Architectural Design for Heartbeat Detection Circuits using Verilog-A Behavioral Modeling

Ver documento

Detalhes bibliográficos
Resumo:This work presents a study of two analog frontend circuit architectures for heartbeat detection. Both circuits present an amplification block as the first stage, followed by a band-pass filter. In the first, the heartbeat detection is done using an adaptive threshold based on pulse-width, whereas the heartbeat detection in the second is done using a sample and hold to find the maximum and minimum peak of each beating. Both architectures are modeled in Verilog-A and simulated using real-world ECG signals with different characteristics. This work studies possible fundamental analog circuit blocks suitable for wearable implementation. It evaluates critical performances requirements from the analysis of the behavior simulations. It was verified that the first circuit can properly detect heartbeats as long as the input-referred noise is below 21 μV, whereas the second one ensures it until 30 μV. The low cutoff frequency can be approximately 10 Hz without compromising the signal’s peaks, which means that these specifications can be relaxed substantially compared to systems intended to reconstruct the signal accurately.
Autores principais:Vieira, R.
Outros Autores:Passos, F.; Póvoa, R.; Martins, R.; Horta, N.; Guilherme, J.; Lourenço, N.
Assunto:Heartbeat Detection Healthcare Verilog-A
Ano:2022
País:Portugal
Tipo de documento:atas de conferência
Tipo de acesso:acesso restrito
Instituição associada:Escola Superior Náutica Infante D. Henrique
Idioma:inglês
Origem:Escola Superior Náutica Infante D. Henrique
_version_ 1876683542152347648
author Vieira, R.
author2 Passos, F.
Póvoa, R.
Martins, R.
Horta, N.
Guilherme, J.
Lourenço, N.
author2_role author
author
author
author
author
author
author_facet Vieira, R.
Passos, F.
Póvoa, R.
Martins, R.
Horta, N.
Guilherme, J.
Lourenço, N.
author_role author
contributor_name_str_mv Repositório Comum
country_str PT
creators_json_txt [{\"Person.name\":\"Vieira, R.\"},{\"Person.name\":\"Passos, F.\"},{\"Person.name\":\"Póvoa, R.\"},{\"Person.name\":\"Martins, R.\"},{\"Person.name\":\"Horta, N.\"},{\"Person.name\":\"Guilherme, J.\"},{\"Person.name\":\"Lourenço, N.\"}]
datacite.contributors.contributor.contributorName.fl_str_mv Repositório Comum
datacite.creators.creator.creatorName.fl_str_mv Vieira, R.
Passos, F.
Póvoa, R.
Martins, R.
Horta, N.
Guilherme, J.
Lourenço, N.
datacite.date.Accepted.fl_str_mv 2022-01-01T00:00:00Z
datacite.date.available.fl_str_mv 2025-09-18T13:12:34Z
datacite.date.embargoed.fl_str_mv 2025-09-18T13:12:34Z
datacite.rights.fl_str_mv http://purl.org/coar/access_right/c_16ec
datacite.subjects.subject.fl_str_mv Heartbeat Detection
Healthcare
Verilog-A
datacite.titles.title.fl_str_mv Architectural Design for Heartbeat Detection Circuits using Verilog-A Behavioral Modeling
dc.contributor.none.fl_str_mv Repositório Comum
dc.creator.none.fl_str_mv Vieira, R.
Passos, F.
Póvoa, R.
Martins, R.
Horta, N.
Guilherme, J.
Lourenço, N.
dc.date.Accepted.fl_str_mv 2022-01-01T00:00:00Z
dc.date.available.fl_str_mv 2025-09-18T13:12:34Z
dc.date.embargoed.fl_str_mv 2025-09-18T13:12:34Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://hdl.handle.net/10400.26/58719
dc.language.none.fl_str_mv eng
dc.publisher.none.fl_str_mv IEEE
dc.rights.cclincense.fl_str_mv http://creativecommons.org/licenses/by-nc/4.0/
dc.rights.none.fl_str_mv http://purl.org/coar/access_right/c_16ec
dc.subject.none.fl_str_mv Heartbeat Detection
Healthcare
Verilog-A
dc.title.fl_str_mv Architectural Design for Heartbeat Detection Circuits using Verilog-A Behavioral Modeling
dc.type.none.fl_str_mv http://purl.org/coar/resource_type/c_f744
description This work presents a study of two analog frontend circuit architectures for heartbeat detection. Both circuits present an amplification block as the first stage, followed by a band-pass filter. In the first, the heartbeat detection is done using an adaptive threshold based on pulse-width, whereas the heartbeat detection in the second is done using a sample and hold to find the maximum and minimum peak of each beating. Both architectures are modeled in Verilog-A and simulated using real-world ECG signals with different characteristics. This work studies possible fundamental analog circuit blocks suitable for wearable implementation. It evaluates critical performances requirements from the analysis of the behavior simulations. It was verified that the first circuit can properly detect heartbeats as long as the input-referred noise is below 21 μV, whereas the second one ensures it until 30 μV. The low cutoff frequency can be approximately 10 Hz without compromising the signal’s peaks, which means that these specifications can be relaxed substantially compared to systems intended to reconstruct the signal accurately.
dirty 0
eu_rights_str_mv restrictedAccess
format conferenceProceedings
fulltext.url.fl_str_mv https://comum.rcaap.pt/bitstreams/13ae7e31-1c70-432a-bb88-f906b54dcd57/download
id enidh_607ad258395895e0e7ded84dd463f9be
identifier.url.fl_str_mv http://hdl.handle.net/10400.26/58719
inst_facet_str urn:organizationAcronym:enidh{{{_:::_}}}Escola Superior Náutica Infante D. Henrique
instacron_str enidh
institution Escola Superior Náutica Infante D. Henrique
instname_str Escola Superior Náutica Infante D. Henrique
language eng
network_acronym_str enidh
network_name_str Escola Superior Náutica Infante D. Henrique
oai_identifier_str oai:comum.rcaap.pt:10400.26/58719
organization_str_mv urn:organizationAcronym:enidh
person_str_mv Vieira, R.
Passos, F.
Póvoa, R.
Martins, R.
Horta, N.
Guilherme, J.
Lourenço, N.
publishDate 2022
publisher.none.fl_str_mv IEEE
repo_facet_str urn:repositoryAcronym:enidh{{{_:::_}}}Escola Superior Náutica Infante D. Henrique
reponame_str Escola Superior Náutica Infante D. Henrique
repository_id_str urn:repositoryAcronym:enidh
service_str_mv urn:repositoryAcronym:enidh
spelling engIEEEengThis work presents a study of two analog frontend circuit architectures for heartbeat detection. Both circuits present an amplification block as the first stage, followed by a band-pass filter. In the first, the heartbeat detection is done using an adaptive threshold based on pulse-width, whereas the heartbeat detection in the second is done using a sample and hold to find the maximum and minimum peak of each beating. Both architectures are modeled in Verilog-A and simulated using real-world ECG signals with different characteristics. This work studies possible fundamental analog circuit blocks suitable for wearable implementation. It evaluates critical performances requirements from the analysis of the behavior simulations. It was verified that the first circuit can properly detect heartbeats as long as the input-referred noise is below 21 μV, whereas the second one ensures it until 30 μV. The low cutoff frequency can be approximately 10 Hz without compromising the signal’s peaks, which means that these specifications can be relaxed substantially compared to systems intended to reconstruct the signal accurately.application/pdfengArchitectural Design for Heartbeat Detection Circuits using Verilog-A Behavioral ModelingVieira, R.Passos, F.Póvoa, R.Martins, R.Horta, N.Guilherme, J.Lourenço, N.HostingInstitutionOrganizationalRepositório Comume-mailmailto:comum@rcaap.ptcomum@rcaap.ptDOIIsPartOf10.1109/SMACD55068.2022.98162532025-09-18T13:12:34Z20222022-01-01T00:00:00ZHandlehttp://hdl.handle.net/10400.26/58719http://purl.org/coar/access_right/c_16ecrestricted accessHeartbeat DetectionHealthcareVerilog-A1605466 bytesother research producthttp://purl.org/coar/resource_type/c_f744conference proceedings2022http://creativecommons.org/licenses/by-nc/4.0/http://purl.org/coar/access_right/c_16ecapplication/pdffulltexthttps://comum.rcaap.pt/bitstreams/13ae7e31-1c70-432a-bb88-f906b54dcd57/downloadProceedings - 2022 18th International Conference on Synthesis, Modeling, Analysis and Simulation Methods, and Applications to Circuit Design, SMACD 202214Villasimius, Itália2022-12-06
spellingShingle Architectural Design for Heartbeat Detection Circuits using Verilog-A Behavioral Modeling
Vieira, R.
Heartbeat Detection
Healthcare
Verilog-A
status SINGLETON
subject.fl_str_mv Heartbeat Detection
Healthcare
Verilog-A
title Architectural Design for Heartbeat Detection Circuits using Verilog-A Behavioral Modeling
title_full Architectural Design for Heartbeat Detection Circuits using Verilog-A Behavioral Modeling
title_fullStr Architectural Design for Heartbeat Detection Circuits using Verilog-A Behavioral Modeling
title_full_unstemmed Architectural Design for Heartbeat Detection Circuits using Verilog-A Behavioral Modeling
title_short Architectural Design for Heartbeat Detection Circuits using Verilog-A Behavioral Modeling
title_sort Architectural Design for Heartbeat Detection Circuits using Verilog-A Behavioral Modeling
topic Heartbeat Detection
Healthcare
Verilog-A
topic_facet Heartbeat Detection
Healthcare
Verilog-A
url http://hdl.handle.net/10400.26/58719
visible 1

Atividades financiadas

Não foram encontrados projetos financiados.