Publicação

One size does not fit all – Staged hybrid approach of a challenging aortic arch aneurysm using a double-branch custom-made device

Ver documento

Detalhes bibliográficos
Resumo:Background: The anatomical complexity of the aortic arch poses significant challenges to its repair, particularly in high-risk patients. The introduction of branched endografts, specifically designed to overcome these challenges, has revolutionized this field as demonstrated in the present case-report.   Report: A 60-year-old male, with a prior history of smoking and neurosyphilis, was referenced to our outpatient clinic due to a CT finding of a 66mm aortic arch aneurysm with complex anatomical features, including a short brachiocephalic trunk and narrow iliac arteries. Thus, a staged hybrid approach was meticulously planned. The patient was initially submitted to a left carotid-subclavian bypass, followed by a right subclavian-carotid bypass. Later, an endoconduit was constructed using two GORE-Viabahn® stent grafts (11x100mm), deployed in the left common and external iliac arteries, facilitating subsequent TEVAR. Finally, the aneurysm was excluded using a custom-made Terumo-Relay® double inner-branched endograft (46x32x270mm) deployed in zone 0, with two inner branches for the brachiocephalic trunk (BCT)/right subclavian artery (RSA) and left common carotid artery (LCCA). The inner branches were catheterized via trans-carotid (left) and trans-axillary (right) accesses. An iliac extension GORE-Excluder® (16x12x100mm) to the BCT/RSA and a GORE-Viabahn® stent graft (7x75mm) to the LCCA were deployed. An additional extension endograft (34x30x150mm) was deployed to complete distal exclusion. The left subclavian artery was subsequently occluded using a vascular plug. Postoperatively, the patient experienced a minor posterior circulation stroke, with full recovery within two weeks. Six-month follow-up imaging showed patency of the endografts with complete exclusion of the aneurysm and no evidence of endoleaks. The patient remained asymptomatic, with no further vascular or neurological events.   Conclusion: This case highlights the feasibility of a staged hybrid approach for complex aortic arch aneurysms in patients with challenging anatomy. The use of a custom-made endograft and careful preoperative planning proved critical to the success of the procedure.
Autores principais:Carvalho, Patrícia
Outros Autores:Brandão, Daniel; Fernandes, Luís; Machado, Marta; Basílio, Francisco; Guimarães, Beatriz; Rocha, Ana Margarida; Canedo, Alexandra
Assunto:Endovascular Aneurysm Repair (MeSH) Branched TEVAR Hybrid procedures Aortic Aneurysm, Thoracic (MeSH) Stroke (MeSH)
Ano:2026
País:Portugal
Tipo de documento:artigo
Tipo de acesso:unknown
Instituição associada:Sociedade Portuguesa de Angiologia e Cirurgia Vascular
Idioma:inglês
Origem:Angiologia e Cirurgia Vascular
_version_ 1869051323200045056
author Carvalho, Patrícia
author2 Brandão, Daniel
Fernandes, Luís
Machado, Marta
Basílio, Francisco
Guimarães, Beatriz
Rocha, Ana Margarida
Canedo, Alexandra
author2_role author
author
author
author
author
author
author
author_facet Carvalho, Patrícia
Brandão, Daniel
Fernandes, Luís
Machado, Marta
Basílio, Francisco
Guimarães, Beatriz
Rocha, Ana Margarida
Canedo, Alexandra
author_role author
country_str PT
creators_json_txt [{\"Person.name\":\"Carvalho, Patrícia\"},{\"Person.name\":\"Brandão, Daniel\"},{\"Person.name\":\"Fernandes, Luís\"},{\"Person.name\":\"Machado, Marta\"},{\"Person.name\":\"Basílio, Francisco\"},{\"Person.name\":\"Guimarães, Beatriz\"},{\"Person.name\":\"Rocha, Ana Margarida\"},{\"Person.name\":\"Canedo, Alexandra\"}]
datacite.creators.creator.creatorName.fl_str_mv Carvalho, Patrícia
Brandão, Daniel
Fernandes, Luís
Machado, Marta
Basílio, Francisco
Guimarães, Beatriz
Rocha, Ana Margarida
Canedo, Alexandra
datacite.rights.fl_str_mv http://purl.org/coar/access_right/c_abf2
datacite.subjects.subject.fl_str_mv Endovascular Aneurysm Repair (MeSH)
Branched TEVAR
Hybrid procedures
Aortic Aneurysm, Thoracic (MeSH)
Stroke (MeSH)
datacite.titles.title.fl_str_mv One size does not fit all – Staged hybrid approach of a challenging aortic arch aneurysm using a double-branch custom-made device
dc.creator.none.fl_str_mv Carvalho, Patrícia
Brandão, Daniel
Fernandes, Luís
Machado, Marta
Basílio, Francisco
Guimarães, Beatriz
Rocha, Ana Margarida
Canedo, Alexandra
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv https://doi.org/10.48750/acv.689
dc.language.none.fl_str_mv eng
dc.publisher.none.fl_str_mv Sociedade Portuguesa de Angiologia e Cirurgia Vascular
dc.rights.none.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.source.none.fl_str_mv Angiologia e Cirurgia Vascular; Vol. 22 No. 1 (2026): March; 37 - 39
Angiologia e Cirurgia Vascular; Vol. 22 N.º 1 (2026): Março; 37 - 39
2183-0096
1646-706X
dc.subject.none.fl_str_mv Endovascular Aneurysm Repair (MeSH)
Branched TEVAR
Hybrid procedures
Aortic Aneurysm, Thoracic (MeSH)
Stroke (MeSH)
dc.title.fl_str_mv One size does not fit all – Staged hybrid approach of a challenging aortic arch aneurysm using a double-branch custom-made device
dc.type.none.fl_str_mv http://purl.org/coar/resource_type/c_6501
description Background: The anatomical complexity of the aortic arch poses significant challenges to its repair, particularly in high-risk patients. The introduction of branched endografts, specifically designed to overcome these challenges, has revolutionized this field as demonstrated in the present case-report.   Report: A 60-year-old male, with a prior history of smoking and neurosyphilis, was referenced to our outpatient clinic due to a CT finding of a 66mm aortic arch aneurysm with complex anatomical features, including a short brachiocephalic trunk and narrow iliac arteries. Thus, a staged hybrid approach was meticulously planned. The patient was initially submitted to a left carotid-subclavian bypass, followed by a right subclavian-carotid bypass. Later, an endoconduit was constructed using two GORE-Viabahn® stent grafts (11x100mm), deployed in the left common and external iliac arteries, facilitating subsequent TEVAR. Finally, the aneurysm was excluded using a custom-made Terumo-Relay® double inner-branched endograft (46x32x270mm) deployed in zone 0, with two inner branches for the brachiocephalic trunk (BCT)/right subclavian artery (RSA) and left common carotid artery (LCCA). The inner branches were catheterized via trans-carotid (left) and trans-axillary (right) accesses. An iliac extension GORE-Excluder® (16x12x100mm) to the BCT/RSA and a GORE-Viabahn® stent graft (7x75mm) to the LCCA were deployed. An additional extension endograft (34x30x150mm) was deployed to complete distal exclusion. The left subclavian artery was subsequently occluded using a vascular plug. Postoperatively, the patient experienced a minor posterior circulation stroke, with full recovery within two weeks. Six-month follow-up imaging showed patency of the endografts with complete exclusion of the aneurysm and no evidence of endoleaks. The patient remained asymptomatic, with no further vascular or neurological events.   Conclusion: This case highlights the feasibility of a staged hybrid approach for complex aortic arch aneurysms in patients with challenging anatomy. The use of a custom-made endograft and careful preoperative planning proved critical to the success of the procedure.
dirty 0
eu_rights_str_mv unknown
format article
id acv_b280b800311a10899d179db6c7363d35
identifier.doi.fl_str_mv https://doi.org/10.48750/acv.689
inst_facet_str urn:organizationAcronym:spacv{{{_:::_}}}Sociedade Portuguesa de Angiologia e Cirurgia Vascular
instacron_str SPACV
institution Sociedade Portuguesa de Angiologia e Cirurgia Vascular
instname_str Sociedade Portuguesa de Angiologia e Cirurgia Vascular
language eng
network_acronym_str acv
network_name_str Angiologia e Cirurgia Vascular
oai_identifier_str oai:ojs.acvjournal.com:article/689
organization_str_mv urn:organizationAcronym:spacv
person_str_mv Carvalho, Patrícia
Brandão, Daniel
Fernandes, Luís
Machado, Marta
Basílio, Francisco
Guimarães, Beatriz
Rocha, Ana Margarida
Canedo, Alexandra
publishDate 2026
publisher.none.fl_str_mv Sociedade Portuguesa de Angiologia e Cirurgia Vascular
repo_facet_str urn:repositoryAcronym:acv{{{_:::_}}}Angiologia e Cirurgia Vascular
reponame_str Angiologia e Cirurgia Vascular
repository_id_str urn:repositoryAcronym:acv
service_str_mv urn:repositoryAcronym:acv
spelling en-USOne size does not fit all – Staged hybrid approach of a challenging aortic arch aneurysm using a double-branch custom-made deviceCarvalho, PatríciaBrandão, DanielFernandes, LuísMachado, MartaBasílio, FranciscoGuimarães, BeatrizRocha, Ana MargaridaCanedo, AlexandraEndovascular Aneurysm Repair (MeSH)Branched TEVARHybrid proceduresAortic Aneurysm, Thoracic (MeSH)Stroke (MeSH)Copyright (c) 2026 Angiologia e Cirurgia Vascularhttp://purl.org/coar/access_right/c_abf2https://doi.org/10.48750/acv.689DOIhttps://acvjournal.com/index.php/acv/article/view/689URLHasVersionhttps://acvjournal.com/index.php/acv/article/view/689/454URLHasVersionhttps://doi.org/10.48750/acv.689DOI2026-06-23en-USBackground: The anatomical complexity of the aortic arch poses significant challenges to its repair, particularly in high-risk patients. The introduction of branched endografts, specifically designed to overcome these challenges, has revolutionized this field as demonstrated in the present case-report.   Report: A 60-year-old male, with a prior history of smoking and neurosyphilis, was referenced to our outpatient clinic due to a CT finding of a 66mm aortic arch aneurysm with complex anatomical features, including a short brachiocephalic trunk and narrow iliac arteries. Thus, a staged hybrid approach was meticulously planned. The patient was initially submitted to a left carotid-subclavian bypass, followed by a right subclavian-carotid bypass. Later, an endoconduit was constructed using two GORE-Viabahn® stent grafts (11x100mm), deployed in the left common and external iliac arteries, facilitating subsequent TEVAR. Finally, the aneurysm was excluded using a custom-made Terumo-Relay® double inner-branched endograft (46x32x270mm) deployed in zone 0, with two inner branches for the brachiocephalic trunk (BCT)/right subclavian artery (RSA) and left common carotid artery (LCCA). The inner branches were catheterized via trans-carotid (left) and trans-axillary (right) accesses. An iliac extension GORE-Excluder® (16x12x100mm) to the BCT/RSA and a GORE-Viabahn® stent graft (7x75mm) to the LCCA were deployed. An additional extension endograft (34x30x150mm) was deployed to complete distal exclusion. The left subclavian artery was subsequently occluded using a vascular plug. Postoperatively, the patient experienced a minor posterior circulation stroke, with full recovery within two weeks. Six-month follow-up imaging showed patency of the endografts with complete exclusion of the aneurysm and no evidence of endoleaks. The patient remained asymptomatic, with no further vascular or neurological events.   Conclusion: This case highlights the feasibility of a staged hybrid approach for complex aortic arch aneurysms in patients with challenging anatomy. The use of a custom-made endograft and careful preoperative planning proved critical to the success of the procedure.Sociedade Portuguesa de Angiologia e Cirurgia Vascularapplication/pdfen-USAngiologia e Cirurgia Vascular; Vol. 22 No. 1 (2026): March; 37 - 39pt-PTAngiologia e Cirurgia Vascular; Vol. 22 N.º 1 (2026): Março; 37 - 392183-00961646-706Xengjournal articlehttp://purl.org/coar/resource_type/c_6501literatureVoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85
spellingShingle One size does not fit all – Staged hybrid approach of a challenging aortic arch aneurysm using a double-branch custom-made device
Carvalho, Patrícia
Endovascular Aneurysm Repair (MeSH)
Branched TEVAR
Hybrid procedures
Aortic Aneurysm, Thoracic (MeSH)
Stroke (MeSH)
status SINGLETON
status_str VoR
subject.fl_str_mv Endovascular Aneurysm Repair (MeSH)
Branched TEVAR
Hybrid procedures
Aortic Aneurysm, Thoracic (MeSH)
Stroke (MeSH)
title One size does not fit all – Staged hybrid approach of a challenging aortic arch aneurysm using a double-branch custom-made device
title_full One size does not fit all – Staged hybrid approach of a challenging aortic arch aneurysm using a double-branch custom-made device
title_fullStr One size does not fit all – Staged hybrid approach of a challenging aortic arch aneurysm using a double-branch custom-made device
title_full_unstemmed One size does not fit all – Staged hybrid approach of a challenging aortic arch aneurysm using a double-branch custom-made device
title_short One size does not fit all – Staged hybrid approach of a challenging aortic arch aneurysm using a double-branch custom-made device
title_sort One size does not fit all – Staged hybrid approach of a challenging aortic arch aneurysm using a double-branch custom-made device
topic Endovascular Aneurysm Repair (MeSH)
Branched TEVAR
Hybrid procedures
Aortic Aneurysm, Thoracic (MeSH)
Stroke (MeSH)
topic_facet Endovascular Aneurysm Repair (MeSH)
Branched TEVAR
Hybrid procedures
Aortic Aneurysm, Thoracic (MeSH)
Stroke (MeSH)
url https://doi.org/10.48750/acv.689
visible 1

Atividades financiadas

Não foram encontrados projetos financiados.