Publicação
Comparative study of silicone-hydrogel contact lenses Surfaces before and after wear using atomic force microscopy
| Resumo: | Purpose: The aim of this study was to analyze surface changes of three silicone-hydrogel contact lenses after daily wear. The lenses used in this study were balafilcon A, lotrafilcon B (both surface-treated), and galyfilcon A (non surface-treated). Methods: To understand how and where proteins, lipids, and other contaminants change contact lenses, surface roughness was assessed through Atomic Force Microscopy Tapping ModeTM. Roughness parameters were Mean Surface roughness (Ra), Mean-square-roughness (Rq), and Maximum roughness (Rmax). The surface topography of unworn and worn lenses was also mapped in great detail. Results: Contact lenses roughness parameters exhibited different values before and after wear and the surface appearance also changed. After wear, balafilcon A and galyfilcon A showed a significant increase on surface roughness parameters, being this increase more accentuated to galyfilcon A. In lotrafilcon B materials no significant changes were observed with wear. Conclusions: The present study suggests that surface treatment of silicone-hydrogel contact lenses can play a role in the prevention of a significant increase in roughness, and contribute to the better clinical tolerance of these lenses. |
|---|---|
| Autores principais: | Lira, Madalena |
| Outros Autores: | Santos, Lívia; Azeredo, Joana; Yebra-Pimentel Vilar, Eva; Oliveira, M. Elisabete |
| Assunto: | Atomic force microscopy Contact lens Degradation Polymer Surface analysis |
| Ano: | 2008 |
| País: | Portugal |
| Tipo de documento: | artigo |
| Tipo de acesso: | acesso aberto |
| Instituição associada: | Universidade do Minho |
| Idioma: | inglês |
| Origem: | RepositóriUM - Universidade do Minho |
Registos relacionados
article Surface AFM microscopy of unworn and worn samples of silicone hydrogel contact lenses
por: González-Méijome, José Manuel
Publicado em: (2009)
por: González-Méijome, José Manuel
Publicado em: (2009)
category Influence of wear on bacterial adhesion and disinfection to silicone hydrogel contact lenses
por: Santos, Lívia
Publicado em: (2007)
por: Santos, Lívia
Publicado em: (2007)
category Surface charaterization of soft contact lenses by atomic force microscopy
por: Lira, Madalena
Publicado em: (2011)
por: Lira, Madalena
Publicado em: (2011)
article Soft contact lens surface profile by atomic force microscopy
por: Giraldez, Maria J.
Publicado em: (2010)
por: Giraldez, Maria J.
Publicado em: (2010)
article Silicone hydrogel contact lens surface analysis by atomic force microscopy: shape parameters
por: Giraldez, M. J.
Publicado em: (2011)
por: Giraldez, M. J.
Publicado em: (2011)
category The effect of conventional and silicone hydrogel contact lenses wear on the tear film
por: Lira, Madalena
Publicado em: (2006)
por: Lira, Madalena
Publicado em: (2006)
article Microscopic observation of unworn siloxane-hydrogel soft contact lenses by atomic force microscopy
por: González-Méijome, José Manuel
Publicado em: (2006)
por: González-Méijome, José Manuel
Publicado em: (2006)
article The effect of lens wear on refractive index of conventional hydrogel and silicone-hydrogel contact lenses: a comparative study
por: Lira, Madalena
Publicado em: (2008)
por: Lira, Madalena
Publicado em: (2008)
category Comparative study of silicone-hydrogel contact lenses surfaces before and after wear using atomic force microscopy
por: Lira, Madalena
Publicado em: (2007)
por: Lira, Madalena
Publicado em: (2007)
article Microscopic observations of superficial ultrastructure of unworn siloxane-hydrogel contact lenses by cryo-scanning electron microscopy
por: González-Méijome, José Manuel
Publicado em: (2006)
por: González-Méijome, José Manuel
Publicado em: (2006)
article Clinical performance and “ex vivo” dehydration of silicone hydrogel contact lenses with two new multipurpose solutions
por: González-Méijome, José Manuel
Publicado em: (2013)
por: González-Méijome, José Manuel
Publicado em: (2013)
article Oxygen transmissibility of piggyback systems with conventional soft and silicone hydrogel contact lenses
por: López-Alemany, António
Publicado em: (2006)
por: López-Alemany, António
Publicado em: (2006)
article Influence of environmental factors in the in vitro dehydration of hydrogel and silicone hydrogel contact lenses
por: Martín-Montañez, Vicente
Publicado em: (2014)
por: Martín-Montañez, Vicente
Publicado em: (2014)
article Effect of lens care systems on silicone hydrogel contact lens hydrophobicity
por: Lira, Madalena
Publicado em: (2017)
por: Lira, Madalena
Publicado em: (2017)
category Changes in UVR-Visible transmittance induced by wear on silicone-hydrogel contact lenses
por: Lira, Madalena
Publicado em: (2008)
por: Lira, Madalena
Publicado em: (2008)
image Influence of contact lens care solutions on the water content of hydrogel and silicone-hydrogel contact lenses
por: Machado, Ana Rita Silva
Publicado em: (2015)
por: Machado, Ana Rita Silva
Publicado em: (2015)
article Changes in UV-visible transmittance of silicone-hydrogel contact lenses induced by wear
por: Lira, Madalena
Publicado em: (2009)
por: Lira, Madalena
Publicado em: (2009)
book Atomic Force Microscopy: A Powerful Tool for Electrical Characterization
por: Tararam, Ronald
Publicado em: (2022)
por: Tararam, Ronald
Publicado em: (2022)
book Silicone hydrogel materials for contact lens applications
por: González-Méijome, José Manuel
Publicado em: (2014)
por: González-Méijome, José Manuel
Publicado em: (2014)
article Atomic Force Microscopy of spermidine-induced DNA condensates on silicon surfaces
por: Carrasco, I.S.S.
Publicado em: (2018)
por: Carrasco, I.S.S.
Publicado em: (2018)
article Quality of vision with spectacles, special silicone hydrogel and gas permeable contact lenses in keratoconic patients
por: González-Méijome, José Manuel
Publicado em: (2013)
por: González-Méijome, José Manuel
Publicado em: (2013)
category Layer-by-layer coated silicone-based soft contact lens hydrogel for diclofenac sustained release
por: Silva, Diana
Publicado em: (2021)
por: Silva, Diana
Publicado em: (2021)
article Contact lens hydrophobicity and roughness effects on bacterial adhesion
por: Giraldez, Maria J.
Publicado em: (2010)
por: Giraldez, Maria J.
Publicado em: (2010)
book Silicone hydrogels materials for contact lens applications
por: González-Méijome, José Manuel
Publicado em: (2014)
por: González-Méijome, José Manuel
Publicado em: (2014)
article Qualitative and quantitative characterization of the in vitro dehydration process of hydrogel contact lenses
por: González-Méijome, José Manuel
Publicado em: (2007)
por: González-Méijome, José Manuel
Publicado em: (2007)
article Controlled drug release from hydrogels for contact lenses: drug partitioning and diffusion
por: Pimenta, A.F.R.
Publicado em: (2016)
por: Pimenta, A.F.R.
Publicado em: (2016)
article Atomic force microscopy characterization of an electrochemical DNA-biosensor
por: Paquim, Ana Maria Chiorcea
Publicado em: (2004)
por: Paquim, Ana Maria Chiorcea
Publicado em: (2004)
article Corneal epithelial thinning profile induced by long-term wear of hydrogel lenses
por: González-Pérez, Javier
Publicado em: (2003)
por: González-Pérez, Javier
Publicado em: (2003)
article Effect of sport-tinted contact lenses for contrast enhancement on retinal straylight measurements
por: Cerviño, Alejandro
Publicado em: (2008)
por: Cerviño, Alejandro
Publicado em: (2008)
article Refractive index and equilibrium water content of conventional and silicone hydrogel contact lenses
por: González-Méijome, José Manuel
Publicado em: (2006)
por: González-Méijome, José Manuel
Publicado em: (2006)
article Keratoconus and Visual Performance with Different Contact Lenses
por: Marta, Ana
Publicado em: (2021)
por: Marta, Ana
Publicado em: (2021)
groups Ocular drug delivery from contact lenses: mimetizing the hydrodynamic conditions of the eye
por: Pimenta, Andreia
Publicado em: (2016)
por: Pimenta, Andreia
Publicado em: (2016)
article Determination of central corneal clearance in scleral lenses with an optical biometer and agreement with subjective evaluation
por: Macedo-de-Araujo, Rute J.
Publicado em: (2019)
por: Macedo-de-Araujo, Rute J.
Publicado em: (2019)
article An Atomic Force Microscopy Study of the Interactions Involving Polymers and Silane Networks
por: Oréfice,Rodrigo L.
Publicado em: (1998)
por: Oréfice,Rodrigo L.
Publicado em: (1998)
image Evaluation of cytotoxic potential and inflammatory response of different types of contact lenses before wear
por: Lira, Madalena
Publicado em: (2017)
por: Lira, Madalena
Publicado em: (2017)
article Effect of environmental conditions on the concentration of tear inflammatory mediators during contact lens wear
por: Martín-Montañez, Vicente
Publicado em: (2016)
por: Martín-Montañez, Vicente
Publicado em: (2016)
article Taking nanomedicine teaching into practice with atomic force microscopy and force spectroscopy
por: Carvalho, Filomena A.
Publicado em: (2015)
por: Carvalho, Filomena A.
Publicado em: (2015)
article Soft contact lenses for keratoconus: case report
por: González-Méijome, José Manuel
Publicado em: (2006)
por: González-Méijome, José Manuel
Publicado em: (2006)
article Non-contact specular microscopy in aphakic and pseudophakic dogs
por: Nagatsuyu,Claudia Emi
Publicado em: (2014)
por: Nagatsuyu,Claudia Emi
Publicado em: (2014)
article Atomic force microscopy-based force spectroscopy - biological and biomedical applications
por: Carvalho, Filomena A.
Publicado em: (2012)
por: Carvalho, Filomena A.
Publicado em: (2012)
Atividades financiadas
Não foram encontrados projetos financiados.
Registos relacionados
-
article Surface AFM microscopy of unworn and worn samples of silicone hydrogel contact lenses
por: González-Méijome, José Manuel
Publicado em: (2009) -
category Influence of wear on bacterial adhesion and disinfection to silicone hydrogel contact lenses
por: Santos, Lívia
Publicado em: (2007) -
category Surface charaterization of soft contact lenses by atomic force microscopy
por: Lira, Madalena
Publicado em: (2011) -
article Soft contact lens surface profile by atomic force microscopy
por: Giraldez, Maria J.
Publicado em: (2010) -
article Silicone hydrogel contact lens surface analysis by atomic force microscopy: shape parameters
por: Giraldez, M. J.
Publicado em: (2011)