Publicação

Real-time measurement of refractive index using 3D-printed optofluidic fiber sensor

Ver documento

Detalhes bibliográficos
Resumo:<jats:p>This work describes a 3D-printed optofluidic fiber sensor to measure refractive index in real time, combining a microfluidic system with an optical fiber extrinsic Fabry–Perot interferometer. The microfluidic chip platform was developed for this purpose through 3D printing. The Fabry–Perot cavity was incorporated in the microfluidic chip perpendicularly to the sample flow, which was of approximately 3.7 µL/s. The optofluidic fiber sensor platform coupled with a low-cost optical power meter detector was characterized using different concentrations of glucose solutions. In the linear regression analysis, the optical power shift was correlated with the refractive index and a sensitivity of −86.6 dB/RIU (r2 = 0.996) was obtained. Good results were obtained in terms of stability with a maximum standard deviation of 0.03 dB and a sensor resolution of 5.2 × 10−4 RIU. The feasibility of the optofluidic fiber sensor for dynamic analyses of refractive index with low sample usage was confirmed through real-time measurements.</jats:p>
Autores principais:Leça, João M.
Outros Autores:Magalhães, Yannis; Antunes, Paulo; Pereira, Vanda; Ferreira, Marta S.; Leça, João Micael
Assunto:Optofluidics Fabry–Perot Refractive index Real-time measurement . Faculdade de Ciências Exatas e da Engenharia
Ano:2022
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:Universidade da Madeira
Idioma:inglês
Origem:DigitUMa - Repositório da Universidade da Madeira
Descrição
Resumo:<jats:p>This work describes a 3D-printed optofluidic fiber sensor to measure refractive index in real time, combining a microfluidic system with an optical fiber extrinsic Fabry–Perot interferometer. The microfluidic chip platform was developed for this purpose through 3D printing. The Fabry–Perot cavity was incorporated in the microfluidic chip perpendicularly to the sample flow, which was of approximately 3.7 µL/s. The optofluidic fiber sensor platform coupled with a low-cost optical power meter detector was characterized using different concentrations of glucose solutions. In the linear regression analysis, the optical power shift was correlated with the refractive index and a sensitivity of −86.6 dB/RIU (r2 = 0.996) was obtained. Good results were obtained in terms of stability with a maximum standard deviation of 0.03 dB and a sensor resolution of 5.2 × 10−4 RIU. The feasibility of the optofluidic fiber sensor for dynamic analyses of refractive index with low sample usage was confirmed through real-time measurements.</jats:p>

Atividades financiadas

Carregando projetos financiados...