Resultados da pesquisa - "Vaz,M. Carmo V.F."

Catálogo de Publicações - "Vaz,M. Carmo V.F."

Filtros
  1. 1

    Development of an FIA system with amperometric detection for determination of bentazone in estuarine waters

    Publicação
    por Cerejeira, Rodrigo P. A. G.
    Outros Autores: Delerue-Matos, Cristina; Vaz, M. Carmo V. F.
    On the basis of its electrochemical behaviour a new flow-injection analysis (FIA) method with amperometric detection has been developed for quantification of the herbicide bentazone (BTZ) in estuarine waters. Standard solutions and samples (200 µL) were injected into a water carrier stream and both pH and ionic strength were automatically adjusted inside the manifold. Optimization of critical FIA conditions indicated that the best analytical results were obtained at an oxidation potential of 1.10 V, pH 4.5, and an overall flow-rate of 2.4 mL min–1. Analysis of real samples was performed by means of calibration curves over the concentration range 2.5x10–6 to 5.0x10–5 mol L–1, and results were compared with those obtained by use of an independent method (HPLC). The accuracy of the amperometric determinations was ascertained; errors relative to the comparison method were below 4% and sampling rates were approximately 100 samples h–1. The repeatability of the proposed method was calculated by assessing the relative standard deviation (%) of ten consecutive determinations of one sample; the value obtained was 2.1%.
    2002 artigo Portugal acesso aberto
  2. 2

    Enzymatic determination of choline in milk using a FIA system with potentiometric detection

    Publicação
    por Lima, J. L. F. C.
    Outros Autores: Delerue-Matos, Cristina; Vaz, M. Carmo V. F.
    The development of a FIA system for the determination of total choline content in several types of milk is described. The samples were submitted to hydrochloric acid digestion before injection into the system and passed through an enzymatic reactor containing choline oxidase immobilised on glass beads. This enzymatic reaction releases hydrogen peroxide which then reacts with a solution of iodide. The decrease in the concentration of iodide ion is quantified using an iodide ion selective tubular electrode based on a homogeneous crystalline membrane. Validation of the results obtained with this system was performed by comparison with results from a method described in the literature and applied to the determination of total choline in milks. The relative deviation was always < 5%. The repeatability of the method developed was assessed by calculation of the relative standard deviation (RSD) for 12 consecutive injections of one sample. The RSD obtained was < 0.6%.
    2000 artigo Portugal acesso aberto
  3. 3

    Study of the voltammetric behaviour of metam and its application to an amperometric flow system

    Publicação
    por Barroso, M. Fátima
    Outros Autores: Paíga, Paula; Vaz, M. Carmo V. F.; Delerue-Matos, Cristina
    The electrochemical behaviour of the pesticide metam (MT) at a glassy carbon working electrode (GCE) and at a hanging mercury drop electrode (HMDE) was investigated. Different voltammetric techniques, including cyclic voltammetry (CV) and square wave voltammetry (SWV), were used. An anodic peak (independent of pH) at +1.46 V vs AgCl/Ag was observed in MTaqueous solution using the GCE. SWV calibration curves were plotted under optimized conditions (pH 2.5 and frequency 50 Hz), which showed a linear response for 17–29 mg L−1. Electrochemical reduction was also explored, using the HMDE. A well defined cathodic peak was recorded at −0.72 V vs AgCl/ Ag, dependent on pH. After optimizing the operating conditions (pH 10.1, frequency 150 Hz, potential deposition −0.20 V for 10 s), calibration curves was measured in the concentration range 2.5×10−1 to 1.0 mg L−1 using SWV. The electrochemical behaviour of this compound facilitated the development of a flow injection analysis (FIA) system with amperometric detection for the quantification of MT in commercial formulations and spiked water samples. An assessment of the optimal FIA conditions indicated that the best analytical results were obtained at a potential of +1.30 V, an injection volume of 207 μL and an overall flow rate of 2.4 ml min−1. Real samples were analysed via calibration curves over the concentration range 1.3×10−2 to 1.3 mg L−1. Recoveries from the real samples (spiked waters and commercial formulations) were between 97.4 and 105.5%. The precision of the proposed method was evaluated by assessing the relative standard deviation (RSD %) of ten consecutive determinations of one sample (1.0 mg L−1), and the value obtained was 1.5%.
    2005 artigo Portugal acesso aberto
  4. 4

    Square-wave voltametric method for determination of molinate concentration in a biological process using a hanging mercury drop electrode

    Publicação
    por Barroso, M. Fátima
    Outros Autores: Nunes, O. C.; Vaz, M. Carmo V. F.; Delerue-Matos, Cristina
    A square-wave voltammetric (SWV) method using a hanging mercury drop electrode (HMDE) has been developed for determination of the herbicide molinate in a biodegradation process. The method is based on controlled adsorptive accumulation of molinate for 10 s at a potential of -0.8 V versus AgCl/Ag. An anodic peak, due to oxidation of the adsorbed pesticide, was observed in the cyclic voltammogram at ca. -0.320 V versus AgCl/Ag; a very small cathodic peak was also detected. The SWV calibration plot was established to be linear in the range 5.0x10-6 to 9.0x10-6 mol L-1; this corresponded to a detection limit of 3.5x10-8 mol L-1. This electroanalytical method was used to monitor the decrease of molinate concentration in river waters along a biodegradation process using a bacterial mixed culture. The results achieved with this voltammetric method were compared with those obtained by use of a chromatographic method (HPLC–UV) and no significant statistical differences were observed.
    2005 artigo Portugal acesso aberto
  5. 5

    Citrate selective electrodes for the flow injection analysis of soft drinks, beers and pharmaceutical products

    Publicação
    por Ribeiro, Cristina M. F.
    Outros Autores: Delerue-Matos, Cristina; Sales, M. Goreti F.; Vaz, M. Carmo V. F.
    Aiming the establishment of simple and accurate readings of citric acid (CA) in complex samples, citrate (CIT) selective electrodes with tubular configuration and polymeric membranes plus a quaternary ammonium ion exchanger were constructed. Several selective membranes were prepared for this purpose, having distinct mediator solvents (with quite different polarities) and, in some cases, p-tert-octylphenol (TOP) as additive. The latter was used regarding a possible increase in selectivity. The general working characteristics of all prepared electrodes were evaluated in a low dispersion flow injection analysis (FIA) manifold by injecting 500µl of citrate standard solutions into an ionic strength (IS) adjuster carrier (10−2 mol l−1) flowing at 3ml min−1. Good potentiometric response, with an average slope and a repeatability of 61.9mV per decade and ±0.8%, respectively, resulted from selective membranes comprising additive and bis(2-ethylhexyl)sebacate (bEHS) as mediator solvent. The same membranes conducted as well to the best selectivity characteristics, assessed by the separated solutions method and for several chemical species, such as chloride, nitrate, ascorbate, glucose, fructose and sucrose. Pharmaceutical preparations, soft drinks and beers were analyzed under conditions that enabled simultaneous pH and ionic strength adjustment (pH = 3.2; ionic strength = 10−2 mol l−1), and the attained results agreed well with the used reference method (relative error < 4%). The above experimental conditions promoted a significant increase in sensitivity of the potentiometric response, with a supra-Nernstian slope of 80.2mV per decade, and allowed the analysis of about 90 samples per hour, with a relative standard deviation <1.0%.
    2002 artigo Portugal acesso aberto
  6. 6

    Cathodic Behaviour of Cysteine at a Platinum Electrode

    Publicação
    por Barroso,M. Fátima
    Outros Autores: Santos,Teresa; Sales,M. Goreti F.; Delerue-Matos,Cristina; Vaz,M. Carmo V. F.
    Origem: SciELO Portugal
    The electroreduction behaviour of cysteine was investigated using cyclic, square wave and differencial pulse voltammetric techniques at a platinum working electrode. The reduction of cysteine occurs at a potential of -0.36 V independent of pH. It is a reversible process, controlled mainly by diffusion and in the mechanism of reduction 1 electron per molecule is involved. Using the voltammetric techniques: Cyclic Voltammetry, Square Wave Voltammetry and Differencial Pulse Voltammetry, different parameters (pH, frequency, step potential, pulse amplitude, scan rate) were optimized in order to develop an electrochemical procedure for determination of cysteine in pharmaceutical products. The repeatability, reproducibility, precision and accuracy of the methods were studied. No electroactive interferences from the excipient were found in the pharmaceutical compounds.
    2007 artigo Portugal acesso aberto
  7. 7

    Chemically Modified Carbon Paste Electrodes for Ascorbic Acid Determination in Soft Drinks by Flow Injection Amperometric Analysis

    Publicação
    por Sales,M. Goreti F.
    Outros Autores: Castanheira,M.S.A.; Ferreira,Rosa M.S.; Vaz,M. Carmo V.F.; Delerue-Matos,Cristina
    Origem: SciELO Portugal
    Simple, rapid and precise amperometric methods for quantification of ascorbic acid (AA) are presented. Glassy carbon (GC), carbon paste (CP) and modified carbon paste (MCP) electrodes are used for this purpose. MCP electrodes are of CP with 10 % vanadate (V). All electrodes are inserted in a wall-jet device with an Ag/AgCl reference electrode and a platinum auxiliary electrode. This device is coupled to a flow injection analysis (FIA) set-up. Hydrodynamic and amperometric parameters are optimized unvaryingly. GC electrodes present slopes of 4.75 ´ 10(5) nA L mol-1 (± 6.4 %) under optimum conditions. CP and MCP electrodes show higher sensitivity, with slopes of 6.37 ´ 10(5) nA L mol-1 (± 6.6 %) and 7.32 ´ 10(5) nA L mol-1 (± 4.4 %). Linear responses range (1.0-2.0) ´ 10-6 to (0.8-1.0) ´ 10-5 mol L-1. Correlation coefficients were > 0.994 and about 48 samples are analysed per hour. Application of the proposed method to the analysis of soft drinks is presented.
    2008 artigo Portugal acesso aberto
  8. 8

    Electroanalytical study of the pesticide ethiofencarb

    Publicação
    por Barroso, M. Fátima
    Outros Autores: Vaz, M. Carmo V. F.; Sales, M. Goreti F.; Paíga, Paula; Delerue-Matos, Cristina
    A detailed study of voltammetric behavior of ethiofencarb (ETF) is reported using glassy carbon electrode (GCE) and hanging mercury drop electrode (HMDE). With GCE, it is possible to verify that the oxidative mechanism is irreversible, independent of pH, and the maximum intensity current was observed at +1.20 V vs. AgCl/Ag at pH 1.9. A linear calibration line was obtained from 1.0x10-4 to 8.0x10-4 mol L-1 with SWV method. To complete the electrochemical knowledge of ETF pesticide, the reduction was also explored with HMDE. A well-defined peak was observed at –1.00V vs. AgCl/Ag in a large range of pH with higher signal at pH 7.0. Linearity was obtained in 4.2x10-6 and 9.4x10-6 mol L-1 ETF concentration range. An immediate alkaline hydrolysis of ETF was executed, producing a phenolic compound (2-ethylthiomethylphenol) (EMP), and the electrochemical activity of the product was examined. It was deduced that it is oxidized on GCE at +0.75V vs. AgCl/Ag with a maximum peak intensity current at pH 3.2, but the compound had no reduction activity on HMDE. Using the decrease of potential peak, a flow injection analysis (FIA) system was developed connected to an amperometric detector, enabling the determination of EMP over concentration range of 1.0x10-7 and 1.0x10-5 mol L-1 at a sampling rate of 60 h-1. The results provided by FIA methodology were performed by comparison with results from high-performance liquid chromatography (HPLC) technique and demonstrated good agreement with relative deviations lower than 4%. Recovery trials were performed and the obtained values were between 98 and 104%.
    2006 artigo Portugal acesso aberto
  9. 9

    Amperometric and spectrophotometric determination of carbaryl in natural waters and commercial formulations

    Publicação
    por Portela, Dionísia C.
    Outros Autores: Pereira, Isabel M. F.; Paíga, Paula; Delerue-Matos, Cristina; Vaz, M. Carmo V. F.
    The work presented describes the development and evaluation of two flow-injection analysis (FIA) systems for the automated determination of carbaryl in spiked natural waters and commercial formulations. Samples are injected directly into the system where they are subjected to alkaline hydrolysis thus forming 1-naphthol. This product is readily oxidised at a glassy carbon electrode. The electrochemical behaviour of 1-naphthol allows the development of an FIA system with an amperometric detector in which 1-naphthol determination, and thus measurement of carbaryl concentration, can be performed. Linear response over the range 1.0×10–7 to 1.0×10–5 mol L–1, with a sampling rate of 80 samples h–1, was recorded. The detection limit was 1.0×10–8 mol L–1. Another FIA manifold was constructed but this used a colorimetric detector. The methodology was based on the coupling of 1-naphthol with phenylhydrazine hydrochloride to produce a red complex which has maximum absorbance at 495 nm. The response was linear from 1.0×10–5 to 1.5×10–3 mol L–1 with a detection limit of 1.0×10–6 mol L–1. Sample-throughput was about 60 samples h–1. Validation of the results provided by the two FIA methodologies was performed by comparing them with results from a standard HPLC–UV technique. The relative deviation was <5%. Recovery trials were also carried out and the values obtained ranged from 97.0 to 102.0% for both methods. The repeatability (RSD, %) of 12 consecutive injections of one sample was 0.8% and 1.6% for the amperometric and colorimetric systems, respectively.
    2003 artigo Portugal acesso aberto
  10. 10

    Maltol determination in food by microwave assisted extraction and electrochemical detection

    Publicação
    por Barroso, M. Fátima
    Outros Autores: Sales, M. Goreti F.; Almeida, Sofia A. A.; Vaz, M. Carmo V. F.; Delerue-Matos, Cristina
    An electrochemical method is proposed for the determination of maltol in food. Microwave-assisted extraction procedures were developed to assist sample pre-treating steps. Experiments carried out in cyclic voltammetry showed an irreversible and adsorption controlled reduction of maltol. A cathodic peak was observed at -1.0 V for a Hanging Mercury Drop Electrode versus an AgCl/Ag (in saturated KCl), and the peak potential was pH independent. Square wave voltammetric procedures were selected to plot calibration curves. These procedures were carried out with the optimum conditions: pH 6.5; frequency 50 Hz; deposition potential 0.6 V; and deposition time 10 s. A linear behaviour was observed within 5.0 × 10-8 and 3.5 × 10-7 M. The proposed method was applied to the analysis of cakes, and results were compared with those obtained by an independent method. The voltammetric procedure was proven suitable for the analysis of cakes and provided environmental and economical advantages, including reduced toxicity and volume of effluents and decreased consumption of reagents.
    2008 artigo Portugal acesso aberto