Publication

The evaluation of postoperative objective and subjective refraction for premium intraocular lenses

View document

Bibliographic Details
Summary:Abstract Purpose: To evaluate six different premium IOLs retrospectively in respect to both subjective and objective refraction after cataract operation. Methods: Five hundreds and seventy eyes of 285 patients with bilateral cataract who had undergone phacoemulsification and IOL implantation operation between February 2017 and September 2018 were enrolled in this study. The mean age of the patients was 57.78 ± 7.49 (41-71) years. Out of 285 patients 137 were male (48.07%) and 148 were female (51.93%). TheIOLsusedare: RayOne Trifocal (Rayner, Worthing, UK), Lucidis (Swiss Advanced Vision, Neuchâtel, Switzerland), PanOptix (Alcon, Fort Worth, USA), LentisMplus (Oculentis, Berlin, Germany), TecnisSymfony (Abbott, Illinois, USA) and Acriva Trinova (VSY Biotechnology, Istanbul, Turkey). Results: There were no significant differences among the groups regarding age, sex, axial length, the mean preoperative and postoperative uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), the mean preoperative spherical equivalent (SE) and the mean postoperative SE (subjective measurement) (P> .05). The postoperative refractions measured with autorefractometer were more myopic than subjective refractions in all patients except the patients who had PanOptix IOL. In postoperative twelfth month, the mean UCVA arrived 0.00 logMAR in 405 eyes (78.48%) , however, the mean autorefractometric measurement was -1.28 ± 1.02 (0.00_-2.75) D. Conclusion: The autorefractometer measurements of all patients who had premium IOLs except PanOptix IOL were not coherent with their visual acuities postoperatively. The ophthalmologists and/or optometrists should be careful while examining these types of patients.
Main Authors:Ucar,Fikret
Other Authors:Cetinkaya,Servet
Subject:Lenses, intraocular Objective refraction Subjective refraction Visual acuity
Year:2020
Country:Brazil
Document type:article
Access type:open access
Associated institution:IBICT
Language:English
Origin:Oasisbr
_version_ 1871507180145868800
author Ucar,Fikret
author2 Cetinkaya,Servet
author2_role author
author_facet Ucar,Fikret
Cetinkaya,Servet
author_role author
country_str BR
creators_json_txt [{\"Person.name\":\"Ucar,Fikret\"},{\"Person.name\":\"Cetinkaya,Servet\"}]
datacite.creators.creator.creatorName.fl_str_mv Ucar,Fikret
Cetinkaya,Servet
datacite.rights.fl_str_mv http://purl.org/coar/access_right/c_abf2
datacite.subjects.subject.fl_str_mv Lenses, intraocular
Objective refraction
Subjective refraction
Visual acuity
datacite.titles.title.fl_str_mv The evaluation of postoperative objective and subjective refraction for premium intraocular lenses
dc.creator.none.fl_str_mv Ucar,Fikret
Cetinkaya,Servet
dc.format.none.fl_str_mv text/html
dc.identifier.none.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802020000600386
dc.language.none.fl_str_mv eng
dc.publisher.none.fl_str_mv Sociedade Brasileira de Oftalmologia
dc.rights.none.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.source.none.fl_str_mv Revista Brasileira de Oftalmologia v.79 n.6 2020
reponame:Revista Brasileira de Oftalmologia (Online)
instname:Sociedade Brasileira de Oftalmologia (SBO)
instacron:SBO
dc.subject.none.fl_str_mv Lenses, intraocular
Objective refraction
Subjective refraction
Visual acuity
dc.title.fl_str_mv The evaluation of postoperative objective and subjective refraction for premium intraocular lenses
dc.type.none.fl_str_mv http://purl.org/coar/resource_type/c_6501
description Abstract Purpose: To evaluate six different premium IOLs retrospectively in respect to both subjective and objective refraction after cataract operation. Methods: Five hundreds and seventy eyes of 285 patients with bilateral cataract who had undergone phacoemulsification and IOL implantation operation between February 2017 and September 2018 were enrolled in this study. The mean age of the patients was 57.78 ± 7.49 (41-71) years. Out of 285 patients 137 were male (48.07%) and 148 were female (51.93%). TheIOLsusedare: RayOne Trifocal (Rayner, Worthing, UK), Lucidis (Swiss Advanced Vision, Neuchâtel, Switzerland), PanOptix (Alcon, Fort Worth, USA), LentisMplus (Oculentis, Berlin, Germany), TecnisSymfony (Abbott, Illinois, USA) and Acriva Trinova (VSY Biotechnology, Istanbul, Turkey). Results: There were no significant differences among the groups regarding age, sex, axial length, the mean preoperative and postoperative uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), the mean preoperative spherical equivalent (SE) and the mean postoperative SE (subjective measurement) (P> .05). The postoperative refractions measured with autorefractometer were more myopic than subjective refractions in all patients except the patients who had PanOptix IOL. In postoperative twelfth month, the mean UCVA arrived 0.00 logMAR in 405 eyes (78.48%) , however, the mean autorefractometric measurement was -1.28 ± 1.02 (0.00_-2.75) D. Conclusion: The autorefractometer measurements of all patients who had premium IOLs except PanOptix IOL were not coherent with their visual acuities postoperatively. The ophthalmologists and/or optometrists should be careful while examining these types of patients.
dirty 0
eu_rights_str_mv openAccess
format article
id oasisbr_20c698eed55cdcc73f44ee3806ca2d83
identifier.url.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802020000600386
inst_facet_str urn:organizationAcronym:oasisbr{{{_:::_}}}IBICT
instacron_str OASISBR
institution IBICT
instname_str IBICT
language eng
network_acronym_str oasisbr
network_name_str Oasisbr
oai_identifier_str oai:scielo:S0034-72802020000600386
organization_str_mv urn:organizationAcronym:oasisbr
person_str_mv Ucar,Fikret
Cetinkaya,Servet
publishDate 2020
publisher.none.fl_str_mv Sociedade Brasileira de Oftalmologia
repo_facet_str urn:repositoryAcronym:oasisbr{{{_:::_}}}Oasisbr
reponame_str Oasisbr
repository_id_str urn:repositoryAcronym:oasisbr
service_str_mv urn:repositoryAcronym:oasisbr
spelling The evaluation of postoperative objective and subjective refraction for premium intraocular lensesUcar,FikretCetinkaya,ServetLenses, intraocularObjective refractionSubjective refractionVisual acuityopen accesshttp://purl.org/coar/access_right/c_abf2http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802020000600386URLhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802020000600386URLHasVersion2020-12-01Abstract Purpose: To evaluate six different premium IOLs retrospectively in respect to both subjective and objective refraction after cataract operation. Methods: Five hundreds and seventy eyes of 285 patients with bilateral cataract who had undergone phacoemulsification and IOL implantation operation between February 2017 and September 2018 were enrolled in this study. The mean age of the patients was 57.78 ± 7.49 (41-71) years. Out of 285 patients 137 were male (48.07%) and 148 were female (51.93%). TheIOLsusedare: RayOne Trifocal (Rayner, Worthing, UK), Lucidis (Swiss Advanced Vision, Neuchâtel, Switzerland), PanOptix (Alcon, Fort Worth, USA), LentisMplus (Oculentis, Berlin, Germany), TecnisSymfony (Abbott, Illinois, USA) and Acriva Trinova (VSY Biotechnology, Istanbul, Turkey). Results: There were no significant differences among the groups regarding age, sex, axial length, the mean preoperative and postoperative uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), the mean preoperative spherical equivalent (SE) and the mean postoperative SE (subjective measurement) (P> .05). The postoperative refractions measured with autorefractometer were more myopic than subjective refractions in all patients except the patients who had PanOptix IOL. In postoperative twelfth month, the mean UCVA arrived 0.00 logMAR in 405 eyes (78.48%) , however, the mean autorefractometric measurement was -1.28 ± 1.02 (0.00_-2.75) D. Conclusion: The autorefractometer measurements of all patients who had premium IOLs except PanOptix IOL were not coherent with their visual acuities postoperatively. The ophthalmologists and/or optometrists should be careful while examining these types of patients.engtext/htmlSociedade Brasileira de OftalmologiaRevista Brasileira de Oftalmologia v.79 n.6 2020reponame:Revista Brasileira de Oftalmologia (Online)instname:Sociedade Brasileira de Oftalmologia (SBO)instacron:SBOjournal articlehttp://purl.org/coar/resource_type/c_6501literatureVoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85
spellingShingle The evaluation of postoperative objective and subjective refraction for premium intraocular lenses
Ucar,Fikret
Lenses, intraocular
Objective refraction
Subjective refraction
Visual acuity
status SINGLETON
status_str VoR
subject.fl_str_mv Lenses, intraocular
Objective refraction
Subjective refraction
Visual acuity
title The evaluation of postoperative objective and subjective refraction for premium intraocular lenses
title_full The evaluation of postoperative objective and subjective refraction for premium intraocular lenses
title_fullStr The evaluation of postoperative objective and subjective refraction for premium intraocular lenses
title_full_unstemmed The evaluation of postoperative objective and subjective refraction for premium intraocular lenses
title_short The evaluation of postoperative objective and subjective refraction for premium intraocular lenses
title_sort The evaluation of postoperative objective and subjective refraction for premium intraocular lenses
topic Lenses, intraocular
Objective refraction
Subjective refraction
Visual acuity
topic_facet Lenses, intraocular
Objective refraction
Subjective refraction
Visual acuity
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802020000600386
visible 1

Funded activities

No funded projects found.