Publicação

Avaliação da limpeza de CDtrodo construídos a partir de CD de ouro gravável/fita adesiva de galvanoplastia

Ver documento

Detalhes bibliográficos
Resumo:Gold electrodes are widely used in electrochemistry and electroanalytical chemistry, due to the high purity, broad range of work potential as well as the possibility to control and modify the surface. On this work construction and cleaning of electrodes from gold recordables compact discs (CD-Rs), namely CDtrodes, are described. The CDs was submitted to the action of concentrated HNO3 in order to remove the protection layer and to expose the metallic layer; the electrode area was delimited by using galvanoplasty tape. The literature has been published many articles on CDtrode focused on the application but not on the cleaning; there is no register on galvanoplasty tape to define electrode area. Several methods for gold surface cleaning after attack of HNO3 were investigated, such as application of fixed potential in NaCl solution, successive scans in H2SO4 and ultrasound application, and best results were obtained in H2SO4 solution. This electrode material is interesting due to the performance comparable to the commercial electrodes, besides great versatility and low cost.
Autores principais:Foguel, M. V.
Outros Autores:Uliana, C. V.; Tomaz, P. R.U.; Marques, P. R. B. Oliveira; Yamanaka, H.; Ferreira, A. A. Pupim
Assunto:CDtrode, CD-R electrodes Cyclic voltammetry Gold surface cleaning
Ano:2022
País:Brasil
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:IBICT
Idioma:português
Origem:Oasisbr
Descrição
Resumo:Gold electrodes are widely used in electrochemistry and electroanalytical chemistry, due to the high purity, broad range of work potential as well as the possibility to control and modify the surface. On this work construction and cleaning of electrodes from gold recordables compact discs (CD-Rs), namely CDtrodes, are described. The CDs was submitted to the action of concentrated HNO3 in order to remove the protection layer and to expose the metallic layer; the electrode area was delimited by using galvanoplasty tape. The literature has been published many articles on CDtrode focused on the application but not on the cleaning; there is no register on galvanoplasty tape to define electrode area. Several methods for gold surface cleaning after attack of HNO3 were investigated, such as application of fixed potential in NaCl solution, successive scans in H2SO4 and ultrasound application, and best results were obtained in H2SO4 solution. This electrode material is interesting due to the performance comparable to the commercial electrodes, besides great versatility and low cost.

Atividades financiadas

Não foram encontrados projetos financiados.