Summary:We evaluate the results of stenting and angioplasty on carotid bifurcation stenotic lesions using protection systems, emphasizing the indications and technical aspects. Seventy-nine patients, mean age 64.5 years were treated from February,1998 to March, 2003. All patients were included in NASCET study criteria. Forty three patients were treated without the protection systems and thirty six were treated with carotid protection filtering system (Angioguard, EPI). Technical success and 6-months carotid Doppler ultrasound follow-up showing stent patency were achieved in all patients. One major stroke and one death due to intracranial reperfusion bleeding occurred in patients treated without cerebral protection devices. Only one patient presenting hyper perfusion syndrome improving after 7 days, was found in the group treated with the cerebral protection filter mechanism, no other neurologic symptom or death occured in this group. Stenting and angioplasty with protection systems for thromboembolic debris is a safe endovascular method to treat stenotic lesions in the carotid bifurcation with low morbidity and mortality.
Main Authors:Kihara,Eduardo Noda
Other Authors:Andrioli,Mario Sergio Duarte; Zukerman,Eliova; Peres,Mario Fernando Prieto; Porto Júnior,Pedro Paulo; Monzillo,Paulo Hélio; Okamoto,Ivan Hideyo; Massaro,Ayrton Roberto; Zirretta,José Carlos
Subject:carotid artery stent carotid artery atherosclerosis endovascular therapy
Year:2004
Country:Brazil
Document type:article
Access type:open access
Associated institution:IBICT
Language:English
Origin:Oasisbr
Description
Summary:We evaluate the results of stenting and angioplasty on carotid bifurcation stenotic lesions using protection systems, emphasizing the indications and technical aspects. Seventy-nine patients, mean age 64.5 years were treated from February,1998 to March, 2003. All patients were included in NASCET study criteria. Forty three patients were treated without the protection systems and thirty six were treated with carotid protection filtering system (Angioguard, EPI). Technical success and 6-months carotid Doppler ultrasound follow-up showing stent patency were achieved in all patients. One major stroke and one death due to intracranial reperfusion bleeding occurred in patients treated without cerebral protection devices. Only one patient presenting hyper perfusion syndrome improving after 7 days, was found in the group treated with the cerebral protection filter mechanism, no other neurologic symptom or death occured in this group. Stenting and angioplasty with protection systems for thromboembolic debris is a safe endovascular method to treat stenotic lesions in the carotid bifurcation with low morbidity and mortality.

Funded activities

No funded projects found.