Publicação
Surface AFM microscopy of unworn and worn samples of silicone hydrogel contact lenses
| Resumo: | Abstract: Purpose. To evaluate the qualitative and quantitative topographic changes in the surface of worn contact lenses (CLs) of different materials using atomic force microscopy (AFM). Methods. The topography of five different CL materials was evaluated withAFM over a surface of 25 lm2 according to previously published experimental setup. Average roughness (Ra) and root mean square (Rms) values were obtained for unworn and worn samples. Results. The Ra value increased for balafilcon A (11.62–13.68 nm for unworn and worn samples, respectively), lotrafilcon A (3.67–15.01 nm for unworn and worn samples, respectively), lotrafilcon B (4.08–8.42 nm for unworn and worn samples, respectively), galyfilcon A (2.81–14.6 nm for unworn and worn samples, respectively), and comfilcon A (2.87–4.63 nm for unworn and worn samples, respectively). Differences were statistically significant for all lenses except Rms and Ra for comfilcon A, and Ra parameter for balafilcon A (p > 0.05). The least relative increase was observed for some balafilcon A samples and for some of these samples the roughness decreased after the lenses had been worn. Conclusion. The changes in surface roughness between unworn and worn lenses are different for different silicone-hydrogel materials. Overall all CLs increased the degree of surface roughness after being worn, even for very short periods of time. However, for samples of balafilcon A, roughness increases at a lower extent or even can decrease as compared to unworn samples of the same material due to filling of the macropores. |
|---|---|
| Autores principais: | González-Méijome, José Manuel |
| Outros Autores: | López-Alemany, António; Almeida, José B.; Parafita, Manuel A. |
| Assunto: | Atomic force microscopy Contact lens Polymer deterioration Surface characterization degradation wear |
| Ano: | 2009 |
| País: | Portugal |
| Tipo de documento: | artigo |
| Tipo de acesso: | acesso aberto |
| Instituição associada: | Universidade do Minho |
| Idioma: | inglês |
| Origem: | RepositóriUM - Universidade do Minho |
Registos relacionados
article Comparative study of silicone-hydrogel contact lenses Surfaces before and after wear using atomic force microscopy
por: Lira, Madalena
Publicado em: (2008)
por: Lira, Madalena
Publicado em: (2008)
article Microscopic observation of unworn siloxane-hydrogel soft contact lenses by atomic force microscopy
por: González-Méijome, José Manuel
Publicado em: (2006)
por: González-Méijome, José Manuel
Publicado em: (2006)
article Microscopic observations of superficial ultrastructure of unworn siloxane-hydrogel contact lenses by cryo-scanning electron microscopy
por: González-Méijome, José Manuel
Publicado em: (2006)
por: González-Méijome, José Manuel
Publicado em: (2006)
book Analysis of surface mechanical properties of unworn and worn silicone hydrogel contact lenses using nanoindentation with AFM
por: González-Méijome, José Manuel
Publicado em: (2010)
por: González-Méijome, José Manuel
Publicado em: (2010)
category Influence of wear on bacterial adhesion and disinfection to silicone hydrogel contact lenses
por: Santos, Lívia
Publicado em: (2007)
por: Santos, Lívia
Publicado em: (2007)
article Clinical performance and “ex vivo” dehydration of silicone hydrogel contact lenses with two new multipurpose solutions
por: González-Méijome, José Manuel
Publicado em: (2013)
por: González-Méijome, José Manuel
Publicado em: (2013)
article Silicone hydrogel contact lens surface analysis by atomic force microscopy: shape parameters
por: Giraldez, M. J.
Publicado em: (2011)
por: Giraldez, M. J.
Publicado em: (2011)
article Soft contact lens surface profile by atomic force microscopy
por: Giraldez, Maria J.
Publicado em: (2010)
por: Giraldez, Maria J.
Publicado em: (2010)
category The effect of conventional and silicone hydrogel contact lenses wear on the tear film
por: Lira, Madalena
Publicado em: (2006)
por: Lira, Madalena
Publicado em: (2006)
book Silicone hydrogel materials for contact lens applications
por: González-Méijome, José Manuel
Publicado em: (2014)
por: González-Méijome, José Manuel
Publicado em: (2014)
category Attachment of a clinical strain of Staphylococcus epidermidis to worn and unworn silicone hydrogel contact lenses
por: Santos, Lívia
Publicado em: (2006)
por: Santos, Lívia
Publicado em: (2006)
article Oxygen transmissibility of piggyback systems with conventional soft and silicone hydrogel contact lenses
por: López-Alemany, António
Publicado em: (2006)
por: López-Alemany, António
Publicado em: (2006)
article Quality of vision with spectacles, special silicone hydrogel and gas permeable contact lenses in keratoconic patients
por: González-Méijome, José Manuel
Publicado em: (2013)
por: González-Méijome, José Manuel
Publicado em: (2013)
category Surface charaterization of soft contact lenses by atomic force microscopy
por: Lira, Madalena
Publicado em: (2011)
por: Lira, Madalena
Publicado em: (2011)
article Influence of environmental factors in the in vitro dehydration of hydrogel and silicone hydrogel contact lenses
por: Martín-Montañez, Vicente
Publicado em: (2014)
por: Martín-Montañez, Vicente
Publicado em: (2014)
book Silicone hydrogels materials for contact lens applications
por: González-Méijome, José Manuel
Publicado em: (2014)
por: González-Méijome, José Manuel
Publicado em: (2014)
article Qualitative and quantitative characterization of the in vitro dehydration process of hydrogel contact lenses
por: González-Méijome, José Manuel
Publicado em: (2007)
por: González-Méijome, José Manuel
Publicado em: (2007)
image Influence of contact lens care solutions on the water content of hydrogel and silicone-hydrogel contact lenses
por: Machado, Ana Rita Silva
Publicado em: (2015)
por: Machado, Ana Rita Silva
Publicado em: (2015)
article Refractive index and equilibrium water content of conventional and silicone hydrogel contact lenses
por: González-Méijome, José Manuel
Publicado em: (2006)
por: González-Méijome, José Manuel
Publicado em: (2006)
article Effect of lens care systems on silicone hydrogel contact lens hydrophobicity
por: Lira, Madalena
Publicado em: (2017)
por: Lira, Madalena
Publicado em: (2017)
category Layer-by-layer coated silicone-based soft contact lens hydrogel for diclofenac sustained release
por: Silva, Diana
Publicado em: (2021)
por: Silva, Diana
Publicado em: (2021)
article Corneal epithelial thinning profile induced by long-term wear of hydrogel lenses
por: González-Pérez, Javier
Publicado em: (2003)
por: González-Pérez, Javier
Publicado em: (2003)
article The effect of lens wear on refractive index of conventional hydrogel and silicone-hydrogel contact lenses: a comparative study
por: Lira, Madalena
Publicado em: (2008)
por: Lira, Madalena
Publicado em: (2008)
article Soft contact lenses for keratoconus: case report
por: González-Méijome, José Manuel
Publicado em: (2006)
por: González-Méijome, José Manuel
Publicado em: (2006)
article Contact lens hydrophobicity and roughness effects on bacterial adhesion
por: Giraldez, Maria J.
Publicado em: (2010)
por: Giraldez, Maria J.
Publicado em: (2010)
article Bacterial adhesion to worn silicone hydrogel contact lenses
por: Santos, Lívia
Publicado em: (2008)
por: Santos, Lívia
Publicado em: (2008)
article Controlled drug release from hydrogels for contact lenses: drug partitioning and diffusion
por: Pimenta, A.F.R.
Publicado em: (2016)
por: Pimenta, A.F.R.
Publicado em: (2016)
article Effect of sport-tinted contact lenses for contrast enhancement on retinal straylight measurements
por: Cerviño, Alejandro
Publicado em: (2008)
por: Cerviño, Alejandro
Publicado em: (2008)
article Keratoconus and Visual Performance with Different Contact Lenses
por: Marta, Ana
Publicado em: (2021)
por: Marta, Ana
Publicado em: (2021)
article Strategies to regulate myopia progression with contact lenses: a review
por: González-Méijome, José Manuel
Publicado em: (2016)
por: González-Méijome, José Manuel
Publicado em: (2016)
groups Ocular drug delivery from contact lenses: mimetizing the hydrodynamic conditions of the eye
por: Pimenta, Andreia
Publicado em: (2016)
por: Pimenta, Andreia
Publicado em: (2016)
article Determination of oxygen permeability in soft contact lenses using a polarographic method : estimation of relevant physiological parameters
por: González-Méijome, José Manuel
Publicado em: (2008)
por: González-Méijome, José Manuel
Publicado em: (2008)
category Efficacy of worn silicone hydrogel contact lenses desinfectation by a multipurpose solution
por: Santos, Lívia
Publicado em: (2006)
por: Santos, Lívia
Publicado em: (2006)
article Determination of central corneal clearance in scleral lenses with an optical biometer and agreement with subjective evaluation
por: Macedo-de-Araujo, Rute J.
Publicado em: (2019)
por: Macedo-de-Araujo, Rute J.
Publicado em: (2019)
article Non-contact specular microscopy in aphakic and pseudophakic dogs
por: Nagatsuyu,Claudia Emi
Publicado em: (2014)
por: Nagatsuyu,Claudia Emi
Publicado em: (2014)
article Peripheral refraction with eye and head rotation with contact lenses
por: Ferreira, Daniela Patrícia Lopes
Publicado em: (2015)
por: Ferreira, Daniela Patrícia Lopes
Publicado em: (2015)
article Effects of two different contact lenses on ocular physiological parameters and tear function tests
por: Ugurlu,Adem
Publicado em: (2019)
por: Ugurlu,Adem
Publicado em: (2019)
category Changes in UVR-Visible transmittance induced by wear on silicone-hydrogel contact lenses
por: Lira, Madalena
Publicado em: (2008)
por: Lira, Madalena
Publicado em: (2008)
article Emerging Trends in Nanomedicine for Improving Ocular Drug Delivery: Light-Responsive Nanoparticles, Mesoporous Silica Nanoparticles, and Contact Lenses
por: Rodrigues, Flávia S. C.
Publicado em: (2020)
por: Rodrigues, Flávia S. C.
Publicado em: (2020)
groups Diclofenac release from a silicon based contact lens material controlled by a chitosan/alginate coating
por: Filipe, Helena
Publicado em: (2016)
por: Filipe, Helena
Publicado em: (2016)
Atividades financiadas
Não foram encontrados projetos financiados.
Registos relacionados
-
article Comparative study of silicone-hydrogel contact lenses Surfaces before and after wear using atomic force microscopy
por: Lira, Madalena
Publicado em: (2008) -
article Microscopic observation of unworn siloxane-hydrogel soft contact lenses by atomic force microscopy
por: González-Méijome, José Manuel
Publicado em: (2006) -
article Microscopic observations of superficial ultrastructure of unworn siloxane-hydrogel contact lenses by cryo-scanning electron microscopy
por: González-Méijome, José Manuel
Publicado em: (2006) -
book Analysis of surface mechanical properties of unworn and worn silicone hydrogel contact lenses using nanoindentation with AFM
por: González-Méijome, José Manuel
Publicado em: (2010) -
category Influence of wear on bacterial adhesion and disinfection to silicone hydrogel contact lenses
por: Santos, Lívia
Publicado em: (2007)