Publicação

Hearing preservation and cochlear implants according to inner ear approach: multicentric evaluation

Ver documento

Detalhes bibliográficos
Resumo:INTRODUCTION: Electroacoustic stimulation is an excellent option for people with residual hearing in the low frequencies, who obtain insufficient benefit with hearing aids. To be effective, the subject's residual hearing should be preserved during cochlear implant surgery.OBJECTIVES: To evaluate the hearing preservation in patients that underwent implant placement and to compare the results in accordance with the approach to the inner ear.METHODS: 19 subjects underwent a soft surgical technique, and the electrode MED-EL FLEX(tm) EAS, designed to be atraumatic, was used. We evaluated pre- and postoperative tonal audiometric tests with an average of 18.4 months after implantation, to measure the rate of hearing preservation.RESULTS: 17 patients had total or partial preservation of residual hearing; 5 had total hearing preservation and two individuals had no preservation of hearing. The insertion of the electrode occurred through a cochleostomy in 3 patients, and in 2 of these there was no hearing preservation; the other 16 patients experienced electrode insertion through a round window approach. All patients benefited from the cochlear implant, even those who are only using electrical stimulation.CONCLUSION: The hearing preservation occurred in 89.4% of cases. There was no significant difference between the forms of inner ear approach.
Autores principais:Guimarães,Alexandre Caixeta
Outros Autores:Carvalho,Guilherme Machado de; Duarte,Alexandre S.M.; Bianchini,Walter A.; Sarasty,Andrea Bravo; Gregorio,Maria Fernanda di; Zernotti,Mario Emilio; Sartorato,Edi Lúcia; Castilho,Arthur Menino
Assunto:Cochlear implants Inner ear Correction of hearing impairment Bilateral hearing loss
Ano:2015
País:Brasil
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:IBICT
Idioma:inglês
Origem:Oasisbr
Descrição
Resumo:INTRODUCTION: Electroacoustic stimulation is an excellent option for people with residual hearing in the low frequencies, who obtain insufficient benefit with hearing aids. To be effective, the subject's residual hearing should be preserved during cochlear implant surgery.OBJECTIVES: To evaluate the hearing preservation in patients that underwent implant placement and to compare the results in accordance with the approach to the inner ear.METHODS: 19 subjects underwent a soft surgical technique, and the electrode MED-EL FLEX(tm) EAS, designed to be atraumatic, was used. We evaluated pre- and postoperative tonal audiometric tests with an average of 18.4 months after implantation, to measure the rate of hearing preservation.RESULTS: 17 patients had total or partial preservation of residual hearing; 5 had total hearing preservation and two individuals had no preservation of hearing. The insertion of the electrode occurred through a cochleostomy in 3 patients, and in 2 of these there was no hearing preservation; the other 16 patients experienced electrode insertion through a round window approach. All patients benefited from the cochlear implant, even those who are only using electrical stimulation.CONCLUSION: The hearing preservation occurred in 89.4% of cases. There was no significant difference between the forms of inner ear approach.

Atividades financiadas

Não foram encontrados projetos financiados.