Publicação

Morphology dependence degradation of electro- and magnetoactive poly(3-hydroxybutyrate-co-hydroxyvalerate) for tissue engineering applications

Ver documento

Detalhes bibliográficos
Resumo:Poly(hydroxybutyrate-co-hydroxyvalerate) (PHBV) is a piezoelectric biodegradable and biocompatible polymer suitable for tissue engineering applications. The incorporation of magnetostrictive cobalt ferrites (CFO) into PHBV matrix enables the production of magnetically responsive composites, which proved to be effective in the differentiation of a variety of cells and tissues. In this work, PHBV and PHBV with CFO nanoparticles were produced in the form of films, fibers and porous scaffolds and subjected to an experimental program allowing to evaluate the degradation process under biological conditions for a period up to 8 weeks. The morphology, physical, chemical and thermal properties were evaluated, together with the weight loss of the samples during the in vitro degradation assays. No major changes in the mentioned properties were found, thus proving its applicability for tissue engineering applications. Degradation was apparent from week 4 and onwards, leading to the conclusion that the degradation ratio of the material is suitable for a large range of tissue engineering applications. Further, it was found that the degradation of the samples maintain the biocompatibility of the materials for the pristine polymer, but can lead to cytotoxic effects when the magnetic CFO nanoparticles are exposed, being therefore needed, for magnetoactive applications, to substitute them by biocompatible ferrites, such as an iron oxide (Fe3O4).
Autores principais:Amaro, Luis
Outros Autores:Correia, Daniela M.; Martins, Pedro Manuel Abreu; Botelho, Gabriela; Carabineiro, Sónia A. C.; Ribeiro, Clarisse Marta Oliveira; Lanceros-Méndez, S.
Assunto:piezoelectric materials poly(hydroxybutyrate-co-hydroxyvalerate) hydrolytic degradation tissue engineering
Ano:2020
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:Universidade do Minho
Idioma:inglês
Origem:RepositóriUM - Universidade do Minho
_version_ 1877774791768801280
author Amaro, Luis
author2 Correia, Daniela M.
Martins, Pedro Manuel Abreu
Botelho, Gabriela
Carabineiro, Sónia A. C.
Ribeiro, Clarisse Marta Oliveira
Lanceros-Méndez, S.
author2_role author
author
author
author
author
author
author_facet Amaro, Luis
Correia, Daniela M.
Martins, Pedro Manuel Abreu
Botelho, Gabriela
Carabineiro, Sónia A. C.
Ribeiro, Clarisse Marta Oliveira
Lanceros-Méndez, S.
author_role author
contributor_name_str_mv RepositóriUM - Universidade do Minho
country_str PT
creators_json_txt [{\"Person.name\":\"Amaro, Luis\"},{\"Person.name\":\"Correia, Daniela M.\"},{\"Person.name\":\"Martins, Pedro Manuel Abreu\"},{\"Person.name\":\"Botelho, Gabriela\"},{\"Person.name\":\"Carabineiro, Sónia A. C.\"},{\"Person.name\":\"Ribeiro, Clarisse Marta Oliveira\"},{\"Person.name\":\"Lanceros-Méndez, S.\"}]
datacite.contributors.contributor.contributorName.fl_str_mv RepositóriUM - Universidade do Minho
datacite.creators.creator.creatorName.fl_str_mv Amaro, Luis
Correia, Daniela M.
Martins, Pedro Manuel Abreu
Botelho, Gabriela
Carabineiro, Sónia A. C.
Ribeiro, Clarisse Marta Oliveira
Lanceros-Méndez, S.
datacite.date.Accepted.fl_str_mv 2020-04-16T00:00:00Z
datacite.rights.fl_str_mv http://purl.org/coar/access_right/c_abf2
datacite.subjects.subject.fl_str_mv piezoelectric materials
poly(hydroxybutyrate-co-hydroxyvalerate)
hydrolytic degradation
tissue engineering
datacite.titles.title.fl_str_mv Morphology dependence degradation of electro- and magnetoactive poly(3-hydroxybutyrate-co-hydroxyvalerate) for tissue engineering applications
dc.contributor.none.fl_str_mv RepositóriUM - Universidade do Minho
dc.creator.none.fl_str_mv Amaro, Luis
Correia, Daniela M.
Martins, Pedro Manuel Abreu
Botelho, Gabriela
Carabineiro, Sónia A. C.
Ribeiro, Clarisse Marta Oliveira
Lanceros-Méndez, S.
dc.date.Accepted.fl_str_mv 2020-04-16T00:00:00Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv https://hdl.handle.net/1822/65104
dc.language.none.fl_str_mv eng
dc.publisher.none.fl_str_mv MDPI
dc.rights.cclincense.fl_str_mv http://creativecommons.org/licenses/by/4.0/
dc.rights.none.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.rights.copyright.fl_str_mv openAccess
dc.subject.none.fl_str_mv piezoelectric materials
poly(hydroxybutyrate-co-hydroxyvalerate)
hydrolytic degradation
tissue engineering
dc.title.fl_str_mv Morphology dependence degradation of electro- and magnetoactive poly(3-hydroxybutyrate-co-hydroxyvalerate) for tissue engineering applications
dc.type.none.fl_str_mv http://purl.org/coar/resource_type/c_6501
description Poly(hydroxybutyrate-co-hydroxyvalerate) (PHBV) is a piezoelectric biodegradable and biocompatible polymer suitable for tissue engineering applications. The incorporation of magnetostrictive cobalt ferrites (CFO) into PHBV matrix enables the production of magnetically responsive composites, which proved to be effective in the differentiation of a variety of cells and tissues. In this work, PHBV and PHBV with CFO nanoparticles were produced in the form of films, fibers and porous scaffolds and subjected to an experimental program allowing to evaluate the degradation process under biological conditions for a period up to 8 weeks. The morphology, physical, chemical and thermal properties were evaluated, together with the weight loss of the samples during the in vitro degradation assays. No major changes in the mentioned properties were found, thus proving its applicability for tissue engineering applications. Degradation was apparent from week 4 and onwards, leading to the conclusion that the degradation ratio of the material is suitable for a large range of tissue engineering applications. Further, it was found that the degradation of the samples maintain the biocompatibility of the materials for the pristine polymer, but can lead to cytotoxic effects when the magnetic CFO nanoparticles are exposed, being therefore needed, for magnetoactive applications, to substitute them by biocompatible ferrites, such as an iron oxide (Fe3O4).
dirty 0
eu_rights_str_mv openAccess
format article
id rum_15ae18f7b5f889bd003d86cbb2645f7c
identifier.url.fl_str_mv https://hdl.handle.net/1822/65104
inst_facet_str urn:organizationAcronym:repositorium{{{_:::_}}}Universidade do Minho
instacron_str repositorium
institution Universidade do Minho
instname_str Universidade do Minho
language eng
network_acronym_str rum
network_name_str RepositóriUM - Universidade do Minho
oai_identifier_str oai:repositorium.uminho.pt:1822/65104
organization_str_mv urn:organizationAcronym:repositorium
person_str_mv Amaro, Luis
Correia, Daniela M.
Martins, Pedro Manuel Abreu
Botelho, Gabriela
Carabineiro, Sónia A. C.
Ribeiro, Clarisse Marta Oliveira
Lanceros-Méndez, S.
publishDate 2020
publisher.none.fl_str_mv MDPI
repo_facet_str urn:repositoryAcronym:rum{{{_:::_}}}RepositóriUM - Universidade do Minho
reponame_str RepositóriUM - Universidade do Minho
repository_id_str urn:repositoryAcronym:rum
service_str_mv urn:repositoryAcronym:rum
spelling engMDPIporPoly(hydroxybutyrate-co-hydroxyvalerate) (PHBV) is a piezoelectric biodegradable and biocompatible polymer suitable for tissue engineering applications. The incorporation of magnetostrictive cobalt ferrites (CFO) into PHBV matrix enables the production of magnetically responsive composites, which proved to be effective in the differentiation of a variety of cells and tissues. In this work, PHBV and PHBV with CFO nanoparticles were produced in the form of films, fibers and porous scaffolds and subjected to an experimental program allowing to evaluate the degradation process under biological conditions for a period up to 8 weeks. The morphology, physical, chemical and thermal properties were evaluated, together with the weight loss of the samples during the in vitro degradation assays. No major changes in the mentioned properties were found, thus proving its applicability for tissue engineering applications. Degradation was apparent from week 4 and onwards, leading to the conclusion that the degradation ratio of the material is suitable for a large range of tissue engineering applications. Further, it was found that the degradation of the samples maintain the biocompatibility of the materials for the pristine polymer, but can lead to cytotoxic effects when the magnetic CFO nanoparticles are exposed, being therefore needed, for magnetoactive applications, to substitute them by biocompatible ferrites, such as an iron oxide (Fe3O4).application/pdfporMorphology dependence degradation of electro- and magnetoactive poly(3-hydroxybutyrate-co-hydroxyvalerate) for tissue engineering applicationsAmaro, LuisCorreia, Daniela M.Martins, Pedro Manuel AbreuBotelho, GabrielaCarabineiro, Sónia A. C.Ribeiro, Clarisse Marta OliveiraLanceros-Méndez, S.HostingInstitutionOrganizationalRepositóriUM - Universidade do Minhoe-mailmailto:repositorium@usdb.uminho.ptrepositorium@usdb.uminho.ptCITATIONAmaro, Luis; Correia, Daniela M.; Martins, Pedro M.; Botelho, Gabriela; Carabineiro, Sónia A. C.; Ribeiro, Clarisse; Lanceros-Mendez, Senentxu, Morphology dependence degradation of electro- and magnetoactive poly(3-hydroxybutyrate-co-hydroxyvalerate) for tissue engineering applications. Polymers, 12(4), 953, 2020.ISSNIsPartOf2073-4360EISSNIsPartOf2073-4360DOIIsPartOf10.3390/polym120409532020-04-162020-04-16T00:00:00ZHandlehttps://hdl.handle.net/1822/65104http://purl.org/coar/access_right/c_abf2open accesspiezoelectric materialspoly(hydroxybutyrate-co-hydroxyvalerate)hydrolytic degradationtissue engineering3336634 bytesliteraturehttp://purl.org/coar/resource_type/c_6501journal article2020-04-16http://creativecommons.org/licenses/by/4.0/openAccesshttp://purl.org/coar/access_right/c_abf2application/pdfhttps://repositorium.uminho.pt/bitstreams/4e905e87-a4f5-487b-9f14-43d642e23704/download
spellingShingle Morphology dependence degradation of electro- and magnetoactive poly(3-hydroxybutyrate-co-hydroxyvalerate) for tissue engineering applications
Amaro, Luis
piezoelectric materials
poly(hydroxybutyrate-co-hydroxyvalerate)
hydrolytic degradation
tissue engineering
status SINGLETON
subject.fl_str_mv piezoelectric materials
poly(hydroxybutyrate-co-hydroxyvalerate)
hydrolytic degradation
tissue engineering
title Morphology dependence degradation of electro- and magnetoactive poly(3-hydroxybutyrate-co-hydroxyvalerate) for tissue engineering applications
title_full Morphology dependence degradation of electro- and magnetoactive poly(3-hydroxybutyrate-co-hydroxyvalerate) for tissue engineering applications
title_fullStr Morphology dependence degradation of electro- and magnetoactive poly(3-hydroxybutyrate-co-hydroxyvalerate) for tissue engineering applications
title_full_unstemmed Morphology dependence degradation of electro- and magnetoactive poly(3-hydroxybutyrate-co-hydroxyvalerate) for tissue engineering applications
title_short Morphology dependence degradation of electro- and magnetoactive poly(3-hydroxybutyrate-co-hydroxyvalerate) for tissue engineering applications
title_sort Morphology dependence degradation of electro- and magnetoactive poly(3-hydroxybutyrate-co-hydroxyvalerate) for tissue engineering applications
topic piezoelectric materials
poly(hydroxybutyrate-co-hydroxyvalerate)
hydrolytic degradation
tissue engineering
topic_facet piezoelectric materials
poly(hydroxybutyrate-co-hydroxyvalerate)
hydrolytic degradation
tissue engineering
url https://hdl.handle.net/1822/65104
visible 1

Atividades financiadas

Não foram encontrados projetos financiados.