Resultados da pesquisa - "Idzik, M."

Pesquisas alternativas:

Catálogo de Publicações - "Idzik, M."

  • A mostrar 1 - 4 resultados de 4
Filtros
  1. 1

    Observation of the rare B-s(0)->mu(+)mu(-) decay from the combined analysis of CMS and LHCb data

    Publicação
    por Khachatryan, V.
    Outros Autores: Sirunyan, A. M.; Tumasyan, A.; Adam, W.; Bergauer, T.; Dragicevic, M. et al.
    Origem: Oasisbr
    Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
    2015 artigo Brasil acesso aberto
  2. 2

    TOFHIR2

    Publicação
    por Albuquerque, E.
    Outros Autores: Araújo, M.; Benaglia, A.; Boletti, A.; Bugalho, R.; Coutinho, T. et al.
    The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.5 Mhit/s per channel is expected along the HL-LHC lifetime. We present an overview of the TOFHIR2 requirements and design, simulation results and measurements with TOFHIR2 ASICs. The measurements of TOFHIR2 associated to sensor modules were performed in different test setups using internal test pulses or blue and UV laser pulses emulating the signals expected in the experiment. The measurements show a time resolution of 24 ps initially during Beginning of Operation (BoO) and 58 ps at End of Operation (EoO) conditions, matching well the BTL requirements. We also showed that the time resolution is stable up to the highest expected MIP rate. Extensive radiation tests were performed, both with x-rays and heavy ions, showing that TOFHIR2 is not affected by the radiation environment during the experiment lifetime.
    2024 artigo Portugal acesso aberto
  3. 3

    The dependence of the anomalous J/psi suppression on the number of participant nucleons

    Publicação
    por M. C. Abreu
    Outros Autores: Alessandro, B.; Alexa, C.; Arnaldi, R.; Atayan, M.; Baglin, C. et al.
    The observation of an anomalous J/psi suppression in Pb-Pb collisions by the NA50 Collaboration can be considered as the most striking indication for the deconfinement of quarks and gluons at SPS energies. In this Letter, we determine the J/psi suppression pattern as a function of the forward hadronic energy E-ZDC measured in a Zero Degree Calorimeter (ZDC). The direct connection between EZDC and the geometry of the collision allows us to calculate, within a Glauber approach, the precise relation between the number of participant nucleons N-part and E-ZDC. Then, we check if the experimental data can be better explained by a sudden or a smooth onset of the anomalous J/psi suppression as a function of the number of participants. (C) 2001 Elsevier Science B.V. All rights reserved.
    2001 artigo Portugal acesso aberto
  4. 4

    Silicon strip detectors for two-dimensional soft X-ray imaging at normal incidence

    Publicação
    por Mendes, PR
    Outros Autores: Abreu, MC; Baldazzi, G; Bollini, D; Rodriguez, AEC; Dabrowski, W et al.
    A simple prototype system for static two-dimensional soft X-ray imaging using silicon microstrip detectors irradiated at normal incidence is presented. Radiation sensors consist of single-sided silicon detectors made from 300 mum thick wafers, read by RX64 ASICs. Data acquisition and control is performed by a Windows PC workstation running dedicated LabVIEW routines, connected to the sensors through a PCI-DIO-96 interface. Two-dimensional images are obtained by scanning a lead collimator with a thin slit perpendicular to the strip axis, along the whole detector size; the several strip profiles (slices) taken at each position are then put together to form a planar image. Preliminary results are presented, illustrating the high-resolution imaging capabilities of the system with soft X-rays. (C) 2003 Elsevier B.V. All rights reserved.
    2003 artigo Portugal acesso aberto