Resumo:Batch injection analysis (BIA) enables the investigation of electrode reactions using extremely small volumes of analyte solution of 100 pL. The potentialities of amperometric and voltammetric detection have been examined by studying the oxidation of ferrocyanide and ascorbic acid at platinum electrodes and using sample volumes between 10 and 100 pL. The electrolysis efficiency as a function of injected volume has been addressed. Consecutive injections during a slow linear potential sweep permit the registering of a point-by-point pseudo-steady-state voltammetric curve and allow the measurement of thermodynamic and kinetic parameters as well as the determination of concentration. Cyclic voltammetry during or after injection can aid in mechanistic studies. The combination of BIA and square-wave voltammetry leads to a continuous voltammetric profile from a single injection using 100 p L calibration plots show a factor of 4 sensitivity increase relative to fixed-potential amperometric detection.
Autores principais:Brett, Christopher M. A.
Outros Autores:Brett, Ana Maria Oliveira; Mitoseriu, Lucian Costel
Ano:1994
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:Universidade de Coimbra
Idioma:inglês
Origem:Estudo Geral - Universidade de Coimbra
_version_ 1877780171212193792
author Brett, Christopher M. A.
author2 Brett, Ana Maria Oliveira
Mitoseriu, Lucian Costel
author2_role author
author
author_facet Brett, Christopher M. A.
Brett, Ana Maria Oliveira
Mitoseriu, Lucian Costel
author_role author
contributor_name_str_mv Estudo Geral
country_str PT
creators_json_txt [{\"Person.name\":\"Brett, Christopher M. A.\"},{\"Person.name\":\"Brett, Ana Maria Oliveira\"},{\"Person.name\":\"Mitoseriu, Lucian Costel\"}]
datacite.contributors.contributor.contributorName.fl_str_mv Estudo Geral
datacite.creators.creator.creatorName.fl_str_mv Brett, Christopher M. A.
Brett, Ana Maria Oliveira
Mitoseriu, Lucian Costel
datacite.date.Accepted.fl_str_mv 1994-10-01T00:00:00Z
datacite.rights.fl_str_mv http://purl.org/coar/access_right/c_abf2
datacite.titles.title.fl_str_mv Amperometric and Voltammetric Detection in Batch Injection Analysis
dc.contributor.none.fl_str_mv Estudo Geral
dc.creator.none.fl_str_mv Brett, Christopher M. A.
Brett, Ana Maria Oliveira
Mitoseriu, Lucian Costel
dc.date.Accepted.fl_str_mv 1994-10-01T00:00:00Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv https://hdl.handle.net/10316/10308
dc.language.none.fl_str_mv eng
dc.publisher.none.fl_str_mv American Chemical Society
dc.rights.none.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.title.fl_str_mv Amperometric and Voltammetric Detection in Batch Injection Analysis
dc.type.none.fl_str_mv http://purl.org/coar/resource_type/c_6501
description Batch injection analysis (BIA) enables the investigation of electrode reactions using extremely small volumes of analyte solution of 100 pL. The potentialities of amperometric and voltammetric detection have been examined by studying the oxidation of ferrocyanide and ascorbic acid at platinum electrodes and using sample volumes between 10 and 100 pL. The electrolysis efficiency as a function of injected volume has been addressed. Consecutive injections during a slow linear potential sweep permit the registering of a point-by-point pseudo-steady-state voltammetric curve and allow the measurement of thermodynamic and kinetic parameters as well as the determination of concentration. Cyclic voltammetry during or after injection can aid in mechanistic studies. The combination of BIA and square-wave voltammetry leads to a continuous voltammetric profile from a single injection using 100 p L calibration plots show a factor of 4 sensitivity increase relative to fixed-potential amperometric detection.
dirty 0
eu_rights_str_mv openAccess
format article
id estudogl_1c9b81f54bbcd5bbca7871505b3f1ebe
identifier.url.fl_str_mv https://hdl.handle.net/10316/10308
inst_facet_str urn:organizationAcronym:uc{{{_:::_}}}Universidade de Coimbra
instacron_str uc
institution Universidade de Coimbra
instname_str Universidade de Coimbra
language eng
network_acronym_str estudogl
network_name_str Estudo Geral - Universidade de Coimbra
oai_identifier_str oai:estudogeral.uc.pt:10316/10308
organization_str_mv urn:organizationAcronym:uc
person_str_mv Brett, Christopher M. A.
Brett, Ana Maria Oliveira
Mitoseriu, Lucian Costel
publishDate 1994
publisher.none.fl_str_mv American Chemical Society
repo_facet_str urn:repositoryAcronym:estudogl{{{_:::_}}}Estudo Geral - Universidade de Coimbra
reponame_str Estudo Geral - Universidade de Coimbra
repository_id_str urn:repositoryAcronym:estudogl
service_str_mv urn:repositoryAcronym:estudogl
spelling engAmerican Chemical SocietyengBatch injection analysis (BIA) enables the investigation of electrode reactions using extremely small volumes of analyte solution of 100 pL. The potentialities of amperometric and voltammetric detection have been examined by studying the oxidation of ferrocyanide and ascorbic acid at platinum electrodes and using sample volumes between 10 and 100 pL. The electrolysis efficiency as a function of injected volume has been addressed. Consecutive injections during a slow linear potential sweep permit the registering of a point-by-point pseudo-steady-state voltammetric curve and allow the measurement of thermodynamic and kinetic parameters as well as the determination of concentration. Cyclic voltammetry during or after injection can aid in mechanistic studies. The combination of BIA and square-wave voltammetry leads to a continuous voltammetric profile from a single injection using 100 p L calibration plots show a factor of 4 sensitivity increase relative to fixed-potential amperometric detection.application/pdfengAmperometric and Voltammetric Detection in Batch Injection AnalysisBrett, Christopher M. A.Brett, Ana Maria OliveiraMitoseriu, Lucian CostelHostingInstitutionOrganizationalEstudo Gerale-mailmailto:inf@sib.uc.ptinf@sib.uc.ptISSNIsPartOf0003-2700DOIIsPartOf10.1021/ac00091a0241994-101994-10-01T00:00:00ZHandlehttps://hdl.handle.net/10316/10308http://purl.org/coar/access_right/c_abf2open access521660 bytesliteraturehttp://purl.org/coar/resource_type/c_6501journal articleapplication/pdfhttps://estudogeral.uc.pt/bitstream/10316/10308/1/Amperometric%20and%20Voltammetric%20Detection.pdf
spellingShingle Amperometric and Voltammetric Detection in Batch Injection Analysis
Brett, Christopher M. A.
status SINGLETON
title Amperometric and Voltammetric Detection in Batch Injection Analysis
title_full Amperometric and Voltammetric Detection in Batch Injection Analysis
title_fullStr Amperometric and Voltammetric Detection in Batch Injection Analysis
title_full_unstemmed Amperometric and Voltammetric Detection in Batch Injection Analysis
title_short Amperometric and Voltammetric Detection in Batch Injection Analysis
title_sort Amperometric and Voltammetric Detection in Batch Injection Analysis
url https://hdl.handle.net/10316/10308
visible 1

Atividades financiadas

Não foram encontrados projetos financiados.