Search Results - "Reyes,Felix G. R."

Publication Catalog - "Reyes,Felix G. R."

Refine Results
  1. 1
  2. 2
  3. 3

    Drosophila melanogaster Meigen: 3. sensibilidade ao carbofuran e biomonitoramento de seus resíduos em repolho

    Publication
    by Almeida,Garcia Rodrigues de
    Other Authors: Reyes,Felix G. R.; Rath,Susanne
    Origin: Oasisbr
    The susceptibility of Drosophila melanogaster to carbofuran and the use of this organism in biomonitoring residues of the insecticide in cabbage was evaluated. Under the conditions of the bioassay, residues-film bioassay in Petri dish, carbofuran degraded depending on the temperature and time of exposure. Bioassays conducted with D. melanogaster showed that its toxicity increases with temperature (20 to 35 °C). LC50 values, calculated as a function of temperature, ranged from 3.6 to 10.5 mg/g body weight (bw) for males and from 2.9 to 8.7 mg/g bw for females. The formulated product Furadan® G was applied on cabbage (Brassica oleracea, var. capitata) and the residues of carbofuran were determined by bioassay. The determination limit of the bioassay was 0.1 mg/kg and the method presented reproducibility with coefficient variation of 17 %. The validation of the bioassay by high performance liquid chromatography confirms the viability of the bioassay with D. melanogaster in monitoring the residues of carbofuran in cabbage.
    2001 article Brazil open access
  4. 4

    Estabilidade térmica de embalagens de poli (tereftalato de etileno (PET): determinação de Oligômeros

    Publication
    by Freire,Maria Teresa de A.
    Other Authors: Reyes,Felix G. R.; Castle,Laurence
    Origin: Oasisbr
    RESUMO: Embalagens plásticas para alimentos contendo poli(tereftalato de etileno (PET) foram submetidas a diversas condições de aquecimento. Oligômeros foram identificados por cromatografia líquida de alta eficiência acoplada à espectrometria de massas, quantificados e usados como parâmetro de avaliação da estabilidade térmica do PET. Pequenas variações foram verificadas na distribuição dos oligômeros unicamente nas amostras aquecidas a 230 °C, o que sugere estabilidade térmica do PET nas condições de aquecimento utilizadas. Os resultados obtidos indicam que o uso do polímero é adequado para utilização como material de embalagem para alimentos a serem aquecidos em fornos convencionais ou de microondas.
    1998 article Brazil open access
  5. 5

    Aspectos analíticos e regulatórios na determinação de resíduos de macrolídeos em alimentos de origem animal por cromatografia líquida associada à espectrometria de massas

    Publication
    by Sismotto,Marcela
    Other Authors: Paschoal,Jonas Augusto Rizzato; Reyes,Felix G. R.
    Origin: Oasisbr
    This is an overview of LC-MS techniques applied for macrolide determination in food, including sample preparation and method validation, as well as the policies adopted by international agencies regarding their presence in food. Techniques for the analysis of macrolides in food normally include solid phase or liquid-liquid extraction followed by HPLC. UHPLC presents advantages in running time, detectability and solvent consumption. Triple-quadrupoles are the most common analyzers in instruments used for the determination of contaminants in food, but time-of-flight and ion-trap spectrometers have been successfully applied for analyses focusing on the investigation of structural formula or the presence of degradation products.
    2013 article Brazil open access
  6. 6

    Comportamento eletroquímico da N-nitrosotiazolidina ácido carboxílico sobre eletrodos de ouro e mercúrio

    Publication
    by Codognoto,Lucia
    Other Authors: Reyes,Felix G. R.; Winter,Eduardo; Rath,Susanne
    Origin: Oasisbr
    The electrochemical behavior of N-nitrosothiazolidine carboxylic acid (NTAC) on gold and hanging mercury electrodes, using the cyclic and square wave voltammetries, was studied. Whereas NTAC suffer reduction in a single step on the mercury electrode, two peaks appears on the cyclic voltammograms on the gold electrode, one anodic peak overlaying the gold oxide process at 1.2 V and one cathodic peak at -0.41 V vs Ag/AgCl, KCl 3.0 mol L-1. The cathodic peak depends on the previous oxidation of NTAC at the electrode surface, presents irreversible and adsorption controlled characteristics and it is suitable for quantitative purposes.
    2008 article Brazil open access
  7. 7

    GC-MS determination of organochlorine pesticides in medicinal plants harvested in Brazil

    Publication
    by Rodrigues,Marili V.N.
    Other Authors: Reyes,Felix G. R.; Magalhães,Pedro M.; Rath,Susanne
    Origin: Oasisbr
    A method using Gas Chromatography coupled to Mass Spectrometry (GC-MS) for the determination of hexachlorobenzene, lindane, heptachlor, heptachlor epoxide, aldrin, dieldrin, endrin, 4,4'-DDT and 4,4'-DDE in leaves of Mikania laevigata, Maytenus ilicifolia and Cordia verbenacea was developed. Extraction of the pesticides was carried out by solid-liquid extraction (SLE), followed by clean-up in solid phase mixed cartridge (Florisil and silica-gel). Quantification was performed using GC-MS in the selected ion monitoring mode. Mean recovery rates of 70 to 124% were obtained. The inter-assay precision of a sample fortified with 200 ng g-1 of each pesticide was in the range of 1.0 to 7.3%. The quantitation limits ranged from 3.0 to 30 ng g-1 and were below the Maximum Residue Limit (MRL) for all the pesticides under study. The method was employed to analyze samples of Mikania laevigata, Maytenus ilicifolia and Cordia verbenacea from an experimental field in Paulínia, SP, Brazil. The samples presented contamination with dieldrin above the MRL established by the European Pharmacopoeia (50 ng g-1).
    2007 article Brazil open access
  8. 8

    Aspectos de legislação do mercado internacional de embalagens plásticas para alimentos

    Publication
    by Freire,Maria T. de A.
    Other Authors: Reyes,Felix G. R.; Kuznesof,Paul M.; Vettorazzi,Gaston
    Origin: Oasisbr
    RESUMO: Neste artigo de revisão são abordados aspectos de legislação relacionados ao uso seguro de componentes de materiais de embalagem plástica para alimentos. São apresentados os sistemas de regulamentação adotados no Brasil, Estados Unidos da América, União Européia e MERCOSUL.
    1998 article Brazil open access
  9. 9

    Deltamethrin and Permethrin in the liver and heart of Wistar rats submitted to oral subchronic exposure

    Publication
    by Santos,Mônica A. T
    Other Authors: Rodrigues,Marili V. N; Áreas,Miguel A; Reyes,Felix G. R
    Origin: Oasisbr
    For 28 days male Wistar rats were submitted to oral exposure with 1/10 of the LD50 value of permethrin (PMT) or deltamethrin (DMT). The aim of this study was to determine the residues of PMT and DMT in the liver and heart of the rats at the end of the exposure period, as well as to evaluate the effect of ingesting pectin and cellulose via the diet. The analytes were extracted with acetonitrile and the extracts were cleaned up by solid phase extraction with florisil before GC-ECD (gas chromatography coupled with an electron-capture detector) analysis. For PMT, the limits of quantitation (LOQ) were 1.0 and 0.2 µg g-1 and for DMT 0.9 and 0.2 µg g-1 for liver and heart, respectively. No PMT or DMT residues were verified above the LOQ of the method in either the liver or heart of the exposed animals
    2011 article Brazil open access
  10. 10

    Validação de métodos cromatográficos para a determinação de resíduos de medicamentos veterinários em alimentos

    Publication
    by Paschoal,Jonas Augusto Rizzato
    Other Authors: Rath,Susanne; Airoldi,Flavia Pereira da Silva; Reyes,Felix G. R.
    Origin: Oasisbr
    Different agencies that supply validation guidelines worldwide establish almost the same parameters to be evaluated in the validation process of bioanalytical methods. However, they recommend different procedures, as well as establish different acceptance criteria. The present review delineates and discusses the stages involved in the validation procedures of bioanalytical methods designed for determining veterinary residues in food, explaining the main differences in the guidelines established for this purpose by the main regulatory agencies in the world.
    2008 article Brazil open access