Publicação

Surface modification of an intraocular lens material by plasma-assisted grafting with 2- hydroxyethyl methacrylate (HEMA), for controlled release of moxifloxacin

Ver documento

Detalhes bibliográficos
Resumo:Endophthalmitis, an inflammation of the eye due to perioperative infection, may occur after cataract surgery. Intraocular lenses (IOLs) loaded with an antibiotic have been proposed as an alternative to the conventional postoperative endophthalmitis prophylaxis, since the antibiotic is delivered directly to the target site. In this work, an IOL-based antibiotic releasing system was prepared from a copolymer used in the production of IOLs and a fluoroquinolone used in endophthalmitis prophylaxis (moxifloxacin, MFX). Argon plasma-assisted grafting with 2- hydroxyethyl methacrylate (HEMA) in the presence of MFX was the approach selected for surface modification, with MFX loaded both by entrapment in the grafted polyHEMA coating and by soaking. Surface and bulk properties were evaluated before and after surface modification and the MFX release profiles were obtained both in batch mode (sink conditions) and under hydrodynamic conditions, employing a purpose-built microfluidic cell, which simulated the hydrodynamic conditions around the eye lens. The effect of storage on the release profile of the best system was also assessed. The best system released MFX for ca. 15 days above the minimum inhibitory concentration for Staphylococcus aureus and Staphylococcus epidermidis. The released MFX showed antimicrobial activity against these bacteria and was non-cytotoxic against corneal endothelial cells.
Autores principais:Vieira, A. Paula
Outros Autores:Pimenta, Andreia F. R.; Silva, Diana; Gil, M. Helena; Alves, Patrícia; Coimbra, Patrícia; Mata, José L. G. C.; Bozukova, Dimitriya; Correia, Tiago R.; Correia, Ilídio J.; Serro, A. Paula; Guiomar, A. Jorge
Assunto:Cataract; endophthalmitis; intraocular lens; controlled release; moxifloxacin; plasma grafting; argon; 2- hydroxyethyl methacrylate
Ano:2017
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:Universidade de Coimbra
Idioma:inglês
Origem:Estudo Geral - Universidade de Coimbra
_version_ 1877780018162040832
author Vieira, A. Paula
author2 Pimenta, Andreia F. R.
Silva, Diana
Gil, M. Helena
Alves, Patrícia
Coimbra, Patrícia
Mata, José L. G. C.
Bozukova, Dimitriya
Correia, Tiago R.
Correia, Ilídio J.
Serro, A. Paula
Guiomar, A. Jorge
author2_role author
author
author
author
author
author
author
author
author
author
author
author_facet Vieira, A. Paula
Pimenta, Andreia F. R.
Silva, Diana
Gil, M. Helena
Alves, Patrícia
Coimbra, Patrícia
Mata, José L. G. C.
Bozukova, Dimitriya
Correia, Tiago R.
Correia, Ilídio J.
Serro, A. Paula
Guiomar, A. Jorge
author_role author
contributor_name_str_mv Estudo Geral
country_str PT
creators_json_txt [{\"Person.name\":\"Vieira, A. Paula\"},{\"Person.name\":\"Pimenta, Andreia F. R.\"},{\"Person.name\":\"Silva, Diana\"},{\"Person.name\":\"Gil, M. Helena\"},{\"Person.name\":\"Alves, Patrícia\"},{\"Person.name\":\"Coimbra, Patrícia\"},{\"Person.name\":\"Mata, José L. G. C.\"},{\"Person.name\":\"Bozukova, Dimitriya\"},{\"Person.name\":\"Correia, Tiago R.\"},{\"Person.name\":\"Correia, Ilídio J.\"},{\"Person.name\":\"Serro, A. Paula\"},{\"Person.name\":\"Guiomar, A. Jorge\"}]
datacite.contributors.contributor.contributorName.fl_str_mv Estudo Geral
datacite.creators.creator.creatorName.fl_str_mv Vieira, A. Paula
Pimenta, Andreia F. R.
Silva, Diana
Gil, M. Helena
Alves, Patrícia
Coimbra, Patrícia
Mata, José L. G. C.
Bozukova, Dimitriya
Correia, Tiago R.
Correia, Ilídio J.
Serro, A. Paula
Guiomar, A. Jorge
datacite.date.Accepted.fl_str_mv 2017-08-16T00:00:00Z
datacite.rights.fl_str_mv http://purl.org/coar/access_right/c_abf2
datacite.subjects.subject.fl_str_mv Cataract; endophthalmitis; intraocular lens; controlled release; moxifloxacin; plasma grafting; argon; 2- hydroxyethyl methacrylate
datacite.titles.title.fl_str_mv Surface modification of an intraocular lens material by plasma-assisted grafting with 2- hydroxyethyl methacrylate (HEMA), for controlled release of moxifloxacin
dc.contributor.none.fl_str_mv Estudo Geral
dc.creator.none.fl_str_mv Vieira, A. Paula
Pimenta, Andreia F. R.
Silva, Diana
Gil, M. Helena
Alves, Patrícia
Coimbra, Patrícia
Mata, José L. G. C.
Bozukova, Dimitriya
Correia, Tiago R.
Correia, Ilídio J.
Serro, A. Paula
Guiomar, A. Jorge
dc.date.Accepted.fl_str_mv 2017-08-16T00:00:00Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv https://hdl.handle.net/10316/44169
dc.language.none.fl_str_mv eng
dc.publisher.none.fl_str_mv Elsevier
dc.rights.none.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.subject.none.fl_str_mv Cataract; endophthalmitis; intraocular lens; controlled release; moxifloxacin; plasma grafting; argon; 2- hydroxyethyl methacrylate
dc.title.fl_str_mv Surface modification of an intraocular lens material by plasma-assisted grafting with 2- hydroxyethyl methacrylate (HEMA), for controlled release of moxifloxacin
dc.type.none.fl_str_mv http://purl.org/coar/resource_type/c_6501
description Endophthalmitis, an inflammation of the eye due to perioperative infection, may occur after cataract surgery. Intraocular lenses (IOLs) loaded with an antibiotic have been proposed as an alternative to the conventional postoperative endophthalmitis prophylaxis, since the antibiotic is delivered directly to the target site. In this work, an IOL-based antibiotic releasing system was prepared from a copolymer used in the production of IOLs and a fluoroquinolone used in endophthalmitis prophylaxis (moxifloxacin, MFX). Argon plasma-assisted grafting with 2- hydroxyethyl methacrylate (HEMA) in the presence of MFX was the approach selected for surface modification, with MFX loaded both by entrapment in the grafted polyHEMA coating and by soaking. Surface and bulk properties were evaluated before and after surface modification and the MFX release profiles were obtained both in batch mode (sink conditions) and under hydrodynamic conditions, employing a purpose-built microfluidic cell, which simulated the hydrodynamic conditions around the eye lens. The effect of storage on the release profile of the best system was also assessed. The best system released MFX for ca. 15 days above the minimum inhibitory concentration for Staphylococcus aureus and Staphylococcus epidermidis. The released MFX showed antimicrobial activity against these bacteria and was non-cytotoxic against corneal endothelial cells.
dirty 0
eu_rights_str_mv openAccess
format article
id estudogl_5338c0185d4d7b3946fd25272f940801
identifier.url.fl_str_mv https://hdl.handle.net/10316/44169
inst_facet_str urn:organizationAcronym:uc{{{_:::_}}}Universidade de Coimbra
instacron_str uc
institution Universidade de Coimbra
instname_str Universidade de Coimbra
language eng
network_acronym_str estudogl
network_name_str Estudo Geral - Universidade de Coimbra
oai_identifier_str oai:estudogeral.uc.pt:10316/44169
organization_str_mv urn:organizationAcronym:uc
person_str_mv Vieira, A. Paula
Pimenta, Andreia F. R.
Silva, Diana
Gil, M. Helena
Alves, Patrícia
Coimbra, Patrícia
Mata, José L. G. C.
Bozukova, Dimitriya
Correia, Tiago R.
Correia, Ilídio J.
Serro, A. Paula
Guiomar, A. Jorge
publishDate 2017
publisher.none.fl_str_mv Elsevier
repo_facet_str urn:repositoryAcronym:estudogl{{{_:::_}}}Estudo Geral - Universidade de Coimbra
reponame_str Estudo Geral - Universidade de Coimbra
repository_id_str urn:repositoryAcronym:estudogl
service_str_mv urn:repositoryAcronym:estudogl
spelling engElsevierengEndophthalmitis, an inflammation of the eye due to perioperative infection, may occur after cataract surgery. Intraocular lenses (IOLs) loaded with an antibiotic have been proposed as an alternative to the conventional postoperative endophthalmitis prophylaxis, since the antibiotic is delivered directly to the target site. In this work, an IOL-based antibiotic releasing system was prepared from a copolymer used in the production of IOLs and a fluoroquinolone used in endophthalmitis prophylaxis (moxifloxacin, MFX). Argon plasma-assisted grafting with 2- hydroxyethyl methacrylate (HEMA) in the presence of MFX was the approach selected for surface modification, with MFX loaded both by entrapment in the grafted polyHEMA coating and by soaking. Surface and bulk properties were evaluated before and after surface modification and the MFX release profiles were obtained both in batch mode (sink conditions) and under hydrodynamic conditions, employing a purpose-built microfluidic cell, which simulated the hydrodynamic conditions around the eye lens. The effect of storage on the release profile of the best system was also assessed. The best system released MFX for ca. 15 days above the minimum inhibitory concentration for Staphylococcus aureus and Staphylococcus epidermidis. The released MFX showed antimicrobial activity against these bacteria and was non-cytotoxic against corneal endothelial cells.application/pdfporSurface modification of an intraocular lens material by plasma-assisted grafting with 2- hydroxyethyl methacrylate (HEMA), for controlled release of moxifloxacinVieira, A. PaulaPimenta, Andreia F. R.Silva, DianaGil, M. HelenaAlves, PatríciaCoimbra, PatríciaMata, José L. G. C.Bozukova, DimitriyaCorreia, Tiago R.Correia, Ilídio J.Serro, A. PaulaGuiomar, A. JorgeHostingInstitutionOrganizationalEstudo Gerale-mailmailto:inf@sib.uc.ptinf@sib.uc.ptDOIIsPartOf10.1016/j.ejpb.2017.08.0062017-08-162017-08-16T00:00:00ZHandlehttps://hdl.handle.net/10316/44169http://purl.org/coar/access_right/c_abf2open accessCataract; endophthalmitis; intraocular lens; controlled release; moxifloxacin; plasma grafting; argon; 2- hydroxyethyl methacrylate1176379 bytesliteraturehttp://purl.org/coar/resource_type/c_6501journal articleapplication/pdfhttps://estudogeral.uc.pt/bitstream/10316/44169/1/AcceptedManuscript_IOLsPlasmaHEMA_MFX_EurJPharmBiopharm_120_52_2017.pdf
spellingShingle Surface modification of an intraocular lens material by plasma-assisted grafting with 2- hydroxyethyl methacrylate (HEMA), for controlled release of moxifloxacin
Vieira, A. Paula
Cataract; endophthalmitis; intraocular lens; controlled release; moxifloxacin; plasma grafting; argon; 2- hydroxyethyl methacrylate
status SINGLETON
subject.fl_str_mv Cataract; endophthalmitis; intraocular lens; controlled release; moxifloxacin; plasma grafting; argon; 2- hydroxyethyl methacrylate
title Surface modification of an intraocular lens material by plasma-assisted grafting with 2- hydroxyethyl methacrylate (HEMA), for controlled release of moxifloxacin
title_full Surface modification of an intraocular lens material by plasma-assisted grafting with 2- hydroxyethyl methacrylate (HEMA), for controlled release of moxifloxacin
title_fullStr Surface modification of an intraocular lens material by plasma-assisted grafting with 2- hydroxyethyl methacrylate (HEMA), for controlled release of moxifloxacin
title_full_unstemmed Surface modification of an intraocular lens material by plasma-assisted grafting with 2- hydroxyethyl methacrylate (HEMA), for controlled release of moxifloxacin
title_short Surface modification of an intraocular lens material by plasma-assisted grafting with 2- hydroxyethyl methacrylate (HEMA), for controlled release of moxifloxacin
title_sort Surface modification of an intraocular lens material by plasma-assisted grafting with 2- hydroxyethyl methacrylate (HEMA), for controlled release of moxifloxacin
topic Cataract; endophthalmitis; intraocular lens; controlled release; moxifloxacin; plasma grafting; argon; 2- hydroxyethyl methacrylate
topic_facet Cataract; endophthalmitis; intraocular lens; controlled release; moxifloxacin; plasma grafting; argon; 2- hydroxyethyl methacrylate
url https://hdl.handle.net/10316/44169
visible 1

Atividades financiadas

Não foram encontrados projetos financiados.