Search Results - "Bozukova, Dimitriya"

Publication Catalog - "Bozukova, Dimitriya"

  • Showing 1 - 8 results of 8
Refine Results
  1. 1

    Sterilization of ophthalmic drugs and intraocular lenses

    Publication
    by Oliveira, Andreia
    Other Authors: Moutinho, Guilhermina M.; Bozukova, Dimitriya; Saramago, Benilde; Serro, A. P.
    2015 conference output Portugal open access
  2. 2

    Effect of sterilization on drugs and lenses for ophthalmic applications

    Publication
    by Topete, Ana
    Other Authors: Oliveira, Andreia; Galante, Raquel; Bozukova, Dimitriya; Saramago, Benilde; Serro, A. P.
    2016 conference output Portugal open access
  3. 3

    Sterilization of intraocular lenses loaded with moxifloxacin

    Publication
    by Filipe, Helena P.
    Other Authors: Oliveira, Andreia; Moutinho, M. Guilhermina; Bozukova, Dimitriya; Saramago, Benilde; Serro, A. P.
    2016 conference output Portugal open access
  4. 4

    Chitosan/alginate based multilayers to control drug release fromophthalmic lens

    Publication
    by Silva, Diana
    Other Authors: Pinto, Luís F. V.; Bozukova, Dimitriya; Santos, Luís F.; Serro, Ana Paula; Saramago, Benilde
    In this study we investigated the possibility of using layer-by-layer deposition, based in natural polymers (chitosan and alginate), to control the release of different ophthalmic drugs from three types of lens materials: a silicone-based hydrogel recently proposed by our group as drug releasing soft contact lens (SCL) material and two commercially available materials: CI26Y for intraocular lens (IOLs) and Definitive 50 for SCLs. The optimised coating, consisting in one double layer of (alginate – CaCl2)/(chitosan + glyoxal) topped with a final alginate-CaCl2 layer to avoid chitosan degradation by tear fluid proteins, proved to have excellent features to control the release of the anti-inflammatory, diclofenac, while keeping or improving the physical properties of the lenses. The coating leads to a controlled release of diclofenac from SCL and IOL materials for, at least, one week. Due to its high hydrophilicity (water contact angle ≈ 0) and biocompatibility, it should avoid the use of further surface treatments to enhance the useŕs comfort. However, the barrier effect of this coating is specific for diclofenac, giving evidence to the need of optimizing the chemical composition of the layers in view of the desired drug.
    2016 article Portugal open access
  5. 5

    Diclofenac release from a silicon based contact lens material controlled by a chitosan/alginate coating

    Publication
    by Filipe, Helena
    Other Authors: Silva, Diana; Pinto, Luís F. V.; Henriques, José; Bozukova, Dimitriya; Saramago, Benilde et al.
    2016 conference output Portugal open access
  6. 6

    Surface modification of an intraocular lens material by plasma-assisted grafting with 2-hydroxyethyl methacrylate (HEMA), for controlled release of moxifloxacin

    Publication
    by Vieira, Ana Paula
    Other Authors: Pimenta, Andreia; Silva, Diana; Gil, Maria; Alves, Patrícia; Coimbra, Patrícia et al.
    Origin: uBibliorum
    Endophthalmitis, an inflammation of the eye due to perioperative infection, may occur after cataract surgery. Intraocular lenses (IOLs) loaded with an antibiotic have been proposed as an alternative to the conventional postoperative endophthalmitis prophylaxis, since the antibiotic is delivered directly to the target site. In this work, an IOL-based antibiotic releasing system was prepared from a copolymer used in the production of IOLs and a fluoroquinolone used in endophthalmitis prophylaxis (moxifloxacin, MFX). Argon plasma-assisted grafting with 2-hydroxyethyl methacrylate (HEMA) in the presence of MFX was the approach selected for surface modification, with MFX loaded both by entrapment in the grafted polyHEMA coating and by soaking. Surface and bulk properties were evaluated before and after surface modification and the MFX release profiles were obtained both in batch mode (sink conditions) and under hydrodynamic conditions, employing a purpose-built microfluidic cell, which simulated the hydrodynamic conditions around the eye lens. The effect of storage on the release profile of the best system was also assessed. The best system released MFX for ca. 15 days above the minimum inhibitory concentration for Staphylococcus aureus and Staphylococcus epidermidis. The released MFX showed antimicrobial activity against these bacteria and was non-cytotoxic against corneal endothelial cells.
    2017 article Portugal restricted access
  7. 7

    Controlled release of moxifloxacin from intraocular lenses modified by Ar plasma-assisted grafting with AMPS or SBMA: An in vitro study

    Publication
    by Pimenta, Andreia
    Other Authors: Vieira, Ana Paula; Colaco, Rogério; Saramago, Benilde; Gil, Maria; Coimbra, Patrícia et al.
    Origin: uBibliorum
    Intraocular lenses (IOLs) present an alternative for extended, local drug delivery in the prevention of post-operative acute endophthalmitis. In the present work, we modified the surface of a hydrophilic acrylic material, used for manufacturing of IOLs, through plasma-assisted grafting copolymerization of 2-acrylamido-2-methylpropane sulfonic acid (AMPS) or [2-(methacryloyloxy)ethyl]dimethyl-(3-sulfopropyl)ammonium hydroxide (SBMA), with the aim of achieving a controlled and effective drug release. The material was loaded with moxifloxacin (MFX), a commonly used antibiotic for endophthalmitis prevention. The characterization of the modified material showed that relevant properties, like swelling capacity, wettability, refractive index and transmittance, were not affected by the surface modification. Concerning the drug release profiles, the most promising result was obtained when AMPS grafting was done in the presence of MFX. This modification led to a higher amount of drug being released for a longer period of time, which is a requirement for the prevention of endophthalmitis. The material was found to be non-cytotoxic for rabbit corneal endothelial cells. In a second step, prototype IOLs were modified with AMPS and loaded with MFX as previously and, after sterilization and storage (30 days), they were tested under dynamic conditions, in a microfluidic cell with volume and renovation rate similar to the eye aqueous humour. MFX solutions collected in this assay were tested against Staphylococcus aureus and Staphylococcus epidermidis and the released antibiotic proved to be effective against both bacteria until the 12th day of release.
    2017 article Portugal restricted access
  8. 8

    Surface modification of an intraocular lens material by plasma-assisted grafting with 2- hydroxyethyl methacrylate (HEMA), for controlled release of moxifloxacin

    Publication
    by Vieira, A. Paula
    Other Authors: Pimenta, Andreia F. R.; Silva, Diana; Gil, M. Helena; Alves, Patrícia; Coimbra, Patrícia et al.
    Endophthalmitis, an inflammation of the eye due to perioperative infection, may occur after cataract surgery. Intraocular lenses (IOLs) loaded with an antibiotic have been proposed as an alternative to the conventional postoperative endophthalmitis prophylaxis, since the antibiotic is delivered directly to the target site. In this work, an IOL-based antibiotic releasing system was prepared from a copolymer used in the production of IOLs and a fluoroquinolone used in endophthalmitis prophylaxis (moxifloxacin, MFX). Argon plasma-assisted grafting with 2- hydroxyethyl methacrylate (HEMA) in the presence of MFX was the approach selected for surface modification, with MFX loaded both by entrapment in the grafted polyHEMA coating and by soaking. Surface and bulk properties were evaluated before and after surface modification and the MFX release profiles were obtained both in batch mode (sink conditions) and under hydrodynamic conditions, employing a purpose-built microfluidic cell, which simulated the hydrodynamic conditions around the eye lens. The effect of storage on the release profile of the best system was also assessed. The best system released MFX for ca. 15 days above the minimum inhibitory concentration for Staphylococcus aureus and Staphylococcus epidermidis. The released MFX showed antimicrobial activity against these bacteria and was non-cytotoxic against corneal endothelial cells.
    2017 article Portugal open access