Publicação

Prevalence of corneal astigmatism in cataract surgery candidates at a public hospital in Brazil

Ver documento

Detalhes bibliográficos
Resumo:ABSTRACT Purpose: To assess the frequency of corneal astigmatism before cataract surgery in a Brazilian sample. Methods: This clinic-based cross-sectional study was conducted at the Bonsucesso Federal Hospital, Rio de Janeiro, Brazil. Charts of patients who underwent cataract surgery over a two-year period were retrospectively reviewed, and preoperative keratometric measurements were collected and analyzed. Results: A total of 1707 eyes of 1045 patients were enrolled. The corneal astigmatism was less than 1.0 D in 971 eyes (56.9%), 1.0-1.99 D in 496 eyes (29.1%), 2.0-2.99 D in 157 eyes (9.2%), and more than 3.0 D in 83 eyes (4.9%). The mean corneal astigmatism was 0.92 ± (SD) 0.96 D (range 0 - 10.25 D). Conclusion: Over 40% of the patients undergoing cataract surgery enrolled in this study had more than 1.0 D of corneal astigmatism and may benefit from the use of toric intraocular lenses. These data can be useful for planning to make this technology available for patients.
Autores principais:Theiss,Mara Barreto
Outros Autores:Santhiago,Marcony R.; Moraes Jr,Haroldo V.; Gomes,Beatriz Fiuza
Assunto:Astigmatism/epidemiology Cataract extraction/adverse effects Lenses, intraocular Cross-sectional study Brazil
Ano:2019
País:Brasil
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:IBICT
Idioma:inglês
Origem:Oasisbr
Descrição
Resumo:ABSTRACT Purpose: To assess the frequency of corneal astigmatism before cataract surgery in a Brazilian sample. Methods: This clinic-based cross-sectional study was conducted at the Bonsucesso Federal Hospital, Rio de Janeiro, Brazil. Charts of patients who underwent cataract surgery over a two-year period were retrospectively reviewed, and preoperative keratometric measurements were collected and analyzed. Results: A total of 1707 eyes of 1045 patients were enrolled. The corneal astigmatism was less than 1.0 D in 971 eyes (56.9%), 1.0-1.99 D in 496 eyes (29.1%), 2.0-2.99 D in 157 eyes (9.2%), and more than 3.0 D in 83 eyes (4.9%). The mean corneal astigmatism was 0.92 ± (SD) 0.96 D (range 0 - 10.25 D). Conclusion: Over 40% of the patients undergoing cataract surgery enrolled in this study had more than 1.0 D of corneal astigmatism and may benefit from the use of toric intraocular lenses. These data can be useful for planning to make this technology available for patients.

Atividades financiadas

Não foram encontrados projetos financiados.