Publicação

Multivariate optimization of pressurized solvent extraction of alkylphenols and alkylphenol ethoxylates from biosolids

Ver documento

Detalhes bibliográficos
Resumo:In this study, a methodology for pressurized solvent extraction of alkylphenols (APs) and alkylphenol ethoxylates (APEOs) from biosolids was optimized by utilizing a biosolid natively containing these compounds at a high concentration level. Optimization of the extraction was carried out through a multivariate analysis experimental design with a central composite design (CCD) producing the following optimum values for the variables: temperature of 129 ºC, extraction time per cycle of 34 min in two cycles and acetone as extraction solvent. Upon comparison with Soxhlet extraction, this methodology turned out to be more efficient for the extraction of APEOs and of similar efficiency for APs. On the other hand, the methodology is considerably faster than Soxhlet and uses a smaller amount of extraction solvent. Concentrations of 204 ± 20 and 1053 ± 23 mg kg-1 for nonylphenol and nonylphenol-ethoxylate, respectively, were determined in the biosolid sample assayed.
Autores principais:Maricán,Adolfo
Outros Autores:Ahumada,Inés; Richter,Pablo
Assunto:pressurized solvent extraction biosolid alkylphenols alkylphenol ethoxylates
Ano:2012
País:Brasil
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:IBICT
Idioma:inglês
Origem:Oasisbr
Descrição
Resumo:In this study, a methodology for pressurized solvent extraction of alkylphenols (APs) and alkylphenol ethoxylates (APEOs) from biosolids was optimized by utilizing a biosolid natively containing these compounds at a high concentration level. Optimization of the extraction was carried out through a multivariate analysis experimental design with a central composite design (CCD) producing the following optimum values for the variables: temperature of 129 ºC, extraction time per cycle of 34 min in two cycles and acetone as extraction solvent. Upon comparison with Soxhlet extraction, this methodology turned out to be more efficient for the extraction of APEOs and of similar efficiency for APs. On the other hand, the methodology is considerably faster than Soxhlet and uses a smaller amount of extraction solvent. Concentrations of 204 ± 20 and 1053 ± 23 mg kg-1 for nonylphenol and nonylphenol-ethoxylate, respectively, were determined in the biosolid sample assayed.

Atividades financiadas

Não foram encontrados projetos financiados.