Resumo:Diabetes Mellitus (DM) is a chronic metabolic disease characterized by high blood glucose levels and classified into different types, including DM1 and DM2. It is currently facing an increasing global prevalence and is considered an “epidemic”; that requires appropriate control and prevention measures. Monitoring glucose levels plays a crucial role in the effective management of diabetes, allowing personalized treatment and detection of rapid changes in its plasma concentration.The remarkable development of glucose biosensors now provides a simple, fast and cost-effective solution for self-monitoring of glucose levels by diabetic patients. Electrochemical biosensors offer several advantages over other types, which has led to significant investment in their improvement and optimization of analytical performance.Continuous glucose monitoring (CGM) has demonstrated advantages over traditional self-monitoring (SMBG) in glycemic control in patients with DM1 or DM2. Insulin pumps and hybrid devices have improved glycemic control, improving quality of life and reducing the need for continuous glucose monitoring. In addition, artificial intelligence and big data play an essential role in analysis and decision-making in diabetes care, which requires careful attention to ethical and personal data protection.Despite significant advances in diabetes monitoring, the future lies in non-invasive approaches, including the development of wearable biosensors and the exploration of other biological fluids for glucose determination, to minimize the impact of invasive approaches on the quality of life of diabetic patients.
Autores principais:Alves, Pedro Alexandre Gomes
Assunto:Diabetes Mellitus Epidemic Biosensors Traditional self-monitoring Continuous monitoring Diabetes Mellitus Epidemia Biossensores Auto-monitorização tradicional Monitorização contínua
Ano:2023
País:Portugal
Tipo de documento:dissertação de mestrado
Tipo de acesso:acesso aberto
Instituição associada:Universidade de Coimbra
Idioma:português
Origem:Estudo Geral - Universidade de Coimbra
_version_ 1877781044139130880
author Alves, Pedro Alexandre Gomes
author_facet Alves, Pedro Alexandre Gomes
author_role author
contributor_name_str_mv Ribeiro, Daniel Alves
Reis, Maria Adelaide Rodrigues
Barbosa, Rui Manuel Silva Gomes
Estudo Geral
country_str PT
creators_json_txt [{\"Person.name\":\"Alves, Pedro Alexandre Gomes\"}]
datacite.contributors.contributor.contributorName.fl_str_mv Ribeiro, Daniel Alves
Reis, Maria Adelaide Rodrigues
Barbosa, Rui Manuel Silva Gomes
Estudo Geral
datacite.creators.creator.creatorName.fl_str_mv Alves, Pedro Alexandre Gomes
datacite.date.Accepted.fl_str_mv 2023-10-09T00:00:00Z
datacite.rights.fl_str_mv http://purl.org/coar/access_right/c_abf2
datacite.subjects.subject.fl_str_mv Diabetes Mellitus
Epidemic
Biosensors
Traditional self-monitoring
Continuous monitoring
Diabetes Mellitus
Epidemia
Biossensores
Auto-monitorização tradicional
Monitorização contínua
datacite.titles.title.fl_str_mv O Biossensor Eletroquímico da Glicose na Diabetes Mellitus: do Auto-Teste à Monitorização Contínua
The Electrochemical Glucose Biosensor in Diabetes Mellitus: from Self-Testing to Continuous Monitoring
dc.contributor.none.fl_str_mv Ribeiro, Daniel Alves
Reis, Maria Adelaide Rodrigues
Barbosa, Rui Manuel Silva Gomes
Estudo Geral
dc.creator.none.fl_str_mv Alves, Pedro Alexandre Gomes
dc.date.Accepted.fl_str_mv 2023-10-09T00:00:00Z
dc.description.none.fl_str_mv A Diabetes Mellitus (DM) é uma doença metabólica crónica caracterizada por níveis elevados de glicose no sangue e classificada em diferentes tipos, incluindo DM1 e DM2. Atualmente, enfrenta uma prevalência global crescente, sendo considerada uma “epidemia”, que exige medidas de controlo e prevenção adequadas. A monitorização dos níveis de glicose desempenha um papel crucial no controlo eficaz da diabetes, permitindo um tratamento personalizado e a deteção de alterações rápidas da sua concentração plasmática.O notável desenvolvimento dos biossensores de glicose, proporciona hoje uma solução simples, rápida e económica de auto-monitorização dos níveis glicose pelos doentes diabéticos. Os biossensores eletroquímicos oferecem várias vantagens em relação a outros tipos, o que tem levando a um investimento significativo no seu aperfeiçoamento, e na otimização do seu desempenho analítico.A monitorização contínua da glicose (MCG) tem demonstrado vantagens sobre a auto- monitorização tradicional (SMBG) no controlo glicémico em doentes com DM1 ou DM2. As bombas de insulina e os dispositivos híbridos melhoraram o controlo glicémico, melhorando a qualidade de vida e reduzindo a necessidade de monitorização contínua da glicose. Além disso, a inteligência artificial e os Big Data desempenham um papel essencial na análise e na tomada de decisões nos cuidados da diabetes, o que exige uma atenção cuidadosa à proteção ética e dos dados pessoais.Apesar dos avanços significativos na monitorização da diabetes, o futuro reside em abordagens não invasivas, incluindo o desenvolvimento de biossensores vestíveis e a exploração de outros fluidos biológicos para a determinação da glicose, a fim de minimizar o impacto das abordagens invasivas na qualidade de vida dos doentes diabéticos.
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv https://hdl.handle.net/10316/112862
dc.language.none.fl_str_mv por
dc.rights.none.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.subject.none.fl_str_mv Diabetes Mellitus
Epidemic
Biosensors
Traditional self-monitoring
Continuous monitoring
Diabetes Mellitus
Epidemia
Biossensores
Auto-monitorização tradicional
Monitorização contínua
dc.title.fl_str_mv O Biossensor Eletroquímico da Glicose na Diabetes Mellitus: do Auto-Teste à Monitorização Contínua
The Electrochemical Glucose Biosensor in Diabetes Mellitus: from Self-Testing to Continuous Monitoring
dc.type.none.fl_str_mv http://purl.org/coar/resource_type/c_bdcc
description Diabetes Mellitus (DM) is a chronic metabolic disease characterized by high blood glucose levels and classified into different types, including DM1 and DM2. It is currently facing an increasing global prevalence and is considered an “epidemic”; that requires appropriate control and prevention measures. Monitoring glucose levels plays a crucial role in the effective management of diabetes, allowing personalized treatment and detection of rapid changes in its plasma concentration.The remarkable development of glucose biosensors now provides a simple, fast and cost-effective solution for self-monitoring of glucose levels by diabetic patients. Electrochemical biosensors offer several advantages over other types, which has led to significant investment in their improvement and optimization of analytical performance.Continuous glucose monitoring (CGM) has demonstrated advantages over traditional self-monitoring (SMBG) in glycemic control in patients with DM1 or DM2. Insulin pumps and hybrid devices have improved glycemic control, improving quality of life and reducing the need for continuous glucose monitoring. In addition, artificial intelligence and big data play an essential role in analysis and decision-making in diabetes care, which requires careful attention to ethical and personal data protection.Despite significant advances in diabetes monitoring, the future lies in non-invasive approaches, including the development of wearable biosensors and the exploration of other biological fluids for glucose determination, to minimize the impact of invasive approaches on the quality of life of diabetic patients.
dirty 0
eu_rights_str_mv openAccess
format masterThesis
id estudogl_c10aee862caee26f01b5ad32f933fb2f
identifier.url.fl_str_mv https://hdl.handle.net/10316/112862
inst_facet_str urn:organizationAcronym:uc{{{_:::_}}}Universidade de Coimbra
instacron_str uc
institution Universidade de Coimbra
instname_str Universidade de Coimbra
language por
network_acronym_str estudogl
network_name_str Estudo Geral - Universidade de Coimbra
oai_identifier_str oai:estudogeral.uc.pt:10316/112862
organization_str_mv urn:organizationAcronym:uc
person_str_mv Alves, Pedro Alexandre Gomes
publishDate 2023
repo_facet_str urn:repositoryAcronym:estudogl{{{_:::_}}}Estudo Geral - Universidade de Coimbra
reponame_str Estudo Geral - Universidade de Coimbra
repository_id_str urn:repositoryAcronym:estudogl
service_str_mv urn:repositoryAcronym:estudogl
spelling porengDiabetes Mellitus (DM) is a chronic metabolic disease characterized by high blood glucose levels and classified into different types, including DM1 and DM2. It is currently facing an increasing global prevalence and is considered an “epidemic”; that requires appropriate control and prevention measures. Monitoring glucose levels plays a crucial role in the effective management of diabetes, allowing personalized treatment and detection of rapid changes in its plasma concentration.The remarkable development of glucose biosensors now provides a simple, fast and cost-effective solution for self-monitoring of glucose levels by diabetic patients. Electrochemical biosensors offer several advantages over other types, which has led to significant investment in their improvement and optimization of analytical performance.Continuous glucose monitoring (CGM) has demonstrated advantages over traditional self-monitoring (SMBG) in glycemic control in patients with DM1 or DM2. Insulin pumps and hybrid devices have improved glycemic control, improving quality of life and reducing the need for continuous glucose monitoring. In addition, artificial intelligence and big data play an essential role in analysis and decision-making in diabetes care, which requires careful attention to ethical and personal data protection.Despite significant advances in diabetes monitoring, the future lies in non-invasive approaches, including the development of wearable biosensors and the exploration of other biological fluids for glucose determination, to minimize the impact of invasive approaches on the quality of life of diabetic patients.porA Diabetes Mellitus (DM) é uma doença metabólica crónica caracterizada por níveis elevados de glicose no sangue e classificada em diferentes tipos, incluindo DM1 e DM2. Atualmente, enfrenta uma prevalência global crescente, sendo considerada uma “epidemia”, que exige medidas de controlo e prevenção adequadas. A monitorização dos níveis de glicose desempenha um papel crucial no controlo eficaz da diabetes, permitindo um tratamento personalizado e a deteção de alterações rápidas da sua concentração plasmática.O notável desenvolvimento dos biossensores de glicose, proporciona hoje uma solução simples, rápida e económica de auto-monitorização dos níveis glicose pelos doentes diabéticos. Os biossensores eletroquímicos oferecem várias vantagens em relação a outros tipos, o que tem levando a um investimento significativo no seu aperfeiçoamento, e na otimização do seu desempenho analítico.A monitorização contínua da glicose (MCG) tem demonstrado vantagens sobre a auto- monitorização tradicional (SMBG) no controlo glicémico em doentes com DM1 ou DM2. As bombas de insulina e os dispositivos híbridos melhoraram o controlo glicémico, melhorando a qualidade de vida e reduzindo a necessidade de monitorização contínua da glicose. Além disso, a inteligência artificial e os Big Data desempenham um papel essencial na análise e na tomada de decisões nos cuidados da diabetes, o que exige uma atenção cuidadosa à proteção ética e dos dados pessoais.Apesar dos avanços significativos na monitorização da diabetes, o futuro reside em abordagens não invasivas, incluindo o desenvolvimento de biossensores vestíveis e a exploração de outros fluidos biológicos para a determinação da glicose, a fim de minimizar o impacto das abordagens invasivas na qualidade de vida dos doentes diabéticos.application/pdfporO Biossensor Eletroquímico da Glicose na Diabetes Mellitus: do Auto-Teste à Monitorização ContínuaAlternativeTitleengThe Electrochemical Glucose Biosensor in Diabetes Mellitus: from Self-Testing to Continuous MonitoringAlves, Pedro Alexandre GomesRibeiro, Daniel AlvesReis, Maria Adelaide RodriguesBarbosa, Rui Manuel Silva GomesHostingInstitutionOrganizationalEstudo Gerale-mailmailto:inf@sib.uc.ptinf@sib.uc.pt2023-10-092023-10-09T00:00:00ZHandlehttps://hdl.handle.net/10316/112862http://purl.org/coar/access_right/c_abf2open accessDiabetes MellitusEpidemicBiosensorsTraditional self-monitoringContinuous monitoringDiabetes MellitusEpidemiaBiossensoresAuto-monitorização tradicionalMonitorização contínua8178179 bytesliteraturehttp://purl.org/coar/resource_type/c_bdccmaster thesisapplication/pdfhttps://estudogeral.uc.pt/bitstream/10316/112862/-1/Documento%20%c3%9anico%20Pedro%20Alves%202018281791.pdf
spellingShingle O Biossensor Eletroquímico da Glicose na Diabetes Mellitus: do Auto-Teste à Monitorização Contínua
Alves, Pedro Alexandre Gomes
Diabetes Mellitus
Epidemic
Biosensors
Traditional self-monitoring
Continuous monitoring
Diabetes Mellitus
Epidemia
Biossensores
Auto-monitorização tradicional
Monitorização contínua
status SINGLETON
subject.fl_str_mv Diabetes Mellitus
Epidemic
Biosensors
Traditional self-monitoring
Continuous monitoring
Diabetes Mellitus
Epidemia
Biossensores
Auto-monitorização tradicional
Monitorização contínua
title O Biossensor Eletroquímico da Glicose na Diabetes Mellitus: do Auto-Teste à Monitorização Contínua
title_full O Biossensor Eletroquímico da Glicose na Diabetes Mellitus: do Auto-Teste à Monitorização Contínua
title_fullStr O Biossensor Eletroquímico da Glicose na Diabetes Mellitus: do Auto-Teste à Monitorização Contínua
title_full_unstemmed O Biossensor Eletroquímico da Glicose na Diabetes Mellitus: do Auto-Teste à Monitorização Contínua
title_short O Biossensor Eletroquímico da Glicose na Diabetes Mellitus: do Auto-Teste à Monitorização Contínua
title_sort O Biossensor Eletroquímico da Glicose na Diabetes Mellitus: do Auto-Teste à Monitorização Contínua
topic Diabetes Mellitus
Epidemic
Biosensors
Traditional self-monitoring
Continuous monitoring
Diabetes Mellitus
Epidemia
Biossensores
Auto-monitorização tradicional
Monitorização contínua
topic_facet Diabetes Mellitus
Epidemic
Biosensors
Traditional self-monitoring
Continuous monitoring
Diabetes Mellitus
Epidemia
Biossensores
Auto-monitorização tradicional
Monitorização contínua
url https://hdl.handle.net/10316/112862
visible 1

Atividades financiadas

Não foram encontrados projetos financiados.