Publication

Visual acuity, contrast sensitivity, and quality of life after bilateral implantation of multifocal diffractive intraocular lens

View document

Bibliographic Details
Summary:ABSTRACT Purpose: To evaluate visual outcomes, satisfaction, and quality of life of patients assisted in a Medical School hospital by the Brazilian Public Health System, who underwent bilateral diffractive multifocal intraocular lens implantation. Methods: Case series study with intervention, including 20 patients who underwent bilateral implantation of multifocal IOL EyeDiff® (Eyeol UK, Dunstable, UK). Exclusion criteria were corneal astigmatism >1.5 cylindrical diopters, previous ocular surgery or ocular disease, and intra- or postoperative complications. Patients were evaluated one, three, and six months after surgery. Monocular and binocular visual acuity for distance, intermediate and near, under photopic and mesopic conditions, monocular contrast sensitivity under photopic conditions, defocus curve, and quality of life were assessed. Results: Monocular distance-corrected visual acuity was 0.3 logMAR or better and monocular distance-corrected near visual acuity was J3 or better in all eyes under photopic conditions. Binocular distance-corrected near visual acuity was J1 in all cases. Contrast sensitivity was at the minimum level of normality for low and high spatial frequencies and within normal limits for intermediate spatial frequency. The quality of life questionnaire showed a high level of patient satisfaction. Conclusion: Bilateral implantation of the multifocal intraocular lens EyeDiff® provides patients with good visual acuity and quality of life, besides spectacle independence. The visual acuity and contrast sensitivity progressively improved between one and six postoperative months.
Main Authors:Queiroz,Marjorie F. N
Other Authors:Ferreira,Felipe Q. T; Shimoda,Gilberto; Padovani,Carlos Roberto; Lottelli,Antonio C
Subject:Visual acuity Quality of life Patient satisfaction Lens implantation intraocular Unified Health System
Year:2022
Country:Brazil
Document type:article
Access type:open access
Associated institution:IBICT
Language:English
Origin:Oasisbr
_version_ 1871509983131074560
author Queiroz,Marjorie F. N
author2 Ferreira,Felipe Q. T
Shimoda,Gilberto
Padovani,Carlos Roberto
Lottelli,Antonio C
author2_role author
author
author
author
author_facet Queiroz,Marjorie F. N
Ferreira,Felipe Q. T
Shimoda,Gilberto
Padovani,Carlos Roberto
Lottelli,Antonio C
author_role author
country_str BR
creators_json_txt [{\"Person.name\":\"Queiroz,Marjorie F. N\"},{\"Person.name\":\"Ferreira,Felipe Q. T\"},{\"Person.name\":\"Shimoda,Gilberto\"},{\"Person.name\":\"Padovani,Carlos Roberto\"},{\"Person.name\":\"Lottelli,Antonio C\"}]
datacite.creators.creator.creatorName.fl_str_mv Queiroz,Marjorie F. N
Ferreira,Felipe Q. T
Shimoda,Gilberto
Padovani,Carlos Roberto
Lottelli,Antonio C
datacite.rights.fl_str_mv http://purl.org/coar/access_right/c_abf2
datacite.subjects.subject.fl_str_mv Visual acuity
Quality of life
Patient satisfaction
Lens implantation
intraocular
Unified Health System
datacite.titles.title.fl_str_mv Visual acuity, contrast sensitivity, and quality of life after bilateral implantation of multifocal diffractive intraocular lens
dc.creator.none.fl_str_mv Queiroz,Marjorie F. N
Ferreira,Felipe Q. T
Shimoda,Gilberto
Padovani,Carlos Roberto
Lottelli,Antonio C
dc.format.none.fl_str_mv text/html
dc.identifier.none.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492022005005220
dc.language.none.fl_str_mv eng
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.rights.none.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia n.ahead 2022
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
dc.subject.none.fl_str_mv Visual acuity
Quality of life
Patient satisfaction
Lens implantation
intraocular
Unified Health System
dc.title.fl_str_mv Visual acuity, contrast sensitivity, and quality of life after bilateral implantation of multifocal diffractive intraocular lens
dc.type.none.fl_str_mv http://purl.org/coar/resource_type/c_6501
description ABSTRACT Purpose: To evaluate visual outcomes, satisfaction, and quality of life of patients assisted in a Medical School hospital by the Brazilian Public Health System, who underwent bilateral diffractive multifocal intraocular lens implantation. Methods: Case series study with intervention, including 20 patients who underwent bilateral implantation of multifocal IOL EyeDiff® (Eyeol UK, Dunstable, UK). Exclusion criteria were corneal astigmatism >1.5 cylindrical diopters, previous ocular surgery or ocular disease, and intra- or postoperative complications. Patients were evaluated one, three, and six months after surgery. Monocular and binocular visual acuity for distance, intermediate and near, under photopic and mesopic conditions, monocular contrast sensitivity under photopic conditions, defocus curve, and quality of life were assessed. Results: Monocular distance-corrected visual acuity was 0.3 logMAR or better and monocular distance-corrected near visual acuity was J3 or better in all eyes under photopic conditions. Binocular distance-corrected near visual acuity was J1 in all cases. Contrast sensitivity was at the minimum level of normality for low and high spatial frequencies and within normal limits for intermediate spatial frequency. The quality of life questionnaire showed a high level of patient satisfaction. Conclusion: Bilateral implantation of the multifocal intraocular lens EyeDiff® provides patients with good visual acuity and quality of life, besides spectacle independence. The visual acuity and contrast sensitivity progressively improved between one and six postoperative months.
dirty 0
eu_rights_str_mv openAccess
format article
id oasisbr_d5c8353f0a71c891fd6ddeb7bdcf0e08
identifier.url.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492022005005220
inst_facet_str urn:organizationAcronym:oasisbr{{{_:::_}}}IBICT
instacron_str OASISBR
institution IBICT
instname_str IBICT
language eng
network_acronym_str oasisbr
network_name_str Oasisbr
oai_identifier_str oai:scielo:S0004-27492022005005220
organization_str_mv urn:organizationAcronym:oasisbr
person_str_mv Queiroz,Marjorie F. N
Ferreira,Felipe Q. T
Shimoda,Gilberto
Padovani,Carlos Roberto
Lottelli,Antonio C
publishDate 2022
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
repo_facet_str urn:repositoryAcronym:oasisbr{{{_:::_}}}Oasisbr
reponame_str Oasisbr
repository_id_str urn:repositoryAcronym:oasisbr
service_str_mv urn:repositoryAcronym:oasisbr
spelling Visual acuity, contrast sensitivity, and quality of life after bilateral implantation of multifocal diffractive intraocular lensQueiroz,Marjorie F. NFerreira,Felipe Q. TShimoda,GilbertoPadovani,Carlos RobertoLottelli,Antonio CVisual acuityQuality of lifePatient satisfactionLens implantationintraocularUnified Health Systemopen accesshttp://purl.org/coar/access_right/c_abf2http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492022005005220URLhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492022005005220URLHasVersion2022-01-01ABSTRACT Purpose: To evaluate visual outcomes, satisfaction, and quality of life of patients assisted in a Medical School hospital by the Brazilian Public Health System, who underwent bilateral diffractive multifocal intraocular lens implantation. Methods: Case series study with intervention, including 20 patients who underwent bilateral implantation of multifocal IOL EyeDiff® (Eyeol UK, Dunstable, UK). Exclusion criteria were corneal astigmatism >1.5 cylindrical diopters, previous ocular surgery or ocular disease, and intra- or postoperative complications. Patients were evaluated one, three, and six months after surgery. Monocular and binocular visual acuity for distance, intermediate and near, under photopic and mesopic conditions, monocular contrast sensitivity under photopic conditions, defocus curve, and quality of life were assessed. Results: Monocular distance-corrected visual acuity was 0.3 logMAR or better and monocular distance-corrected near visual acuity was J3 or better in all eyes under photopic conditions. Binocular distance-corrected near visual acuity was J1 in all cases. Contrast sensitivity was at the minimum level of normality for low and high spatial frequencies and within normal limits for intermediate spatial frequency. The quality of life questionnaire showed a high level of patient satisfaction. Conclusion: Bilateral implantation of the multifocal intraocular lens EyeDiff® provides patients with good visual acuity and quality of life, besides spectacle independence. The visual acuity and contrast sensitivity progressively improved between one and six postoperative months.engtext/htmlConselho Brasileiro de OftalmologiaArquivos Brasileiros de Oftalmologia n.ahead 2022reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBOjournal articlehttp://purl.org/coar/resource_type/c_6501literatureVoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85
spellingShingle Visual acuity, contrast sensitivity, and quality of life after bilateral implantation of multifocal diffractive intraocular lens
Queiroz,Marjorie F. N
Visual acuity
Quality of life
Patient satisfaction
Lens implantation
intraocular
Unified Health System
status SINGLETON
status_str VoR
subject.fl_str_mv Visual acuity
Quality of life
Patient satisfaction
Lens implantation
intraocular
Unified Health System
title Visual acuity, contrast sensitivity, and quality of life after bilateral implantation of multifocal diffractive intraocular lens
title_full Visual acuity, contrast sensitivity, and quality of life after bilateral implantation of multifocal diffractive intraocular lens
title_fullStr Visual acuity, contrast sensitivity, and quality of life after bilateral implantation of multifocal diffractive intraocular lens
title_full_unstemmed Visual acuity, contrast sensitivity, and quality of life after bilateral implantation of multifocal diffractive intraocular lens
title_short Visual acuity, contrast sensitivity, and quality of life after bilateral implantation of multifocal diffractive intraocular lens
title_sort Visual acuity, contrast sensitivity, and quality of life after bilateral implantation of multifocal diffractive intraocular lens
topic Visual acuity
Quality of life
Patient satisfaction
Lens implantation
intraocular
Unified Health System
topic_facet Visual acuity
Quality of life
Patient satisfaction
Lens implantation
intraocular
Unified Health System
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492022005005220
visible 1

Funded activities

No funded projects found.