Publication

Anticorpos Monoclonais contra Listeria spp.: Produção, Caracterização e Aplicação em Métodos Diagnósticos

View document

Bibliographic Details
Summary:The conventional methods used to detect the Listeria monocytogenes in foods are laborious and expensive, requiring several days for final identification. Monoclonal antibody (MAb) based immunoassays are highly specific and rapid to perform, especially when MAbs are raised to conserved virulence factors in the pathogen. Among diverse virulence factors of L. monocytogenes, the surface protein internalin A (InlA) is one of the most well-known and characterized protein, being an excellent target as it is highly exposed on the surface and exclusive of pathogenic species. In this work we report the production, characterization and use of a panel of MAbs against InlA (2D12, 3B7, 4E4), and a MAb (3F8) which specifically recognizes all bacteria belonging the genus Listeria. MAbs were produced by the immunization of BALB/c mice with a recombinant InlA together with heat killed L. monocytogenes. The MAbs produced showed excellent reativities by indirect ELISA, Western blot and immunofluorescence. A Cy5 conjugated anti-InlA MAb-2D12 was used as detection antibody for L. monocytogenes in a sandwich-like fiber optic immunoassay. Using MAb-2D12 as capture antibody on the waveguides, the limit of detection was ~3 x 102 CFU.mL-1, and when MAb-3F8 was used for capture the limit of detection was ~1 x 105 CFU.mL-1. Furthermore, MAbs 2D12 and 3F8 were used to coat paramagnetic beads and tested in the immunomagnetic separation (IMS) of L. monocytogenes from pure cultures, and artificially contaminated cheeses and hotdogs. After IMS capture, bacteria were released from the beads, used in the fiber optic assay or plated on agar for counting. In parallel, the capture of L. monocytogenes was confirmed by real-time qPCR and light-scattering technology (BARDOT). Using IMS to concentrate and separate L. monocytogenes, followed by a fiber optic platform, it was possible to detect in less than 22 h, approximately 40 CFU/g of L. monocytogenesi, even in the presence of L. innocua in cheese and hot dogs artificially contaminated. In addition, using mass spectrometry (MALDI-TOF-MS) the protein to which MAb-3F8 binds, was identified as fructose 1,6-bisphosphate aldolase (FBA). The results presented in this work indicate that using both systems together, the IMS and fiber optic immunosensor, were more reliable and faster, and could be applied in the routinely for detection of L. monocytogenes in food. Moreover, both MAbs have the potential to useful in others biosensor platforms, as well as in other detection and functionality immunoassays for InlA and FBA in Listeria.
Main Authors:Mendonça, Marcelo
Subject:L. monocytogenes Internalina A Anticorpos monoclonais Imunoseparação magnética Sensor de fibra ótica L. monocytogenes Internalin A Monoclonal antibody Immunomagnetic separation Fiber optic sensor CNPQ::CIENCIAS BIOLOGICAS::IMUNOLOGIA
Year:2014
Country:Brazil
Document type:doctoral thesis
Access type:open access
Associated institution:IBICT
Language:Portuguese
Origin:Oasisbr
_version_ 1871530301272883200
author Mendonça, Marcelo
author_facet Mendonça, Marcelo
author_role author
country_str BR
creators_json_txt [{\"Person.name\":\"Mendonça, Marcelo\"}]
datacite.creators.creator.creatorName.fl_str_mv Mendonça, Marcelo
datacite.date.Accepted.fl_str_mv 2014-08-20T13:33:00Z
datacite.date.available.fl_str_mv 2012-04-26T00:00:00Z
datacite.date.embargoed.fl_str_mv 2012-04-26T00:00:00Z
datacite.rights.fl_str_mv http://purl.org/coar/access_right/c_abf2
datacite.subjects.subject.fl_str_mv L. monocytogenes
Internalina A
Anticorpos monoclonais
Imunoseparação magnética
Sensor de fibra ótica
L. monocytogenes
Internalin A
Monoclonal antibody
Immunomagnetic separation
Fiber optic sensor
CNPQ::CIENCIAS BIOLOGICAS::IMUNOLOGIA
datacite.titles.title.fl_str_mv Anticorpos Monoclonais contra Listeria spp.: Produção, Caracterização e Aplicação em Métodos Diagnósticos
Monoclonal Antibodies againstListeria spp.: Production, Characterization and Application in Diagnostic Methods
dc.creator.none.fl_str_mv Mendonça, Marcelo
dc.date.Accepted.fl_str_mv 2014-08-20T13:33:00Z
dc.date.available.fl_str_mv 2012-04-26T00:00:00Z
dc.date.embargoed.fl_str_mv 2012-04-26T00:00:00Z
dc.description.none.fl_str_mv Os métodos convencionais empregados para detecção de Listeria monocytogenes em alimentos são laboriosos e onerosos, requerendo vários dias para sua identificação final. A utilização de anticorpos monoclonais (MAbs) em imunoensaios para detecção rápida de bactérias tem como vantagem a alta especificidade e rapidez, principalmente quando direcionados para fatores de virulência conservados. Dentre os diversos fatores de virulência de Listeria, a proteína de membrana internalina A (InlA), é umas das mais bem caracterizadas, sendo um excelente alvo por ser altamente exposta na superfície e exclusiva de espécies patogênicas. Neste trabalho é relatado a produção, caracterização e utilização em métodos de diagnósticos de um painel de MAbs contra a InlA (2D12, 3B7, 4E4), e de um MAb (3F8) que reconhece especificamente todas as bactérias do gênero Listeria. Na produção dos MAbs, camundongos BALB/c foram imunizados com uma proteína recombinante InlA (rInlA) concomitantemente com L. monocytogenes inativadas por fervura. Os MAbs gerados demonstraram excelente reatividade por ELISA indireto, Western blot e imunofluorescência. O MAb anti-InlA 2D12 marcado com Cy5 foi usado como anticorpo de detecção de L. monocytogenes, no sistema tipo sanduíche de sensor de fibra óptica. Usando MAb-2D12 como anticorpo de captura nas fibras ópticas, obteve-se um limite de detecção de ~3 x 102 CFU.mL-1, e um limite de detecção de ~1 x 105 CFU.mL-1 foi visualizado com MAb-3F8 como captura. Os MAbs anti-InlA 2D12 e anti-Listeria 3F8 foram posteriormente utilizados para sensibilizar esferas paramagnéticas e testados na separação imunomagnética (IMS) de L. monocytogenes em culturas puras, e em queijo e salsichas tipo hotdog artificialmente contaminados. Após a captura por IMS, as bactérias foram liberadas, incubadas com a fibra óptica ou plaqueadas em agares para contagem. Em paralelo, a confirmação da captura de L. monocytogenes foi realizada por PCR quantitativo em tempo real e por light-scattering technology (BARDOT). Utilizando IMS para separar e concentrar L. monocytogenes, seguido da utilização em plataforma de fibra óptica, foi possível realizar a detecção em menos de 22 horas, de aproximadamente 40 UFC/g de L. monocytogenes em presença de L. innocua, em queijo e salsicha artificialmente contaminados. Além disso, a proteína alvo do MAb3F8 foi identificado como frutose 1,6-bifosfato aldolase através de espectrometria de massa (MALDI-TOF-MS). Os resultados obtidos nesse trabalho indicam que a utilização em conjunto dos sistemas de IMS e fibra óptica com os MAb-2D12 e MAb3F8, foram confiáveis e rápidos, e assim, podendo ser empregados em imunoensaios de rotina para detecção de L. monocytogenes em alimentos. Contudo, ambos MAbs possuem ainda grande potencial para serem mais explorados em outras plataformas de biossensores, assim como, em outros imunoensaios de detecção e funcionalidade de InlA e FBA em Listeria
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://repositorio.ufpel.edu.br/handle/ri/1299
dc.language.none.fl_str_mv por
dc.publisher.none.fl_str_mv Universidade Federal de Pelotas
Programa de Pós-Graduação em Biotecnologia
UFPel
BR
Biotecnologia
dc.rights.none.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFPel - Guaiaca
instname:Universidade Federal de Pelotas (UFPEL)
instacron:UFPEL
dc.subject.none.fl_str_mv L. monocytogenes
Internalina A
Anticorpos monoclonais
Imunoseparação magnética
Sensor de fibra ótica
L. monocytogenes
Internalin A
Monoclonal antibody
Immunomagnetic separation
Fiber optic sensor
CNPQ::CIENCIAS BIOLOGICAS::IMUNOLOGIA
dc.title.fl_str_mv Anticorpos Monoclonais contra Listeria spp.: Produção, Caracterização e Aplicação em Métodos Diagnósticos
Monoclonal Antibodies againstListeria spp.: Production, Characterization and Application in Diagnostic Methods
dc.type.none.fl_str_mv http://purl.org/coar/resource_type/c_db06
description The conventional methods used to detect the Listeria monocytogenes in foods are laborious and expensive, requiring several days for final identification. Monoclonal antibody (MAb) based immunoassays are highly specific and rapid to perform, especially when MAbs are raised to conserved virulence factors in the pathogen. Among diverse virulence factors of L. monocytogenes, the surface protein internalin A (InlA) is one of the most well-known and characterized protein, being an excellent target as it is highly exposed on the surface and exclusive of pathogenic species. In this work we report the production, characterization and use of a panel of MAbs against InlA (2D12, 3B7, 4E4), and a MAb (3F8) which specifically recognizes all bacteria belonging the genus Listeria. MAbs were produced by the immunization of BALB/c mice with a recombinant InlA together with heat killed L. monocytogenes. The MAbs produced showed excellent reativities by indirect ELISA, Western blot and immunofluorescence. A Cy5 conjugated anti-InlA MAb-2D12 was used as detection antibody for L. monocytogenes in a sandwich-like fiber optic immunoassay. Using MAb-2D12 as capture antibody on the waveguides, the limit of detection was ~3 x 102 CFU.mL-1, and when MAb-3F8 was used for capture the limit of detection was ~1 x 105 CFU.mL-1. Furthermore, MAbs 2D12 and 3F8 were used to coat paramagnetic beads and tested in the immunomagnetic separation (IMS) of L. monocytogenes from pure cultures, and artificially contaminated cheeses and hotdogs. After IMS capture, bacteria were released from the beads, used in the fiber optic assay or plated on agar for counting. In parallel, the capture of L. monocytogenes was confirmed by real-time qPCR and light-scattering technology (BARDOT). Using IMS to concentrate and separate L. monocytogenes, followed by a fiber optic platform, it was possible to detect in less than 22 h, approximately 40 CFU/g of L. monocytogenesi, even in the presence of L. innocua in cheese and hot dogs artificially contaminated. In addition, using mass spectrometry (MALDI-TOF-MS) the protein to which MAb-3F8 binds, was identified as fructose 1,6-bisphosphate aldolase (FBA). The results presented in this work indicate that using both systems together, the IMS and fiber optic immunosensor, were more reliable and faster, and could be applied in the routinely for detection of L. monocytogenes in food. Moreover, both MAbs have the potential to useful in others biosensor platforms, as well as in other detection and functionality immunoassays for InlA and FBA in Listeria.
dirty 0
eu_rights_str_mv openAccess
format doctoralThesis
id oasisbr_0ee1975a8c4f245feae3a7e15a4511ce
identifier.url.fl_str_mv http://repositorio.ufpel.edu.br/handle/ri/1299
inst_facet_str urn:organizationAcronym:oasisbr{{{_:::_}}}IBICT
instacron_str OASISBR
institution IBICT
instname_str IBICT
language por
network_acronym_str oasisbr
network_name_str Oasisbr
oai_identifier_str oai:guaiaca.ufpel.edu.br:123456789/1299
organization_str_mv urn:organizationAcronym:oasisbr
person_str_mv Mendonça, Marcelo
publishDate 2014
publisher.none.fl_str_mv Universidade Federal de Pelotas
Programa de Pós-Graduação em Biotecnologia
UFPel
BR
Biotecnologia
repo_facet_str urn:repositoryAcronym:oasisbr{{{_:::_}}}Oasisbr
reponame_str Oasisbr
repository_id_str urn:repositoryAcronym:oasisbr
service_str_mv urn:repositoryAcronym:oasisbr
spelling Anticorpos Monoclonais contra Listeria spp.: Produção, Caracterização e Aplicação em Métodos DiagnósticosMonoclonal Antibodies againstListeria spp.: Production, Characterization and Application in Diagnostic MethodsMendonça, MarceloL. monocytogenesInternalina AAnticorpos monoclonaisImunoseparação magnéticaSensor de fibra óticaL. monocytogenesInternalin AMonoclonal antibodyImmunomagnetic separationFiber optic sensorCNPQ::CIENCIAS BIOLOGICAS::IMUNOLOGIAopen accesshttp://purl.org/coar/access_right/c_abf2http://repositorio.ufpel.edu.br/handle/ri/1299URLMENDONÇA, Marcelo. Monoclonal Antibodies againstListeria spp.: Production, Characterization and Application in Diagnostic Methods. 2011. 109 f. Tese (Doutorado em Biotecnologia) - Universidade Federal de Pelotas, Pelotas, 2011.N/AHasVersionhttp://repositorio.ufpel.edu.br/handle/ri/1299URLHasVersion2014-08-20T13:33:00Z2011-12-012014-08-202012-04-26T00:00:00ZThe conventional methods used to detect the Listeria monocytogenes in foods are laborious and expensive, requiring several days for final identification. Monoclonal antibody (MAb) based immunoassays are highly specific and rapid to perform, especially when MAbs are raised to conserved virulence factors in the pathogen. Among diverse virulence factors of L. monocytogenes, the surface protein internalin A (InlA) is one of the most well-known and characterized protein, being an excellent target as it is highly exposed on the surface and exclusive of pathogenic species. In this work we report the production, characterization and use of a panel of MAbs against InlA (2D12, 3B7, 4E4), and a MAb (3F8) which specifically recognizes all bacteria belonging the genus Listeria. MAbs were produced by the immunization of BALB/c mice with a recombinant InlA together with heat killed L. monocytogenes. The MAbs produced showed excellent reativities by indirect ELISA, Western blot and immunofluorescence. A Cy5 conjugated anti-InlA MAb-2D12 was used as detection antibody for L. monocytogenes in a sandwich-like fiber optic immunoassay. Using MAb-2D12 as capture antibody on the waveguides, the limit of detection was ~3 x 102 CFU.mL-1, and when MAb-3F8 was used for capture the limit of detection was ~1 x 105 CFU.mL-1. Furthermore, MAbs 2D12 and 3F8 were used to coat paramagnetic beads and tested in the immunomagnetic separation (IMS) of L. monocytogenes from pure cultures, and artificially contaminated cheeses and hotdogs. After IMS capture, bacteria were released from the beads, used in the fiber optic assay or plated on agar for counting. In parallel, the capture of L. monocytogenes was confirmed by real-time qPCR and light-scattering technology (BARDOT). Using IMS to concentrate and separate L. monocytogenes, followed by a fiber optic platform, it was possible to detect in less than 22 h, approximately 40 CFU/g of L. monocytogenesi, even in the presence of L. innocua in cheese and hot dogs artificially contaminated. In addition, using mass spectrometry (MALDI-TOF-MS) the protein to which MAb-3F8 binds, was identified as fructose 1,6-bisphosphate aldolase (FBA). The results presented in this work indicate that using both systems together, the IMS and fiber optic immunosensor, were more reliable and faster, and could be applied in the routinely for detection of L. monocytogenes in food. Moreover, both MAbs have the potential to useful in others biosensor platforms, as well as in other detection and functionality immunoassays for InlA and FBA in Listeria.Os métodos convencionais empregados para detecção de Listeria monocytogenes em alimentos são laboriosos e onerosos, requerendo vários dias para sua identificação final. A utilização de anticorpos monoclonais (MAbs) em imunoensaios para detecção rápida de bactérias tem como vantagem a alta especificidade e rapidez, principalmente quando direcionados para fatores de virulência conservados. Dentre os diversos fatores de virulência de Listeria, a proteína de membrana internalina A (InlA), é umas das mais bem caracterizadas, sendo um excelente alvo por ser altamente exposta na superfície e exclusiva de espécies patogênicas. Neste trabalho é relatado a produção, caracterização e utilização em métodos de diagnósticos de um painel de MAbs contra a InlA (2D12, 3B7, 4E4), e de um MAb (3F8) que reconhece especificamente todas as bactérias do gênero Listeria. Na produção dos MAbs, camundongos BALB/c foram imunizados com uma proteína recombinante InlA (rInlA) concomitantemente com L. monocytogenes inativadas por fervura. Os MAbs gerados demonstraram excelente reatividade por ELISA indireto, Western blot e imunofluorescência. O MAb anti-InlA 2D12 marcado com Cy5 foi usado como anticorpo de detecção de L. monocytogenes, no sistema tipo sanduíche de sensor de fibra óptica. Usando MAb-2D12 como anticorpo de captura nas fibras ópticas, obteve-se um limite de detecção de ~3 x 102 CFU.mL-1, e um limite de detecção de ~1 x 105 CFU.mL-1 foi visualizado com MAb-3F8 como captura. Os MAbs anti-InlA 2D12 e anti-Listeria 3F8 foram posteriormente utilizados para sensibilizar esferas paramagnéticas e testados na separação imunomagnética (IMS) de L. monocytogenes em culturas puras, e em queijo e salsichas tipo hotdog artificialmente contaminados. Após a captura por IMS, as bactérias foram liberadas, incubadas com a fibra óptica ou plaqueadas em agares para contagem. Em paralelo, a confirmação da captura de L. monocytogenes foi realizada por PCR quantitativo em tempo real e por light-scattering technology (BARDOT). Utilizando IMS para separar e concentrar L. monocytogenes, seguido da utilização em plataforma de fibra óptica, foi possível realizar a detecção em menos de 22 horas, de aproximadamente 40 UFC/g de L. monocytogenes em presença de L. innocua, em queijo e salsicha artificialmente contaminados. Além disso, a proteína alvo do MAb3F8 foi identificado como frutose 1,6-bifosfato aldolase através de espectrometria de massa (MALDI-TOF-MS). Os resultados obtidos nesse trabalho indicam que a utilização em conjunto dos sistemas de IMS e fibra óptica com os MAb-2D12 e MAb3F8, foram confiáveis e rápidos, e assim, podendo ser empregados em imunoensaios de rotina para detecção de L. monocytogenes em alimentos. Contudo, ambos MAbs possuem ainda grande potencial para serem mais explorados em outras plataformas de biossensores, assim como, em outros imunoensaios de detecção e funcionalidade de InlA e FBA em Listeriaporapplication/pdfUniversidade Federal de PelotasPrograma de Pós-Graduação em BiotecnologiaUFPelBRBiotecnologiareponame:Repositório Institucional da UFPel - Guaiacainstname:Universidade Federal de Pelotas (UFPEL)instacron:UFPELVoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85doctoral thesishttp://purl.org/coar/resource_type/c_db06other research product
spellingShingle Anticorpos Monoclonais contra Listeria spp.: Produção, Caracterização e Aplicação em Métodos Diagnósticos
Mendonça, Marcelo
L. monocytogenes
Internalina A
Anticorpos monoclonais
Imunoseparação magnética
Sensor de fibra ótica
L. monocytogenes
Internalin A
Monoclonal antibody
Immunomagnetic separation
Fiber optic sensor
CNPQ::CIENCIAS BIOLOGICAS::IMUNOLOGIA
status SINGLETON
status_str VoR
subject.fl_str_mv L. monocytogenes
Internalina A
Anticorpos monoclonais
Imunoseparação magnética
Sensor de fibra ótica
L. monocytogenes
Internalin A
Monoclonal antibody
Immunomagnetic separation
Fiber optic sensor
CNPQ::CIENCIAS BIOLOGICAS::IMUNOLOGIA
title Anticorpos Monoclonais contra Listeria spp.: Produção, Caracterização e Aplicação em Métodos Diagnósticos
title_full Anticorpos Monoclonais contra Listeria spp.: Produção, Caracterização e Aplicação em Métodos Diagnósticos
title_fullStr Anticorpos Monoclonais contra Listeria spp.: Produção, Caracterização e Aplicação em Métodos Diagnósticos
title_full_unstemmed Anticorpos Monoclonais contra Listeria spp.: Produção, Caracterização e Aplicação em Métodos Diagnósticos
title_short Anticorpos Monoclonais contra Listeria spp.: Produção, Caracterização e Aplicação em Métodos Diagnósticos
title_sort Anticorpos Monoclonais contra Listeria spp.: Produção, Caracterização e Aplicação em Métodos Diagnósticos
topic L. monocytogenes
Internalina A
Anticorpos monoclonais
Imunoseparação magnética
Sensor de fibra ótica
L. monocytogenes
Internalin A
Monoclonal antibody
Immunomagnetic separation
Fiber optic sensor
CNPQ::CIENCIAS BIOLOGICAS::IMUNOLOGIA
topic_facet L. monocytogenes
Internalina A
Anticorpos monoclonais
Imunoseparação magnética
Sensor de fibra ótica
L. monocytogenes
Internalin A
Monoclonal antibody
Immunomagnetic separation
Fiber optic sensor
CNPQ::CIENCIAS BIOLOGICAS::IMUNOLOGIA
url http://repositorio.ufpel.edu.br/handle/ri/1299
visible 1

Funded activities

No funded projects found.