Publicação

Automatic prebent customized prosthesis for pectus excavatum minimally invasive surgery correction

Ver documento

Detalhes bibliográficos
Resumo:Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients' sides. It highlighted that the prosthesis bar should be modeled according to each patient's rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
Autores principais:Vilaça, João L.
Outros Autores:Rodrigues, Pedro L.; Soares, Tony Ramos; Fonseca, Jaime C.; Pinho, António C. M.; Coelho, Tiago Henriques; Correia-Pinto, Jorge
Assunto:Adolescent Adult Child Cohort Studies Funnel Chest Humans Male Minimally Invasive Surgical Procedures Prostheses and Implants Prosthesis Design Prosthesis Implantation Radiography, Thoracic Surveys and Questionnaires Young Adult Pectus excavatum Biomedical engineering Pediatric surgery Personalized prosthesis
Ano:2014
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso restrito
Instituição associada:Universidade do Minho
Idioma:inglês
Origem:RepositóriUM - Universidade do Minho
_version_ 1877774969719488512
author Vilaça, João L.
author2 Rodrigues, Pedro L.
Soares, Tony Ramos
Fonseca, Jaime C.
Pinho, António C. M.
Coelho, Tiago Henriques
Correia-Pinto, Jorge
author2_role author
author
author
author
author
author
author_facet Vilaça, João L.
Rodrigues, Pedro L.
Soares, Tony Ramos
Fonseca, Jaime C.
Pinho, António C. M.
Coelho, Tiago Henriques
Correia-Pinto, Jorge
author_role author
contributor_name_str_mv RepositóriUM - Universidade do Minho
country_str PT
creators_json_txt [{\"Person.name\":\"Vilaça, João L.\"},{\"Person.name\":\"Rodrigues, Pedro L.\"},{\"Person.name\":\"Soares, Tony Ramos\"},{\"Person.name\":\"Fonseca, Jaime C.\"},{\"Person.name\":\"Pinho, António C. M.\"},{\"Person.name\":\"Coelho, Tiago Henriques\"},{\"Person.name\":\"Correia-Pinto, Jorge\"}]
datacite.contributors.contributor.contributorName.fl_str_mv RepositóriUM - Universidade do Minho
datacite.creators.creator.creatorName.fl_str_mv Vilaça, João L.
Rodrigues, Pedro L.
Soares, Tony Ramos
Fonseca, Jaime C.
Pinho, António C. M.
Coelho, Tiago Henriques
Correia-Pinto, Jorge
datacite.date.Accepted.fl_str_mv 2014-06-01T00:00:00Z
datacite.date.embargoed.fl_str_mv 10000-01-01T00:00:00Z
datacite.rights.fl_str_mv http://purl.org/coar/access_right/c_16ec
datacite.subjects.subject.fl_str_mv Adolescent
Adult
Child
Cohort Studies
Funnel Chest
Humans
Male
Minimally Invasive Surgical Procedures
Prostheses and Implants
Prosthesis Design
Prosthesis Implantation
Radiography, Thoracic
Surveys and Questionnaires
Young Adult
Pectus excavatum
Biomedical engineering
Pediatric surgery
Personalized prosthesis
datacite.titles.title.fl_str_mv Automatic prebent customized prosthesis for pectus excavatum minimally invasive surgery correction
dc.contributor.none.fl_str_mv RepositóriUM - Universidade do Minho
dc.creator.none.fl_str_mv Vilaça, João L.
Rodrigues, Pedro L.
Soares, Tony Ramos
Fonseca, Jaime C.
Pinho, António C. M.
Coelho, Tiago Henriques
Correia-Pinto, Jorge
dc.date.Accepted.fl_str_mv 2014-06-01T00:00:00Z
dc.date.embargoed.fl_str_mv 10000-01-01T00:00:00Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv https://hdl.handle.net/1822/62111
dc.language.none.fl_str_mv eng
dc.publisher.none.fl_str_mv SAGE Publications
dc.rights.none.fl_str_mv http://purl.org/coar/access_right/c_16ec
dc.subject.none.fl_str_mv Adolescent
Adult
Child
Cohort Studies
Funnel Chest
Humans
Male
Minimally Invasive Surgical Procedures
Prostheses and Implants
Prosthesis Design
Prosthesis Implantation
Radiography, Thoracic
Surveys and Questionnaires
Young Adult
Pectus excavatum
Biomedical engineering
Pediatric surgery
Personalized prosthesis
dc.title.fl_str_mv Automatic prebent customized prosthesis for pectus excavatum minimally invasive surgery correction
dc.type.none.fl_str_mv http://purl.org/coar/resource_type/c_6501
description Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients' sides. It highlighted that the prosthesis bar should be modeled according to each patient's rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
dirty 0
eu_rights_str_mv restrictedAccess
format article
id rum_75bf56a417a87f7f772207bf4df48994
identifier.url.fl_str_mv https://hdl.handle.net/1822/62111
inst_facet_str urn:organizationAcronym:repositorium{{{_:::_}}}Universidade do Minho
instacron_str repositorium
institution Universidade do Minho
instname_str Universidade do Minho
language eng
network_acronym_str rum
network_name_str RepositóriUM - Universidade do Minho
oai_identifier_str oai:repositorium.uminho.pt:1822/62111
organization_str_mv urn:organizationAcronym:repositorium
person_str_mv Vilaça, João L.
Rodrigues, Pedro L.
Soares, Tony Ramos
Fonseca, Jaime C.
Pinho, António C. M.
Coelho, Tiago Henriques
Correia-Pinto, Jorge
publishDate 2014
publisher.none.fl_str_mv SAGE Publications
repo_facet_str urn:repositoryAcronym:rum{{{_:::_}}}RepositóriUM - Universidade do Minho
reponame_str RepositóriUM - Universidade do Minho
repository_id_str urn:repositoryAcronym:rum
service_str_mv urn:repositoryAcronym:rum
spelling engSAGE PublicationsporPectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients' sides. It highlighted that the prosthesis bar should be modeled according to each patient's rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.application/pdfporAutomatic prebent customized prosthesis for pectus excavatum minimally invasive surgery correctionVilaça, João L.Rodrigues, Pedro L.Soares, Tony RamosFonseca, Jaime C.Pinho, António C. M.Coelho, Tiago HenriquesCorreia-Pinto, JorgeHostingInstitutionOrganizationalRepositóriUM - Universidade do Minhoe-mailmailto:repositorium@usdb.uminho.ptrepositorium@usdb.uminho.ptPMID24151136ISSNIsPartOf1553-3506EISSNIsPartOf1553-3514DOIIsPartOf10.1177/15533506135062992014-062014-06-01T00:00:00Z10000-01-01T00:00:00ZHandlehttps://hdl.handle.net/1822/62111http://purl.org/coar/access_right/c_16ecrestricted accessAdolescentAdultChildCohort StudiesFunnel ChestHumansMaleMinimally Invasive Surgical ProceduresProstheses and ImplantsProsthesis DesignProsthesis ImplantationRadiography, ThoracicSurveys and QuestionnairesYoung AdultPectus excavatumBiomedical engineeringPediatric surgeryPersonalized prosthesis614616 bytesliteraturehttp://purl.org/coar/resource_type/c_6501journal articlehttp://purl.org/coar/access_right/c_f1cfapplication/pdfhttps://repositorium.uminho.pt/bitstreams/84938047-0c40-4b05-96a5-cd7b2a7d6639/download
spellingShingle Automatic prebent customized prosthesis for pectus excavatum minimally invasive surgery correction
Vilaça, João L.
Adolescent
Adult
Child
Cohort Studies
Funnel Chest
Humans
Male
Minimally Invasive Surgical Procedures
Prostheses and Implants
Prosthesis Design
Prosthesis Implantation
Radiography, Thoracic
Surveys and Questionnaires
Young Adult
Pectus excavatum
Biomedical engineering
Pediatric surgery
Personalized prosthesis
status SINGLETON
subject.fl_str_mv Adolescent
Adult
Child
Cohort Studies
Funnel Chest
Humans
Male
Minimally Invasive Surgical Procedures
Prostheses and Implants
Prosthesis Design
Prosthesis Implantation
Radiography, Thoracic
Surveys and Questionnaires
Young Adult
Pectus excavatum
Biomedical engineering
Pediatric surgery
Personalized prosthesis
title Automatic prebent customized prosthesis for pectus excavatum minimally invasive surgery correction
title_full Automatic prebent customized prosthesis for pectus excavatum minimally invasive surgery correction
title_fullStr Automatic prebent customized prosthesis for pectus excavatum minimally invasive surgery correction
title_full_unstemmed Automatic prebent customized prosthesis for pectus excavatum minimally invasive surgery correction
title_short Automatic prebent customized prosthesis for pectus excavatum minimally invasive surgery correction
title_sort Automatic prebent customized prosthesis for pectus excavatum minimally invasive surgery correction
topic Adolescent
Adult
Child
Cohort Studies
Funnel Chest
Humans
Male
Minimally Invasive Surgical Procedures
Prostheses and Implants
Prosthesis Design
Prosthesis Implantation
Radiography, Thoracic
Surveys and Questionnaires
Young Adult
Pectus excavatum
Biomedical engineering
Pediatric surgery
Personalized prosthesis
topic_facet Adolescent
Adult
Child
Cohort Studies
Funnel Chest
Humans
Male
Minimally Invasive Surgical Procedures
Prostheses and Implants
Prosthesis Design
Prosthesis Implantation
Radiography, Thoracic
Surveys and Questionnaires
Young Adult
Pectus excavatum
Biomedical engineering
Pediatric surgery
Personalized prosthesis
url https://hdl.handle.net/1822/62111
visible 1

Atividades financiadas

Não foram encontrados projetos financiados.