Resultados da pesquisa - "PTDC/AAG-MAA/5887/2014"

Catálogo de Publicações - "PTDC/AAG-MAA/5887/2014"

Filtros
  1. 1

    Sequential injection system with in-line solid phase mini-column extraction for zinc and copper determiantion

    Publicação
    por Paluch, Justyna
    Outros Autores: Mesquita, Raquel B. R.; Kosak, Joanna; Wierczorek, Marcin; Rangel, António O.S.S.
    2017 documento de conferência Portugal acesso aberto
  2. 2

    Evaluation of the impact of fertilizers on soil and soil leachates – chemical composition and microbial community assemblage

    Publicação
    por Costa, Carolina
    Outros Autores: Rocha, Filipa; Machado, A.; Mesquita, Raquel B. R.; Bordalo, Adriano A.; Rangel, António O. S. S.
    2017 documento de conferência Portugal acesso aberto
  3. 3
  4. 4

    Use of a polymer inclusion membrane and a chelating resin for the flow-based sequential determination of copper(II) and zinc(II) in natural waters and soil leachates

    Publicação
    por Ribas, Tânia C. F.
    Outros Autores: Croft, Charles F.; Almeida, M. Inês G. S.; Mesquita, Raquel B. R.; Kolev, Spas D.; Rangel, António O. S. S.
    A bi-parametric sequential injection method for the determination of copper(II) and zinc(II) when present together in aqueous samples was developed. This was achieved by using a non-specific colorimetric reagent (4-(2-pyridylazo)resorcinol, PAR) together with two ion-exchange polymeric materials to discriminate between the two metal ions. A polymer inclusion membrane (PIM) and a chelating resin (Chelex 100) were the chosen materials to retain zinc(II) and copper(II), respectively. The influence of the flow system parameters, such as composition of the reagent solutions, flow rates and standard/sample volume, on the method sensitivity were studied. The interference of several common metal ions was assessed, and no significant interferences were observed (<10% signal deviation). The limits of detection were 3.1 and 5.6 µg L−1 for copper(II) and zinc(II), respectively; the dynamic working range was from 10 to 40 µg L−1 for both analytes. The newly developed sequential injection analysis (SIA) system was applied to natural waters and soil leachates, and the results were in agreement with those obtained with the reference procedure.
    2020 artigo Portugal acesso aberto
  5. 5

    Assessment of the impact synthetic Fe(III)-chelates amendment in soil microbial community dynamics

    Publicação
    por Machado, Ana
    Outros Autores: Mesquita, Letícia S.; Rangel, Maria; Mesquita, Raquel B. R.; Rangel, António O. S. S.; Bordalo, Adriano A.
    2017 documento de conferência Portugal acesso aberto
  6. 6
  7. 7
  8. 8
  9. 9

    Soil/Water interface assessment using sequential injection for multiparametric analysis

    Publicação
    por Mesquita, Raquel B. R.
    Outros Autores: Costa, Carolina F. F. A.; Mesquita, Letícia S.; Rangel, António O.S.S.
    2017 documento de conferência Portugal acesso aberto
  10. 10