Search Results - "Barroso,M. Fátima"

Search alternatives:

Publication Catalog - "Barroso,M. Fátima"

Refine Results
  1. 1

    Cathodic Behaviour of Cysteine at a Platinum Electrode

    Publication
    by Barroso,M. Fátima
    Other Authors: Santos,Teresa; Sales,M. Goreti F.; Delerue-Matos,Cristina; Vaz,M. Carmo V. F.
    Origin: SciELO Portugal
    The electroreduction behaviour of cysteine was investigated using cyclic, square wave and differencial pulse voltammetric techniques at a platinum working electrode. The reduction of cysteine occurs at a potential of -0.36 V independent of pH. It is a reversible process, controlled mainly by diffusion and in the mechanism of reduction 1 electron per molecule is involved. Using the voltammetric techniques: Cyclic Voltammetry, Square Wave Voltammetry and Differencial Pulse Voltammetry, different parameters (pH, frequency, step potential, pulse amplitude, scan rate) were optimized in order to develop an electrochemical procedure for determination of cysteine in pharmaceutical products. The repeatability, reproducibility, precision and accuracy of the methods were studied. No electroactive interferences from the excipient were found in the pharmaceutical compounds.
    2007 article Portugal open access
  2. 2

    Towards a reliable technology for antioxidant capacity and oxidative damage evaluation: Electrochemical (bio)sensors

    Publication
    by Barroso, M. Fátima
    Other Authors: de-los-Santos-Álvarez, N.; Delerue-Matos, Cristina; Oliveira, M. Beatriz P. P.
    To counteract and prevent the deleterious effect of free radicals the living organisms have developed complex endogenous and exogenous antioxidant systems. Several analytical methodologies have been proposed in order to quantify antioxidants in food, beverages and biological fluids. This paper revises the electroanalytical approaches developed for the assessment of the total or individual antioxidant capacity. Four electrochemical sensing approaches have been identified, based on the direct electrochemical detection of antioxidant at bare or chemically modified electrodes, and using enzymatic and DNA-based biosensors.
    2011 article Portugal open access
  3. 3

    Total antioxidant capacity of plant infusions: Assessment using electrochemical DNA-based biosensor and spectrophotometric methods

    Publication
    by Barroso, M. Fátima
    Other Authors: Ramalhosa, Maria João; Alves, Rita C.; Dias, Alexandra; Soares, Cristina M. D.; Oliva-Teles, M. Teresa et al.
    Nine plant infusions were assessed in terms of their polyphenolic compounds and antioxidant capacity properties by performing a “battery” of assays. Bioactive compounds (total phenolic and flavonoid content) were measured using spectrophotometric procedures and the total antioxidant capacity was determined by DPPHradical dot-RSA, FRAP and DNA-based biosensor against the reactive oxygen species: HOradical dot and H2O2. Although the optical methods are based on the donation of hydrogen or electrons between antioxidants and radicals, the DNA-based biosensor intends to simulate an in vivo assay by exposing DNA layer to biological ROS and antioxidants. In general, green and black tea showed higher polyphenolic content and antioxidant capacity evaluated by the described methods. All the analysed plant beverages showed to be a good source of bioactive compounds, particularly the green and black tea, peppermint and senna.
    2016 article Portugal restricted access
  4. 4

    DNA-based biosensor for the electrocatalytic determination of antioxidant capacity in beverages

    Publication
    by Barroso, M. Fátima
    Other Authors: de-los-Santos-Álvarez, N.; Lobo-Castañón, M. J.; Miranda-Ordieres, A. J.; Delerue-Matos, Cristina; Oliveira, M. Beatriz P. P. et al.
    Reactive oxygen species (ROS) are produced as a consequence of normal aerobic metabolism and are able to induce DNA oxidative damage. At the cellular level, the evaluation of the protective effect of antioxidants can be achieved by examining the integrity of the DNA nucleobases using electrochemical techniques. Herein, the use of an adenine-rich oligonucleotide (dA21) adsorbed on carbon paste electrodes for the assessment of the antioxidant capacity is proposed. The method was based on the partial damage of a DNA layer adsorbed on the electrode surface by OH• radicals generated by Fenton reaction and the subsequent electrochemical oxidation of the intact adenine bases to generate an oxidation product that was able to catalyze the oxidation of NADH. The presence of antioxidant compounds scavenged hydroxyl radicals leaving more adenines unoxidized, and thus, increasing the electrocatalytic current of NADHmeasured by differential pulse voltammetry (DPV). Using ascorbic acid (AA) as a model antioxidant species, the detection of as low as 50nMof AA in aqueous solution was possible. The protection efficiency was evaluated for several antioxidant compounds. The biosensor was applied to the determination of the total antioxidant capacity (TAC) in beverages.
    2011 article Portugal open access
  5. 5

    Flavoured versus natural waters: macromineral (Ca, Mg, K, Na) and micromineral (Fe, Cu, Zn) contents

    Publication
    by Barroso, M. Fátima
    Other Authors: Silva, Aurora; Ramos, Sandra; Oliva-Teles, Maria Teresa; Delerue-Matos, Cristina; Sales, M. Goreti F. et al.
    Macro (Ca, Mg, K, Na) and micromineral (Fe, Zn, Cu) composition of 39 waters was analysed. Determinations were made by atomic flame spectrophotometry for macrominerals and electrothermic atomisation in graphite furnace for microminerals. Mineral contents of still or sparkling natural waters (without flavours) changed from brand to brand. Mann–Whitney test was used to search for significant differences between flavoured and natural waters. For that, the concentration of each mineral was compared to the presence of flavours, preservatives, acidifying agents, fruit juice and/or sweeteners, according to the labelled composition. The statistical study demonstrated that flavoured waters generally have increased contents of K, Na, Fe and Cu. The added preservatives also led to significant differences in the mineral composition. Acidifying agents and fruit juice can also be correlated to the increase of Mg, K, Na, Fe and Cu. Sweeteners do not provide any significant difference in Ca, Mg, Fe and Zn contents.
    2009 article Portugal open access
  6. 6

    Electroanalytical study of the pesticide ethiofencarb

    Publication
    by Barroso, M. Fátima
    Other Authors: Vaz, M. Carmo V. F.; Sales, M. Goreti F.; Paíga, Paula; Delerue-Matos, Cristina
    A detailed study of voltammetric behavior of ethiofencarb (ETF) is reported using glassy carbon electrode (GCE) and hanging mercury drop electrode (HMDE). With GCE, it is possible to verify that the oxidative mechanism is irreversible, independent of pH, and the maximum intensity current was observed at +1.20 V vs. AgCl/Ag at pH 1.9. A linear calibration line was obtained from 1.0x10-4 to 8.0x10-4 mol L-1 with SWV method. To complete the electrochemical knowledge of ETF pesticide, the reduction was also explored with HMDE. A well-defined peak was observed at –1.00V vs. AgCl/Ag in a large range of pH with higher signal at pH 7.0. Linearity was obtained in 4.2x10-6 and 9.4x10-6 mol L-1 ETF concentration range. An immediate alkaline hydrolysis of ETF was executed, producing a phenolic compound (2-ethylthiomethylphenol) (EMP), and the electrochemical activity of the product was examined. It was deduced that it is oxidized on GCE at +0.75V vs. AgCl/Ag with a maximum peak intensity current at pH 3.2, but the compound had no reduction activity on HMDE. Using the decrease of potential peak, a flow injection analysis (FIA) system was developed connected to an amperometric detector, enabling the determination of EMP over concentration range of 1.0x10-7 and 1.0x10-5 mol L-1 at a sampling rate of 60 h-1. The results provided by FIA methodology were performed by comparison with results from high-performance liquid chromatography (HPLC) technique and demonstrated good agreement with relative deviations lower than 4%. Recovery trials were performed and the obtained values were between 98 and 104%.
    2006 article Portugal open access
  7. 7

    Survey of trace elements (Al, As, Cd, Cr, Co, Hg, Mn, Ni, Pb, Se, and Si) in retail samples of flavoured and bottled waters

    Publication
    by Barroso, M. Fátima
    Other Authors: Ramos, Sandra; Oliva-Teles, Maria Teresa; Delerue-Matos, Cristina; Sales, M. Goreti F.; Oliveira, M. Beatriz P. P.
    Concentrations of eleven trace elements (Al, As, Cd, Cr, Co, Hg, Mn, Ni, Pb, Se, and Si) were measured in 39 (natural and flavoured) water samples. Determinations were performed using graphite furnace electrothermetry for almost all elements (Al, As, Cd, Cr, Co, Mn, Ni, Pb, and Si). For Se determination hydride generation was used, and cold vapour generation for Hg. These techniques were coupled to atomic absorption spectrophotometry. The trace element content of still or sparkling natural waters changed from brand to brand. Significant differences between natural still and natural sparkling waters (p<0.001) were only apparent for Mn. The Mann–Whitney U-test was used to search for significant differences between flavoured and natural waters. The concentration of each element was compared with the presence of flavours, preservatives, acidifying agents, fruit juice and/or sweeteners, according to the labelled composition. It was shown that flavoured waters generally increase the trace element content. The addition of preservatives and acidifying regulators had a significant influence on Mn, Co, As and Si contents (p<0.05). Fruit juice can also be correlated to the increase of Co and As. Sweeteners did not provide any significant difference in Mn, Co, Se and Si content.
    2009 article Portugal open access
  8. 8

    Can Luminol Be a Fluorophore?

    Publication
    by Barroso, M. Fátima
    Other Authors: Silva, Rui J. A.; Moreira, Sérgio F.; Rodrigues, Sofia S.; Gonçalves, Helena M. R.; Duarte, Abel J.
    In this work, we report a new chemiluminescence system using bis-(2,4,6-trichlorophenyl) oxalate (TCPO) with hydrogen peroxide and luminol as fluorophore. The intense chemiluminescence reaction here described was fully investigated and it was determined that this fluorescent system has two strong light emissions at 440 and 490 nm, respectively. This new, user friendly, intense and striking light emission chemiluminescence system can be used as a very usefull tool for the design and construction of fluorescencent chemical sensors.
    2019 article Portugal open access
  9. 9

    Evaluation of the total antioxidant capacity of flavored water and electrochemical purine damage by sulfate radicals using a purine-based sensor

    Publication
    by Barroso, M. Fátima
    Other Authors: Delerue-Matos, Cristina; Oliveira, M. Beatriz P. P.
    In this study, a method for the electrochemical quantification of the total antioxidant capacity (TAC) in beverages was developed. The method is based on the oxidative damage to the purine bases, adenine or guanine, that are immobilized on a glassy carbon electrode (GCE) surface. The oxidative lesions on the DNA bases were promoted by the sulfate radical generated by the persulfate/iron(II) system. The presence of antioxidants on the reactive system promoted the protection of the DNA bases immobilized on the GCE by scavenging the sulfate radical. Square-wave voltammetry (SWV) was the electrochemical technique used to perform this study. The efficiencies of five antioxidants (ascorbic acid, gallic acid, caffeic acid, coumaric acid and resveratrol) in scavenging the sulfate radical and, therefore, their ability to protect the purine bases immobilized on the GCE were investigated. These results demonstrated that the purine-based biosensor is suitable for the rapid assessment of the TAC in flavors and flavored water.
    2011 article Portugal open access
  10. 10

    3D-nanostructured Au electrodes for the event-specific detection of MON810 transgenic maize

    Publication
    by Barroso, M. Fátima
    Other Authors: Freitas, Maria; Oliveira, M. Beatriz P.P.; de-los-Santos-Álvarez, Noemí; Lobo-Castañón, María Jesús; Delerue-Matos, Cristina
    In the present work, the development of a genosensor for the event-specific detection of MON810 transgenic maize is proposed. Taking advantage of nanostructuration, a cost-effective three dimensional electrode was fabricated and a ternary monolayer containing a dithiol, a monothiol and the thiolated capture probe was optimized to minimize the unspecific signals. A sandwich format assay was selected as a way of precluding inefficient hybridization associated with stable secondary target structures. A comparison between the analytical performance of the Au nanostructured electrodes and commercially available screen-printed electrodes highlighted the superior performance of the nanostructured ones. Finally, the genosensor was effectively applied to detect the transgenic sequence in real samples, showing its potential for future quantitative analysis.
    2015 article Portugal open access