Publicação

Synthesis of Poly(Vinylferrocene) Perchlorate/Poly(3,3’-Diaminobenzidine) Modified Electrode in Dichloromethane for Electroanalysis of Hydroquinone

Ver documento

Detalhes bibliográficos
Resumo:Poly(vinylferrocenium) perchlorate-poly(3,3’-diaminobenzidine) (PVF+ClO4–-PDAB) composite film was synthesized electrochemically for the first time on Pt disc electrode in a dichloromethane solution containing poly(vinylferrocene) (PVF) polymer, 3,3’-diaminobenzidine (DAB) monomer and tetrabutylammonium perchlorate as supporting electrolyte. This modified electrode was characterized using cyclic voltammetry, Fourier transform infrared spectroscopy (FTIR), UV-Vis spectrophotometry, atomic absorption spectroscopy (AAS), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX) methods and it was used for amperometric determination of hydroquinone (HQ) at potential ranges of 0.40 and 0.60 V. The best analytical results for HQ was obtained at 0.45 V in NaHSO4/Na2SO4 solution (pH 2.0) and limit of detection, limit of quantification and linear response range were found as 7.469 × 10-5, 2.489 × 10-4 and 2.489 × 10-4-65.0 mmol L-1 (R2 = 0.996), respectively. These results were compared to poly(3,3’-diaminobenzidine) (PDAB) coated and uncoated Pt electrodes. The best analytical results were obtained with composite film because of behavior as electron transfer mediator of PVF.
Autores principais:Ülker,Emine
Outros Autores:Kavanoz,Muammer
Assunto:poly(vinylferrocene) poly(3,3’-diaminobenzidine) hydroquinone amperometric determination composite film
Ano:2015
País:Brasil
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:IBICT
Idioma:inglês
Origem:Oasisbr
Descrição
Resumo:Poly(vinylferrocenium) perchlorate-poly(3,3’-diaminobenzidine) (PVF+ClO4–-PDAB) composite film was synthesized electrochemically for the first time on Pt disc electrode in a dichloromethane solution containing poly(vinylferrocene) (PVF) polymer, 3,3’-diaminobenzidine (DAB) monomer and tetrabutylammonium perchlorate as supporting electrolyte. This modified electrode was characterized using cyclic voltammetry, Fourier transform infrared spectroscopy (FTIR), UV-Vis spectrophotometry, atomic absorption spectroscopy (AAS), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX) methods and it was used for amperometric determination of hydroquinone (HQ) at potential ranges of 0.40 and 0.60 V. The best analytical results for HQ was obtained at 0.45 V in NaHSO4/Na2SO4 solution (pH 2.0) and limit of detection, limit of quantification and linear response range were found as 7.469 × 10-5, 2.489 × 10-4 and 2.489 × 10-4-65.0 mmol L-1 (R2 = 0.996), respectively. These results were compared to poly(3,3’-diaminobenzidine) (PDAB) coated and uncoated Pt electrodes. The best analytical results were obtained with composite film because of behavior as electron transfer mediator of PVF.

Atividades financiadas