was seen in one day exposed eyedrops, in 100% of the bottles. The bottle’s tip had a higher rate of contamination compared to the drop and residual fluid. Gram-positive bacteria were isolated in 7/27 (25.9%) samples. Growth of fungi or gram-negative bacteria was not observed. Conclusion: The identification of gram-positive bacteria predominantly on the tip of the fluorescein eyedrop bottles suggests inadequate handling as the main cause of contamination.
Autores principais:Costa,Camila de Moraes
Outros Autores:Espósito,Kayo Pinheiro; Florêncio,Victor Medeiros Brandão; Aquino,Paulo Romero Leite; Firmo,Elza Ferreira; Costa,Iggor Macêdo do Amaral; Rocha,Camilla; Andrade,Camila Galvão de; Oliveira-Júnior,Jorge Belém; Ventura,Camila V.
Assunto:Fluorescein Ophthalmic solution Drug contamination Eye infection, bacterial/microbiology Bacteria/isolation & purification
Ano:2021
País:Brasil
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:IBICT
Idioma:inglês
Origem:Oasisbr
Descrição
Resumo:ABSTRACT Purpose: To analyze the presence of microorganisms in fluorescein eyedrops used in a reference eye center in Recife-PE. Methods: This real-life and masked study evaluated fluorescein eyedrops used at the Altino Ventura Foundation in May 2019. Cultures were performed according to exposure times; I) three eyedrop bottles were analyzed after one day of use, II) three eyedrop bottles after 4 d of use, III) three eyedrop bottles after 8 d of use, and IV) three unopened bottles used as control. Samples were collected from the bottle’s tip, instilled drop, and residual fluid. After incubation, all colonies were analyzed and identified through biochemical tests. Results: The contamination rate of the fluorescein eyedrop bottles in this study was 55.5% (5/9 vials). There was no contamination in the control group. The highest contamination was seen in one day exposed eyedrops, in 100% of the bottles. The bottle’s tip had a higher rate of contamination compared to the drop and residual fluid. Gram-positive bacteria were isolated in 7/27 (25.9%) samples. Growth of fungi or gram-negative bacteria was not observed. Conclusion: The identification of gram-positive bacteria predominantly on the tip of the fluorescein eyedrop bottles suggests inadequate handling as the main cause of contamination.