Publicação
The Role of Pedicle Screw Surface on Insertion Torque and Pullout Strength
| Resumo: | Abstract Objective Compare by mechanical tests the pullout resistance and the insertion torque of rough and smooth pedicle screws. Methods Pedicle screws with rough surface and smooth surface, with diameters of 4.8; 5.5 and 6.5 mm, were inserted in polyurethane blocks with density of 10 PCF (0.16 g/cm3). Insertion torque and pullout strength were assessed. Results The pullout strength of the rough surface and smooth surface screws did not differ, except in the group of 4.8 mm diameter screws. In this group, the rough surface screws showed greater resistance to pullout. Conclusion Pedicle screws with a rough surface did not show increased pullout resistance in the acute phase of their insertion in polyurethane blocks compared to smooth surface screws. The rough surface screws had a higher insertion torque than the smooth surface screws, depending on the diameter of the screw and the preparation of the pilot hole. |
|---|---|
| Autores principais: | Fleury,Rodrigo Barra Caiado |
| Outros Autores: | Shimano,Antônio Carlos; Matos,Thiago Dantas; Teixeira,Kelsen de Oliveira; Romero,Valéria; Defino,Helton Luiz Aparecido |
| Assunto: | spine bone screws biomechanical phenomena |
| Ano: | 2020 |
| País: | Brasil |
| Tipo de documento: | artigo |
| Tipo de acesso: | acesso aberto |
| Instituição associada: | IBICT |
| Idioma: | inglês |
| Origem: | Oasisbr |
Registos relacionados
article INFLUENCE OF THE CONGRUENCE OF PILOT HOLE TAPPING ON THE ANCHORAGE OF THE PEDICLE SCREW
por: FLEURY,RODRIGO BARRA CAIADO
Publicado em: (2020)
por: FLEURY,RODRIGO BARRA CAIADO
Publicado em: (2020)
article The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength
por: Pinheiro,Rômulo Pedroza
Publicado em: (2022)
por: Pinheiro,Rômulo Pedroza
Publicado em: (2022)
article DIRECT PEDICLE SCREW INSERTION PULLOUT STRENGTH
por: PINHEIRO,RÔMULO PEDROZA
Publicado em: (2021)
por: PINHEIRO,RÔMULO PEDROZA
Publicado em: (2021)
article INFLUENCE OF DIAMETER AND GEOMETRY IN THE TAPPING OF THE PILOT HOLE IN PEDICLE SCREWS
por: Defino,Helton Luiz Aparecido
Publicado em: (2019)
por: Defino,Helton Luiz Aparecido
Publicado em: (2019)
article MORPHOMETRY OF THE POSITIONING OF CORTICAL TRAJECTORY PEDICLE SCREWS IN BRAZILIANS
por: GOSENDE,FERNANDO MAGALHÃES
Publicado em: (2020)
por: GOSENDE,FERNANDO MAGALHÃES
Publicado em: (2020)
article In vivo studies on flexion and extension of the lumbar spine after stabilisation with a non-fusion pedicle screw system
por: Klauß,Jörg Rainer
Publicado em: (2012)
por: Klauß,Jörg Rainer
Publicado em: (2012)
article Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review
por: Wang, Hongwei
Publicado em: (2017)
por: Wang, Hongwei
Publicado em: (2017)
article ACCURACY OF PEDICLE SCREW INSERTION: A COMPARISON BETWEEN FLUOROSCOPIC GUIDANCE AND NAVIGATION TECHNIQUES
por: Bilhar,Romero Pinto de Oliveira
Publicado em: (2018)
por: Bilhar,Romero Pinto de Oliveira
Publicado em: (2018)
article Tomographic Analysis of the Anatomical Parameters for the Insertion of Cortical Bone Screws
por: Herrero,Carlos Fernando Pereira da Silva
Publicado em: (2022)
por: Herrero,Carlos Fernando Pereira da Silva
Publicado em: (2022)
article Reduction in radiation (fluoroscopy) while maintaining safe placement of pedicle screws during lumbar spine fusion
por: Chaput,Christopher D.
Publicado em: (2013)
por: Chaput,Christopher D.
Publicado em: (2013)
article INTRA- AND INTEROBSERVER ANALYSIS OF PEDICLE SCREW PLACEMENT IN SCOLIOSIS CORRECTION
por: CASTRO,CAÍQUE JAUHAR DE
Publicado em: (2020)
por: CASTRO,CAÍQUE JAUHAR DE
Publicado em: (2020)
article EVIDENCE LEVEL OF THE PLACEMENT OF SCREWS OUTSIDE PEDICLE IN THORACIC AND LUMBAR SPINE
por: Bustos,Gabriel Aldama
Publicado em: (2018)
por: Bustos,Gabriel Aldama
Publicado em: (2018)
article Direct pedicle screw insertion pullout strength
por: Defino, Helton Luiz Aparecido
Publicado em: (2021)
por: Defino, Helton Luiz Aparecido
Publicado em: (2021)
article Morphometry of the positioning of cortical trajectory pedicle screws in brazilians
por: Fernando Magalhãesgosende
Publicado em: (2023)
por: Fernando Magalhãesgosende
Publicado em: (2023)
article Histomorphometric analysis of bone tissue repair in rabbits after insertion of titanium screws under different torque
por: Togni,Fabrício
Publicado em: (2011)
por: Togni,Fabrício
Publicado em: (2011)
article Experimental determination of bone cortex holding power of orthopedic screw
por: Bolliger Neto,Raul
Publicado em: (1999)
por: Bolliger Neto,Raul
Publicado em: (1999)
article Bilateral fracture of L5 pedicles in a patient with total disc replacement of L5-S1: a case report
por: Estrada,Jorge Alberto De Haro
Publicado em: (2014)
por: Estrada,Jorge Alberto De Haro
Publicado em: (2014)
article MINIMALLY INVASIVE LUMBAR ARTHRODESIS AND PERCUTANEOUS PEDICLE SCREWS: A SYSTEMATIC REVIEW
por: BENITES,VINICIUS DE MELDAU
Publicado em: (2020)
por: BENITES,VINICIUS DE MELDAU
Publicado em: (2020)
article Comparison between posterior lumbar fusion with pedicle screws and posterior lumbar interbody fusion with pedicle screws in adult spondylolisthesis
por: Dantas,Fernando Luiz Rolemberg
Publicado em: (2007)
por: Dantas,Fernando Luiz Rolemberg
Publicado em: (2007)
article CHANGES IN THE LUMBAR VERTEBRAL SEGMENT RELATED TO THE CAGE POSITION IN TLIF TECHNIQUE
por: MATOS,THIAGO DANTAS
Publicado em: (2020)
por: MATOS,THIAGO DANTAS
Publicado em: (2020)
article Chronic low back pain and walking speed: effects on the spatiotemporal parameters and in gait variability
por: Carvalho,Alberito Rodrigo
Publicado em: (2019)
por: Carvalho,Alberito Rodrigo
Publicado em: (2019)
article ONE OR TWO SCREWS IN THE FRACTURE OF THE ODONTOID PROCESS? EVALUATION USING COMPUTED TOMOGRAPHY
por: Amaral,Carlos Alexandre Botelho do
Publicado em: (2015)
por: Amaral,Carlos Alexandre Botelho do
Publicado em: (2015)
article DOES THE USE OF DYNAMIC SURGICAL GUIDANCE ASSIST ACCURATE PEDICLE SCREW PLACEMENT IN PATIENTS WITH OSTEOPOROSIS OR OSTEOPENIA?
por: DEFINO,HELTON L A
Publicado em: (2020)
por: DEFINO,HELTON L A
Publicado em: (2020)
article Positioning of pedicle screws in adolescent idiopathic scoliosis using electromyography
por: Gavassi,Bruno Moreira
Publicado em: (2015)
por: Gavassi,Bruno Moreira
Publicado em: (2015)
article Free-hand placement of high thoracic pedicle screws with the aid of fluoroscopy: evaluation of positioning by CT scans in a four-year consecutive series
por: Braga,Bruno Perocco
Publicado em: (2010)
por: Braga,Bruno Perocco
Publicado em: (2010)
article Anatomical study of lumbar vertebral pedicle and adjacent neural structures
por: Matuoka,Cláudia Maria
Publicado em: (2002)
por: Matuoka,Cláudia Maria
Publicado em: (2002)
article Are Anterior Plates More Effective than Iliosacral Screws to Fix the Sacroiliac Joint? Biomechanical Study
por: Goldsztajn,Flavio
Publicado em: (2020)
por: Goldsztajn,Flavio
Publicado em: (2020)
article Sacroiliac secure corridor: analysis for safe insertion of iliosacral screws
por: Cruz,Henrique Alves
Publicado em: (2013)
por: Cruz,Henrique Alves
Publicado em: (2013)
article Anatomic considerations for C2 pedicle screw placement: the use of computerized tomography measurements
por: Onibokun,Adebukoa
Publicado em: (2009)
por: Onibokun,Adebukoa
Publicado em: (2009)
article Effect of abutment screw surface treatment on reliability of implant-supported crowns
por: Anchieta, Rodolfo Bruniera
Publicado em: (2022)
por: Anchieta, Rodolfo Bruniera
Publicado em: (2022)
article Pedicle Screws and Facet Violation - The importance of the Angle between the Facet and the Screw
por: Amaral,Rodrigo
Publicado em: (2020)
por: Amaral,Rodrigo
Publicado em: (2020)
article CORRELATION BETWEEN QUALITY OF LIFE AND OSTEOLYSIS AROUND LUMBAR PEDICLE SCREWS
por: RISSO NETO,MARCELO ITALO
Publicado em: (2016)
por: RISSO NETO,MARCELO ITALO
Publicado em: (2016)
article FINITE ELEMENT ANALYSIS OF THORACIC VERTEBRAL STABILITY SUPPORTED BY THE FOURTH SPINE
por: Silva,Javier Andrés Martínez
Publicado em: (2022)
por: Silva,Javier Andrés Martínez
Publicado em: (2022)
article Sagittal curve and high metal density in adolescent idiopathic scoliosis
por: Fernandes,Fabio Araújo
Publicado em: (2014)
por: Fernandes,Fabio Araújo
Publicado em: (2014)
article Clinical evaluation of a bone cement-injectable cannulated pedicle screw augmented with polymethylmethacrylate: 128 osteoporotic patients with 42 months of follow-up
por: Wang, Zhengdong
Publicado em: (2019)
por: Wang, Zhengdong
Publicado em: (2019)
assignment Thoracolumbar Chance fracture during a professional female soccer game: case report
por: Gotfryd,Alberto Ofenhejm
Publicado em: (2016)
por: Gotfryd,Alberto Ofenhejm
Publicado em: (2016)
article Complications Relating to Accuracy of Reduction of Intertrochanteric Fractures Treated with a Compressive Hip Screw
por: Guerra Pinto, F
Publicado em: (2010)
por: Guerra Pinto, F
Publicado em: (2010)
article Graft tendon slippage with metallic and bioabsorbable interference screws under cyclic load: a biomechanical study in a porcine model
por: Moré,Ari Digiácomo Ocampo
Publicado em: (2015)
por: Moré,Ari Digiácomo Ocampo
Publicado em: (2015)
article FREE-HAND PLACEMENT OF C7 PEDICLE SCREWS: A CADAVERIC STUDY
por: Vialle,Emiliano
Publicado em: (2015)
por: Vialle,Emiliano
Publicado em: (2015)
article Pedicle screw rupture: A case study
por: Giacaglia, Giorgio Eugenio Oscare
Publicado em: (2019)
por: Giacaglia, Giorgio Eugenio Oscare
Publicado em: (2019)
Atividades financiadas
Não foram encontrados projetos financiados.
Registos relacionados
-
article INFLUENCE OF THE CONGRUENCE OF PILOT HOLE TAPPING ON THE ANCHORAGE OF THE PEDICLE SCREW
por: FLEURY,RODRIGO BARRA CAIADO
Publicado em: (2020) -
article The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength
por: Pinheiro,Rômulo Pedroza
Publicado em: (2022) -
article DIRECT PEDICLE SCREW INSERTION PULLOUT STRENGTH
por: PINHEIRO,RÔMULO PEDROZA
Publicado em: (2021) -
article INFLUENCE OF DIAMETER AND GEOMETRY IN THE TAPPING OF THE PILOT HOLE IN PEDICLE SCREWS
por: Defino,Helton Luiz Aparecido
Publicado em: (2019) -
article MORPHOMETRY OF THE POSITIONING OF CORTICAL TRAJECTORY PEDICLE SCREWS IN BRAZILIANS
por: GOSENDE,FERNANDO MAGALHÃES
Publicado em: (2020)