Publicação
Determination of copper, iron, lead and zinc in gasoline by sequential multi-element flame atomic absorption spectrometry after solid phase extraction
| Resumo: | A procedure was developed for determination of copper, iron, lead and zinc in gasoline. The procedure was based on the preconcentration of metals using a resin modified with 3,4-dihydroxybenzoic acid (XAD-DHB), followed by desorption with an acid eluent. The components in the eluate were then determined by fast sequence flame atomic absorption spectrometry (FS-FAAS). The gasoline samples were prepared as microemulsions by mixing 80 mL of sample with 17 mL of propan-1-ol and 3 mL of a buffer solution (pH 10). The chemical and physical variables influencing the extraction were optimized. The LODs obtained were 2.2 µg L-1 Fe, 3.1 µg L-1 Cu, 2.3 µg L-1 Pb and 2.6 µg L-1 Zn. The RSDs ranged from 5.8 to 9.7% in samples spiked with 0.05 and 0.1 mg L-1 of each metal and recoveries varied from 82 to 99%. The procedure was suitable for determination of the analytes at µg L-1 levels in gasoline samples collected from several gas stations in Salvador, State of Bahia, Brazil. |
|---|---|
| Autores principais: | Santos,Denilson S. S |
| Outros Autores: | Korn,Maria Graças A; Guida,Mauro A. B; Santos,Gabriel L. dos; Lemos,Valfredo A; Teixeira,Leonardo S. G |
| Assunto: | preconcentration metal gasoline solid phase extraction FS-FAAS |
| Ano: | 2011 |
| País: | Brasil |
| Tipo de documento: | artigo |
| Tipo de acesso: | acesso aberto |
| Instituição associada: | IBICT |
| Idioma: | inglês |
| Origem: | Oasisbr |
| Resumo: | A procedure was developed for determination of copper, iron, lead and zinc in gasoline. The procedure was based on the preconcentration of metals using a resin modified with 3,4-dihydroxybenzoic acid (XAD-DHB), followed by desorption with an acid eluent. The components in the eluate were then determined by fast sequence flame atomic absorption spectrometry (FS-FAAS). The gasoline samples were prepared as microemulsions by mixing 80 mL of sample with 17 mL of propan-1-ol and 3 mL of a buffer solution (pH 10). The chemical and physical variables influencing the extraction were optimized. The LODs obtained were 2.2 µg L-1 Fe, 3.1 µg L-1 Cu, 2.3 µg L-1 Pb and 2.6 µg L-1 Zn. The RSDs ranged from 5.8 to 9.7% in samples spiked with 0.05 and 0.1 mg L-1 of each metal and recoveries varied from 82 to 99%. The procedure was suitable for determination of the analytes at µg L-1 levels in gasoline samples collected from several gas stations in Salvador, State of Bahia, Brazil. |
|---|
Atividades financiadas
Não foram encontrados projetos financiados.