Search Results

Publication Catalog - All

  • Showing 1 - 5 results of 5
Refine Results
  1. 1

    Pulp Temperature Rise Induced by Light-Emitting Diode Light-Curing Units Using an Ex Vivo Model

    Publication
    by Vinagre, Alexandra
    Other Authors: Ramos, João C.; Rebelo, Clara; Basto, José Francisco; Messias, Ana; Alberto, Nélia et al.
    The aim of this research was to compare the pulp temperature (PT) rise induced by four light-emitting diode light-curing units (LED LCUs) (Bluephase 20i, Demi Ultra, SPEC 3, and Valo) in different curing modes. Immediately after extraction, the pulp chamber of 11 premolars was accessed from the palatal cervical third of the crown for insertion of fiber Bragg grating (FBG) sensors for temperature measurement and kept in a 37.0° water bath. The teeth were then submitted to a random sequence of curing modes with four irradiations at 30 s intervals. Care was taken to ensure complete pulp temperature reset between curing modes. The curing modes were classified as high-energy (above 80 J/cm²) or low-energy (below 40 J/cm²) according to the total energy density delivered. Statistical analysis was performed with repeated ANOVA measures and Pearson's correlation for the association between energy density and temperature variation. The significance level was set to 0.05. All curing units promoted a statistically significant PT rise (p < 0.01). After four emissions, the PT rise was higher than 5.0 °C for the high-energy curing modes. The low-energy modes induced approximately a 2.5 °C rise. A strong positive correlation was found between energy density and PT increase (R = 0.715; p = 0.01). Exposure of intact premolars to LED LCUs induced significant and cumulative PT rise. Curing modes emitting high energy densities produced higher PT variations. Radiant exposure was positively correlated to PT variation.
    2019 article Portugal open access
  2. 2

    Polymerization Shrinkage Evaluation of Restorative Resin-Based Composites Using Fiber Bragg Grating Sensors

    Publication
    by Lins, Rodrigo
    Other Authors: Vinagre, Alexandra; Alberto, Nélia; Domingues, Maria F.; Messias, Ana; Martins, Luís R. et al.
    The purpose of this study was to compare the linear polymerization shrinkage of different restorative resin-based composites (RBCs) using fiber Bragg grating (FBG) sensors. Five RBCs were evaluated: Zirconfill® (ZFL); Aura Bulk-Fill (ABF); Tetric® N-Ceram Bulk-Fill (TBF); FiltekTM Bulk-Fill (FBF); and Admira Fusion-Ormocer® (ADF). Ten samples per resin were produced in standardized custom-made half-gutter silicone molds. Two optical FBG sensors were used to assess temperature and polymerization shrinkage. Light curing was performed for 40 s and polymerization shrinkage was evaluated at 5, 10, 40, 60, 150, and 300 s. Statistical analysis was accomplished for normal distribution (Shapiro-Wilk, p > 0.05). Two-way repeated measures ANOVA with Greenhouse-Geisser correction followed by Bonferroni's post-hoc test was used to analyze the linear shrinkage data (p < 0.05). ZFL showed the highest linear shrinkage and ADF the lowest. Shrinkage increased for all RBCs until 300 s, where significant differences were found between ADF and all other resins (p < 0.05). Among bulk-fill RBCs, TBF showed the lowest shrinkage value, but not statistically different from FBF. The ADF presented lower linear shrinkage than all other RBCs, and restorative bulk-fill composites exhibited an intermediate behavior.
    2019 article Portugal open access
  3. 3

    The force magnitude of a human bite measured at the molar intercuspidation using fiber Bragg gratings

    Publication
    by Abe,Ilda
    Other Authors: Milczewski,Maura S.; Souza,Mauren A.; Kalinowski,Hypolito J.; Machuca,Oscar F.; Marin,Gabriela C. et al.
    Origin: Oasisbr
    Abstract This study describes a localized method – using optical fiber Bragg gratings (FBGs) – to determine the human bite force at the very moment of occlusion, in maximum intercuspidation. The FBG was encapsulated in a silicone splint between uppers and lowers first molars and avoiding pre-contact with the other teeth in a dentition model. Gypsum dental castings of two volunteers are performed in a semi-adjustable articulator in the occluded situation to maintain angulations of the occlusal plane within normal occlusion. The sensor was characterized in vitro for both volunteers and the human bite force is measured in vivo. The orthodontic forces on the sensor are acquired at four moments: before of occlusion (free situation), occlusion, biting and maximum bite. The measured maximum bite forces are 85 N for female (brachyfacial) volunteer and 76 N for male (mesofacial) volunteer, between right uppers and lowers first molars. The difference can be associated to the facial pattern. The results obtained show the possibility to employ the optical encapsulated sensor to perform measurements of orthodontic forces in order to analysis different types of facial patterns with minimum of interference at occlusion.
    2017 article Brazil open access
  4. 4

    Strain, natural frequency, damping coefficient and elastic modulus of mortar beams determined by fiber Bragg grating (FBG) sensors

    Publication
    by Macioski,Gustavo
    Other Authors: Oliveira,Valmir de; Medeiros,Marcelo Henrique Farias de
    Origin: Oasisbr
    Abstract Structural health monitoring can detect anomalies in time, allowing the implementation of more efficient maintenance and repair actions in special engineering structures. An alternative in the monitoring and evaluation of structures in civil engineering is the use of optical fibers inscribed with Bragg gratings (FBG or Fiber Bragg Grating). This paper aims to compare available techniques to estimate the elastic module of cementitious composites, as well as contribute to the application of optical fiber sensors in the monitoring of strain, natural vibration frequency, damping coefficient and elastic modulus of mortar beams. The FBG sensors manufactured and calibrated by the authors presented a good precision for measuring those parameters in mortar samples. The results show that FBG sensors and strain gauge sensors present a similar result for strain and estimation of the elastic module (static and dynamic), therefore, bare FBGs could be further investigated for non-destructive testing.
    2021 article Brazil open access
  5. 5

    Optical Fiber Relative Humidity Sensor Based on a FBG with a Di-Ureasil Coating

    Publication
    by Correia, Sandra F. H.
    Other Authors: Antunes, Paulo; Pecoraro, Édison; Lima, Patricia P.; Varum, Humberto; Carlos, Luis D. et al.
    Origin: Oasisbr
    Fundação para a Ciência e a Tecnologia (FCT)
    2014 article Brazil open access