Resultados da pesquisa - "Oliveira, N."

Catálogo de Publicações - "Oliveira, N."

Filtros
  1. 1

    Bridging Thoracic Endovascular Aneurysm Repair for a Late Rupture Following Aortic Coarctation Angioplasty

    Publicação
    por Oliveira, N
    Outros Autores: Albuquerque e Castro, J; Martins, JD; Quintas, A; Laranjo, S; Valentim, H et al.
    Introduction Thoracic endovascular aneurysm repair has been employed to treat late complications after aortic coarctation correction. However, its use in children has seldomly been reported. Case report We present the case of a 15-year-old child who presented with a ruptured aneurysm of the descending aorta complicated later by an aortic-oesophageal fistula following aortic coarctation stenting that was managed with multiple bridging endovascular interventions until a definitive repair was performed.
    2016 artigo Portugal acesso aberto
  2. 2

    Predição de Pré-Eclâmpsia no Primeiro Trimestre em Gravidezes de Baixo Risco: Determinação do Cut-Off numa Amostra da População Portuguesa

    Publicação
    por Oliveira, N
    Outros Autores: Carrilho, B; Carocha, A; Martins, AT; Cohen, A; Martins, I et al.
    Objective:We aimed to identify the cut-off for risk of pre-eclampsia (PE) in Portuguese population by applying the first trimester prediction model from Fetal Medicine Foundation (FMF) in a prospective enrolled cohort of low risk pregnant women. Population and methods: A prospective cohort of low risk singleton pregnancies underwent routine first-trimester scree - ning from 2011 through 2013. Maternal characteristics, blood pressure, uterine artery Doppler, levels of pregnancy-associated plasma protein-A (PAPP-A) and free b-human chorionic gonadotropin were evaluated. The prediction of PE in first trimester was calculated through software Astraia, the outcome obtained from medical records and the cutoff value was subse quently calculated. Results:Of the 273 enrolled patients, 7 (2.6%) developed PE. In first trimester women who developed PE presented higher uterine arteries resistance, represented by higher values of lowest and mean uterine pulsatility index, p <0.005. There was no statistical significance among the remaining maternal characteristics, body mass index, blood pressure and PAPP-A. Using the FMF first trimester PE algorithm, an ideal cut-off of 0.045 (1/22) would correctly detect 71% women who developed PE for a 12% false positive rate and a likelihood ratio of 12.98 (area under the curve: 0.69; confidence interval 95%: 0.39-0.99). By applying the reported cutoff to our cohort, we would obtain 71.4% true positives, 88.3% true negatives, 11.4% false positives and 28.6% false negatives. Conclusion: By applying a first trimester PE prediction model to low risk pregnancies derived from a Portuguese population, a significant proportion of patients would have been predicted as high risk. New larger studies are required to confirm the present findings.
    2015 artigo Portugal acesso aberto
  3. 3

    Long-Term Outcomes of Standard Endovascular Aneurysm Repair in Patients With Severe Neck Angulation

    Publicação
    por Oliveira, N
    Outros Autores: Bastos Gonçalves, F; Hoeks, S; Josee van Rijn, M; Ultee, K; Pinto, JP et al.
    Objective: Severe neck angulation is associated with complications after endovascular aneurysm repair (EVAR). Newer endografts may overcome this limitation, but the literature lacks long-term results. We studied the long-term outcomes of EVAR in patients with severe neck angulation. Methods: A retrospective case-control study of a prospective multicenter database was performed. All measurements were made with dedicated software with center lumen line reconstruction. A study group including patients with neck length >15 mm, infrarenal angle (β) >75 degrees or suprarenal angle (α) >60 degrees, and neck length 10 to 15 mm with β >60 degrees or α >45 degrees was compared with a control group matched for demographics and other morphologic neck features. The primary end point was type IA endoleak (EL1A). Secondary end points were freedom from neck-related secondary interventions, primary clinical success, and overall survival. Results: Forty-five patients were included in the angulated neck group and compared with 65 matched patients. Median follow-up was 7.4 years (interquartile range, 4.8-8.5 years). In the angulated neck group, mean α was 51.4 degrees (±21.1 degrees) and the mean β was 80.8 degrees (±15.6 degrees); in the nonangulated group, these were 17.9 degrees (±17.0 degrees) and 35.4 degrees (±20.0 degrees), respectively. At 7 years, five patients in the angulated neck group and two nonangulated patients developed EL1A, yielding a freedom from EL1A of 86.1% (n = 14; standard error [SE], 0.069) and 96.6% (n = 34; SE, 0.023), respectively (P = .056). After exclusion of a patient who developed an EL1A secondary to an endograft infection, this difference was significant: 86.1% (n = 14; SE, 0.069) in the angulated neck group and 98.2% (n = 34; SE, 0.018) in the nonangulated group (P = .016). At 7 years, freedom from neck-related secondary interventions was 91.7% (n = 14; SE, 0.059) and 91.6% (n = 29; SE, 0.029), respectively. The 7-year primary clinical success estimates were 41.2% (n = 11; SE, 0.085) and 56.6% (n = 20; SE, 0.072) for the angulated neck and nonangulated groups, respectively (P = .12). The 7-year survival rates were 44.3% (n = 18; SE, 0.076) vs 66.7% (n = 42; SE, 0.059) for the angulated neck and nonangulated groups, respectively (P = .25). Device integrity failure was not observed. Conclusions: Despite satisfactory results early and in the midterm, a higher rate of EL1A was identified among patients with severely angulated necks in the long term. However, mortality was not affected by this difference. These findings suggest that EVAR should be used judiciously in patients with extreme angulation of the proximal neck and highlight the need for close follow-up of EVAR, especially in the long term and in patients treated outside instructions for use.
    2018 artigo Portugal acesso aberto
  4. 4

    Anatomic Predictors for Late Mortality after Standard Endovascular Aneurysm Repair

    Publicação
    por Oliveira, N
    Outros Autores: Ultee, K; van Rijn, MJ; Pinto, JP; Raa, S; Bastos Gonçalves, F et al.
    Objective: Abdominal aortic aneurysm (AAA) management involves a decision process that takes into account anatomic characteristics, surgical risks, patients' preferences, and expected survival. Whereas larger AAA diameter has been associated with increased mortality after both standard endovascular aneurysm repair (EVAR) and open repair, it is unclear whether survival after EVAR is influenced by other anatomic characteristics. The purpose of this study was to determine the importance of baseline anatomic features on survival after EVAR. Methods: All patients treated at a tertiary teaching center with EVAR for intact standard infrarenal AAA from 2000 to 2014 were included. The civil data registry was queried to determine survival status; causes of death were obtained from death certificates. The primary study end point was to determine the impact of baseline morphologic features on all-cause and cardiovascular mortality after EVAR. Results: This study included 404 EVAR patients (12.1% women; mean age, 73 years) with a median follow-up of 5.8 years (interquartile range, 3.1-7.4 years). The 5- and 10-year overall survival rates for the entire population after EVAR were 70% (95% confidence interval [CI], 66%-75%) and 43% (95% CI, 37%-50%), respectively. Only AAA diameter >70 mm (hazard ratio [HR], 1.75; 95% CI, 1.20-3.56) was identified as an independent anatomic predictor of all-cause mortality. Death due to cardiovascular causes occurred in 60 (38.5%) patients. Aneurysm-related mortality was responsible for six of the cardiovascular-related deaths. In multivariable analysis, both neck diameter ≥30 mm (HR, 2.16; 95% CI, 1.05-4.43) and AAA diameter >70 mm (HR, 2.45; 95% CI, 1.34-4.46) were identified as independent morphologic risk factors for cardiovascular mortality, whereas >25% circumferential neck thrombus (HR, 0.32; 95% CI, 0.13-0.77) was protective. Conclusions: This study suggests that patients with AAA diameters >70 mm are at increased risk of all-cause and cardiovascular mortality. In addition, patients with infrarenal neck diameters ≥30 mm have a greater risk of cardiovascular mortality, although AAA-related deaths were not more frequent in this group of patients. Consequently, a more aggressive management of cardiovascular medical comorbidities may be warranted to improve survival after standard EVAR in these patients.
    2019 artigo Portugal acesso aberto
  5. 5

    Risk Factors, Dynamics, and Clinical Consequences of Aortic Neck Dilatation after Standard Endovascular Aneurysm Repair

    Publicação
    por Oliveira, N
    Outros Autores: Oliveira-Pinto, J; Rijn, M; Baart, S; Raa, S; Hoeks, S et al.
    Objective: Aortic neck dilatation (AND) occurs after endovascular aneurysm repair (EVAR) with self expanding stent grafts (SESs). Whether it continues, ultimately exceeding the endograft diameter leading to abdominal aortic aneurysm (AAA) rupture, remains uncertain. Dynamics, risk factors, and clinical relevance of AND were investigated after EVAR with standard SESs. Methods: All intact EVAR patients treated from 2000 to 2015 at a tertiary institution were included. Demographic, anatomical, and device related characteristics were investigated as risk factors for AND. Outer to outer diameters were measured at a single standardised aortic level on reconstructed computed tomography (CT) images. Results: A total of 460 patients were included (median follow up 5.2 years, interquartile range [IQR] 3.0, 7.7 years; CT imaging follow up 3.3 years, IQR 1.3, 5.4). Baseline neck diameter was 24 mm (IQR 22, 26) and increased 11.1% (IQR 1.5%, 21.9%) at last CT imaging. Endograft oversizing was 20.0% (IQR 13.6, 28.0). AND was greater during the first year (5.2% [IQR 0, 11.7]) decreasing subsequently (two to four years to 1.4%/year [IQR 0.0, 4.5%], p ≤ .001) and was associated with suprarenal fixation endografts (t value = 7.9, p < .001) and oversizing (t value = 4.4, p < .001). AND exceeding the endograft was 3.5% (95% CI 2.2% - 4.8%) and 14.4% (95% CI 11.0% - 17.8%) at five and eight years, respectively. Excessive AND was associated with baseline neck diameter (OR 1.2/mm, 95% CI 1.05 - 1.41) while the Excluder endograft had a protective effect (OR 0.15, 95% CI 0.04 - 0.58). Excessive AND was associated with type 1A endoleak (HR 3.3, 95% CI 1.1 - 9.7) and endograft migration > 5 mm (HR 3.1, 95% CI 1.4 - 6.9). Conclusion: AND after EVAR with SES is associated with endograft oversizing and radial force but decelerates after the first post-operative year. Baseline aortic neck diameter and suprarenal stent bearing endografts were associated with an increased risk of AND beyond nominal stent graft diameter. However, it remains unclear whether patient selection, differences in endograft radial force or the suprarenal stent are accountable for this difference.
    2021 artigo Portugal acesso aberto
  6. 6

    Levonorgestrel Intrauterine Device Effectiveness in Heavy Menstrual Bleeding Treatment in Obese Women

    Publicação
    por Oliveira, N
    Outros Autores: Rosado, V; Correia, L; Machado, AI; Marques, C
    Objective:We aimed to identify if there was any difference in Levonorgestrel-releasing intrauterine system (LNG-IUS) efficacy or weight gain when used in heavy menstrual bleeding (HMB) treatment, between obese and non-obese women. Population and methods: This was a case-controlled retrospective study undertaken between 2002-2007. 194 women with HMB were treated with LNG-IUS and stratified into two groups accordingly with body mass index (BMI): Obese Group – BMI ≥ 30 (n=53) and Non-obese Group – BMI < 30 (n=141). Age, weight, days of spotting and days of menses were analyzed at 1, 3 and 6 months after insertion and then annually until 2 years. Analytic parameters of anemia (hemoglobin, serum ferritin, mean corpuscular volume) were reviewed at pre-insertion, at 6 months and then annually until 2 years. Results: During the 2-year follow-up there was a similar improvement in two groups regarding duration of menses, spotting and in analytic parameters of anemia. A statistically significant improvement was observed in obese group after 2 years of treatment regarding analytic parameters of anemia and menstrual characteristics, without weight gain. Conclusion: In obese women, the LNG-IUS is an effective treatment for heavy menstrual bleeding, without being associated to weight gain.
    2014 artigo Portugal acesso aberto
  7. 7

    Patients with Large Neck Diameter Have a Higher Risk of Type IA Endoleaks and Aneurysm Rupture after Standard Endovascular Aneurysm Repair

    Publicação
    por Oliveira, N
    Outros Autores: Bastos Gonçalves, F; Ultee, K; Pinto, JP; Rijn, MJ; Raa, S et al.
    Objective: Standard endovascular aneurysm repair (EVAR) is the most common treatment of abdominal aortic aneurysms (AAAs). EVAR has been increasingly used in patients with hostile neck features. This study investigated the outcomes of EVAR in patients with neck diameters ≥30 mm in the prospectively maintained Endurant Stent Graft Natural Selection Global Postmarket Registry (ENGAGE). Methods: This is a retrospective study comparing patients with neck diameters ≥30 mm with patients with neck diameters <30 mm. The primary end point was type IA endoleak (EL1A). Secondary end points included secondary interventions to correct EL1A, aneurysm rupture, and survival. Results: This study included 1257 patients (mean age, 73.1 years; 89.4% male) observed for a median 4.0 years (interquartile range, 2.7-4.8 years). A total of 97 (7.7%) patients had infrarenal neck diameters ≥30 mm and were compared with the remaining 1160 (92.3%) with neck diameters <30 mm. At baseline, there were no differences between groups regarding demographics and comorbidities other than cardiac disease, which was more frequent in the ≥30-mm neck diameter group (P = .037). There were no significant differences between the groups regarding neck length, angulation, thrombus, or calcification. Mean preoperative AAA diameter was 64.6 ± 11.3 mm in the ≥30-mm neck diameter group and 60.0 ± 11.6 mm in the <30-mm neck diameter group (P < .001). Stent graft oversizing was significantly less in the ≥30-mm neck diameter group (12.2% ± 8.9% vs 22.1% ± 11.9%; P <. 001). Five patients (5.2%) in the ≥30-mm neck diameter group and 30 (2.6%) with neck diameters <30 mm developed EL1A, yielding a 4-year freedom from EL1A of 92.4% vs 96.6%, respectively (P = .09). Oversizing was 21.8% ± 13.0% for patients developing EL1A and 21.3% ± 12.4% for the remaining cohort (P = .99). In adjusting for neck length, AAA diameter, and device oversizing, patients with neck diameter ≥30 mm were at greater risk for development of EL1A (hazard ratio, 3.0; 95% confidence interval, 1.0-9.3; P = .05). Secondary interventions due to EL1A did not differ between groups (P = .36). AAA rupture occurred in three patients with neck diameter ≥30 mm (3.1%) and in eight patients with neck diameter <30 mm (0.7%; hazard ratio, 5.1; 95% confidence interval, 1.4-19.2; P = .016); two cases were EL1A related in each group. At 4 years, overall survival was 61.6% for the ≥30-mm neck diameter group and 75.2% for the <30-mm neck diameter group (P = .009), which remained significant on correcting for sex and AAA diameter (P = .016). Conclusions: In this study, patients with infrarenal neck diameter ≥30 mm had a threefold increased risk of EL1A and fivefold risk of aneurysm rupture after EVAR as well as worse overall survival. This may influence the choice of AAA repair and underlines the need for regular computed tomography-based imaging surveillance in this subset of patients. Furthermore, these results can serve as standards with which new, possibly improved technology, such as EndoAnchors (Medtronic, Santa Rosa, Calif), can be compared.
    2019 artigo Portugal acesso aberto
  8. 8

    Clinical Outcome and Morphologic Determinants of Mural Thrombus in Abdominal Aortic Endografts

    Publicação
    por Oliveira, N
    Outros Autores: Bastos Gonçalves, F; Hoeks, S; Ten Raa, S; Ultee, K; Rouwet, E et al.
    OBJECTIVE:Endograft mural thrombus has been associated with stent graft or limb thrombosis after endovascular aneurysm repair (EVAR). This study aimed to identify clinical and morphologic determinants of endograft mural thrombus accumulation and its influence on thromboembolic events after EVAR. METHODS: A prospectively maintained database of patients treated by EVAR at a tertiary institution from 2000 to 2012 was analyzed. Patients treated for degenerative infrarenal abdominal aortic aneurysms and with available imaging for thrombus analysis were considered. All measurements were performed on three-dimensional center-lumen line computed tomography angiography (CTA) reconstructions. Patients with thrombus accumulation within the endograft's main body with a thickness >2 mm and an extension >25% of the main body's circumference were included in the study group and compared with a control group that included all remaining patients. Clinical and morphologic variables were assessed for association with significant thrombus accumulation within the endograft's main body by multivariate regression analysis. Estimates for freedom from thromboembolic events were obtained by Kaplan-Meier plots. RESULTS: Sixty-eight patients (16.4%) presented with endograft mural thrombus. Median follow-up time was 3.54 years (interquartile range, 1.99-5.47 years). In-graft mural thrombus was identified on 30-day CTA in 22 patients (32.4% of the study group), on 6-month CTA in 8 patients (11.8%), and on 1-year CTA in 17 patients (25%). Intraprosthetic thrombus progressively accumulated during the study period in 40 patients of the study group (55.8%). Overall, 17 patients (4.1%) presented with endograft or limb occlusions, 3 (4.4%) in the thrombus group and 14 (4.1%) in the control group (P = .89). Thirty-one patients (7.5%) received an aortouni-iliac (AUI) endograft. Two endograft occlusions were identified among AUI devices (6.5%; overall, 0.5%). None of these patients showed thrombotic deposits in the main body, nor were any outflow abnormalities identified on the immediately preceding CTA. Estimated freedom from thromboembolic events at 5 years was 95% in both groups (P = .97). Endograft thrombus accumulation was associated with >25% proximal aneurysm neck thrombus coverage at baseline (odds ratio [OR], 1.9; 95% confidence interval [CI], 1.1-3.3), neck length ≤ 15 mm (OR, 2.4; 95% CI, 1.3-4.2), proximal neck diameter ≥ 30 mm (OR, 2.4; 95% CI, 1.3-4.6), AUI (OR, 2.2; 95% CI, 1.8-5.5), or polyester-covered stent grafts (OR, 4.0; 95% CI, 2.2-7.3) and with main component "barrel-like" configuration (OR, 6.9; 95% CI, 1.7-28.3). CONCLUSIONS: Mural thrombus formation within the main body of the endograft is related to different endograft configurations, main body geometry, and device fabric but appears to have no association with the occurrence of thromboembolic events over time.
    2015 artigo Portugal acesso aberto
  9. 9

    Genotoxic effects of boron neutron capture reaction in human melanoma cells

    Publicação
    por Oliveira, N
    Outros Autores: Castro, M; Rodrigues, AS; Gonçalves, IC; Cassapo, R; Fernandes, AP et al.
    2000 artigo Portugal
  10. 10

    Prótese no Delgado

    Publicação
    por Oliveira, N
    Outros Autores: Morgado, M; Carvalho, P; Queimado, H; Ramos, L; Rodrigues, F
    2016 documento de conferência Portugal acesso aberto