Publicação

Reliability of the handheld dynamometer in the evaluation of the muscle strength of trunk extensors in healthy adults

Ver documento

Detalhes bibliográficos
Resumo:ABSTRACT The muscular performance of the lumbar spine is frequently assessed in studies that compare populations with and without low back pain. However, the gold standard equipment used to evaluate the strength of these muscles has a high cost. Therefore, rarely used in the clinical practice of health professionals, being the handheld dynamometer an accessible alternative for use in clinical practice. Therefore, this study aimed to determine the reliability of the handheld dynamometer in the measurement of maximum voluntary isometric contraction of trunk extensors in healthy adults. Twenty-six healthy adults of both sexes (21.53± 1.88 years old) performed the test and retest with a 1-week interval. The comparison between test-retest demonstrated high and very high intraclass correlation coefficient for peak strength (0.82; 0.60 to 0.92) and mean strength (0.90; 0.76 to 0.95), respectively. Also, the Bland-Altman analyses indicate an error of 5.10 kg for peak strength and 5.7 kg for mean strength. In addition, the minimum detectable change for peak strength was 6.03kg (16.18%) and 5.92 kg for mean strength (20.95%). In conclusion, the test presents high reliability for the extensor muscles of the trunk in healthy adults. Therefore, the use of the handheld dynamometer can be indicated for clinical practice.
Autores principais:Barros,Mariana do Carmo Pinto Oliveira
Outros Autores:Clemente,Nathália Passos; Rezende,Fábio de Lima; Cardoso,Thaís Brasil; Thomaz,Sérgio Ricardo; Garcia,Patrícia Azevedo; Ribeiro,Alexandre Lima de Araújo; Martins,Wagner Rodrigues
Assunto:manual dynamometer assessment force back strength evidence-based practice
Ano:2021
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:Fundação para a Ciência e Tecnologia
Idioma:inglês
Origem:SciELO Portugal
_version_ 1877792189457629184
author Barros,Mariana do Carmo Pinto Oliveira
author2 Clemente,Nathália Passos
Rezende,Fábio de Lima
Cardoso,Thaís Brasil
Thomaz,Sérgio Ricardo
Garcia,Patrícia Azevedo
Ribeiro,Alexandre Lima de Araújo
Martins,Wagner Rodrigues
author2_role author
author
author
author
author
author
author
author_facet Barros,Mariana do Carmo Pinto Oliveira
Clemente,Nathália Passos
Rezende,Fábio de Lima
Cardoso,Thaís Brasil
Thomaz,Sérgio Ricardo
Garcia,Patrícia Azevedo
Ribeiro,Alexandre Lima de Araújo
Martins,Wagner Rodrigues
author_role author
country_str PT
creators_json_txt [{\"Person.name\":\"Barros,Mariana do Carmo Pinto Oliveira\"},{\"Person.name\":\"Clemente,Nathália Passos\"},{\"Person.name\":\"Rezende,Fábio de Lima\"},{\"Person.name\":\"Cardoso,Thaís Brasil\"},{\"Person.name\":\"Thomaz,Sérgio Ricardo\"},{\"Person.name\":\"Garcia,Patrícia Azevedo\"},{\"Person.name\":\"Ribeiro,Alexandre Lima de Araújo\"},{\"Person.name\":\"Martins,Wagner Rodrigues\"}]
datacite.creators.creator.creatorName.fl_str_mv Barros,Mariana do Carmo Pinto Oliveira
Clemente,Nathália Passos
Rezende,Fábio de Lima
Cardoso,Thaís Brasil
Thomaz,Sérgio Ricardo
Garcia,Patrícia Azevedo
Ribeiro,Alexandre Lima de Araújo
Martins,Wagner Rodrigues
datacite.rights.fl_str_mv http://purl.org/coar/access_right/c_abf2
datacite.subjects.subject.fl_str_mv manual dynamometer
assessment
force
back strength
evidence-based practice
datacite.titles.title.fl_str_mv Reliability of the handheld dynamometer in the evaluation of the muscle strength of trunk extensors in healthy adults
dc.creator.none.fl_str_mv Barros,Mariana do Carmo Pinto Oliveira
Clemente,Nathália Passos
Rezende,Fábio de Lima
Cardoso,Thaís Brasil
Thomaz,Sérgio Ricardo
Garcia,Patrícia Azevedo
Ribeiro,Alexandre Lima de Araújo
Martins,Wagner Rodrigues
dc.format.none.fl_str_mv text/html
dc.identifier.none.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2021000300235
dc.language.none.fl_str_mv eng
dc.publisher.none.fl_str_mv Edições Desafio Singular
dc.rights.none.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.source.none.fl_str_mv Motricidade v.17 n.3 2021
dc.subject.none.fl_str_mv manual dynamometer
assessment
force
back strength
evidence-based practice
dc.title.fl_str_mv Reliability of the handheld dynamometer in the evaluation of the muscle strength of trunk extensors in healthy adults
dc.type.none.fl_str_mv http://purl.org/coar/resource_type/c_6501
description ABSTRACT The muscular performance of the lumbar spine is frequently assessed in studies that compare populations with and without low back pain. However, the gold standard equipment used to evaluate the strength of these muscles has a high cost. Therefore, rarely used in the clinical practice of health professionals, being the handheld dynamometer an accessible alternative for use in clinical practice. Therefore, this study aimed to determine the reliability of the handheld dynamometer in the measurement of maximum voluntary isometric contraction of trunk extensors in healthy adults. Twenty-six healthy adults of both sexes (21.53± 1.88 years old) performed the test and retest with a 1-week interval. The comparison between test-retest demonstrated high and very high intraclass correlation coefficient for peak strength (0.82; 0.60 to 0.92) and mean strength (0.90; 0.76 to 0.95), respectively. Also, the Bland-Altman analyses indicate an error of 5.10 kg for peak strength and 5.7 kg for mean strength. In addition, the minimum detectable change for peak strength was 6.03kg (16.18%) and 5.92 kg for mean strength (20.95%). In conclusion, the test presents high reliability for the extensor muscles of the trunk in healthy adults. Therefore, the use of the handheld dynamometer can be indicated for clinical practice.
dirty 0
eu_rights_str_mv openAccess
format article
id scielopt_aa5cc85447d5dbd3bdb2c8b7a2f9c5bc
identifier.url.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2021000300235
inst_facet_str urn:organizationAcronym:scielo{{{_:::_}}}Fundação para a Ciência e Tecnologia
instacron_str SciELO
institution Fundação para a Ciência e Tecnologia
instname_str Fundação para a Ciência e Tecnologia
language eng
network_acronym_str scielopt
network_name_str SciELO Portugal
oai_identifier_str oai:scielo:S1646-107X2021000300235
organization_str_mv urn:organizationAcronym:scielo
person_str_mv Barros,Mariana do Carmo Pinto Oliveira
Clemente,Nathália Passos
Rezende,Fábio de Lima
Cardoso,Thaís Brasil
Thomaz,Sérgio Ricardo
Garcia,Patrícia Azevedo
Ribeiro,Alexandre Lima de Araújo
Martins,Wagner Rodrigues
publishDate 2021
publisher.none.fl_str_mv Edições Desafio Singular
repo_facet_str urn:repositoryAcronym:scielopt{{{_:::_}}}SciELO Portugal
reponame_str SciELO Portugal
repository_id_str urn:repositoryAcronym:scielopt
service_str_mv urn:repositoryAcronym:scielopt
spelling Reliability of the handheld dynamometer in the evaluation of the muscle strength of trunk extensors in healthy adultsBarros,Mariana do Carmo Pinto OliveiraClemente,Nathália PassosRezende,Fábio de LimaCardoso,Thaís BrasilThomaz,Sérgio RicardoGarcia,Patrícia AzevedoRibeiro,Alexandre Lima de AraújoMartins,Wagner Rodriguesmanual dynamometerassessmentforceback strengthevidence-based practiceopen accesshttp://purl.org/coar/access_right/c_abf2http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2021000300235URLhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2021000300235URLHasVersion2021-09-01ABSTRACT The muscular performance of the lumbar spine is frequently assessed in studies that compare populations with and without low back pain. However, the gold standard equipment used to evaluate the strength of these muscles has a high cost. Therefore, rarely used in the clinical practice of health professionals, being the handheld dynamometer an accessible alternative for use in clinical practice. Therefore, this study aimed to determine the reliability of the handheld dynamometer in the measurement of maximum voluntary isometric contraction of trunk extensors in healthy adults. Twenty-six healthy adults of both sexes (21.53± 1.88 years old) performed the test and retest with a 1-week interval. The comparison between test-retest demonstrated high and very high intraclass correlation coefficient for peak strength (0.82; 0.60 to 0.92) and mean strength (0.90; 0.76 to 0.95), respectively. Also, the Bland-Altman analyses indicate an error of 5.10 kg for peak strength and 5.7 kg for mean strength. In addition, the minimum detectable change for peak strength was 6.03kg (16.18%) and 5.92 kg for mean strength (20.95%). In conclusion, the test presents high reliability for the extensor muscles of the trunk in healthy adults. Therefore, the use of the handheld dynamometer can be indicated for clinical practice.Edições Desafio SingularMotricidade v.17 n.3 2021text/htmlengjournal articlehttp://purl.org/coar/resource_type/c_6501literature
spellingShingle Reliability of the handheld dynamometer in the evaluation of the muscle strength of trunk extensors in healthy adults
Barros,Mariana do Carmo Pinto Oliveira
manual dynamometer
assessment
force
back strength
evidence-based practice
status SINGLETON
subject.fl_str_mv manual dynamometer
assessment
force
back strength
evidence-based practice
title Reliability of the handheld dynamometer in the evaluation of the muscle strength of trunk extensors in healthy adults
title_full Reliability of the handheld dynamometer in the evaluation of the muscle strength of trunk extensors in healthy adults
title_fullStr Reliability of the handheld dynamometer in the evaluation of the muscle strength of trunk extensors in healthy adults
title_full_unstemmed Reliability of the handheld dynamometer in the evaluation of the muscle strength of trunk extensors in healthy adults
title_short Reliability of the handheld dynamometer in the evaluation of the muscle strength of trunk extensors in healthy adults
title_sort Reliability of the handheld dynamometer in the evaluation of the muscle strength of trunk extensors in healthy adults
topic manual dynamometer
assessment
force
back strength
evidence-based practice
topic_facet manual dynamometer
assessment
force
back strength
evidence-based practice
url http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2021000300235
visible 1

Atividades financiadas

Não foram encontrados projetos financiados.