Resultados da pesquisa
Catálogo de Publicações - Todos
- A mostrar 1 - 6 resultados de 6
-
1
Kinematic Comparison and Description of the 3-Dimensional Shoulder Kinematics of 2 Shoulder Rotation Tests
Publicaçãopor Pascoal, Augusto GilOutros Autores: Morais, NunoOrigem: IC-onlineObjectives: The purpose of this study was to compare shoulder external rotation range of motion (ROM) during the hand-behind-neck (HBN) test and a standard shoulder external rotation test and to describe the 3-dimensional scapular motion during the HBN test. Methods: An electromagnetic tracking device was used to assess the dominant shoulder of 14 healthy participants while performing active full ROM in a standard shoulder external rotation test in an elevated position (EREP) and in the HBN test. The humeral and scapular 3-dimensional positions at the end of EREP and HBN were compared using a paired-sample t test. A correlation analysis was performed between humeral and scapular angles to assess the contribution of scapular motion to the full shoulder ROM during the HBN test. Results: No significant differences were found between the HBN test and the EREP at the end-range of the glenohumeral external rotation (HBN: 15.6° ± 6.3° vs EREP: 23.4° ± 4.7°; P = .08) and on scapular internal-external rotation (HBN test: 21.2° ± 6.3° vs EREP: 15.6° ± 1.8°; P = .23). Significant differences were found in scapular upward rotation (HBN: 21.2° ± 6.3° vs EREP: 15.6° ± 1.8°; P b .01) and scapular spinal tilt (HBN: − 0.4° ± 2.3° vs EREP: 8.1° ± 2.1°; P b .01). There was a positive correlation between the humeral angles and scapular internal and posterior spinal tilt angles with the HBN test. Conclusions: The results of the present study showed that, in young asymptomatic participants with no known shoulder pathology, the end-range of shoulder rotation was similar in the HBN test and in a standard shoulder rotation test. During the HBN test, the scapula assumed a more internal and anterior spinal tilted position at the end-range of active shoulder external rotation. These results suggest that the HBN test may be used to assess the end-range of glenohumeral external rotation. -
2
An open access database for the evaluation of respiratory sound classification algorithms
Publicaçãopor Rocha, Bruno MOutros Autores: Filos, Dimitris; Mendes, Luís; Serbes, Gorkem; Ulukaya, Sezer; Kahya, Yasemin P et al.Objective: Over the last few decades, there has been significant interest in the automatic analysis of respiratory sounds. However, currently there are no publicly available large databases with which new algorithms can be evaluated and compared. Further developments in the field are dependent on the creation of such databases. Approach: This paper describes a public respiratory sound database, which was compiled for an international competition, the first scientific challenge of the IFMBE’s International Conference on Biomedical and Health Informatics. The database includes 920 recordings acquired from 126 participants and two sets of annotations. One set contains 6898 annotated respiratory cycles, some including crackles, wheezes, or a combination of both, and some with no adventitious respiratory sounds. In the other set, precise locations of 10 775 events of crackles and wheezes were annotated. Main results: The best system that participated in the challenge achieved an average score of 52.5% with the respiratory cycle annotations and an average score of 91.2% with the event annotations. Significance: The creation and public release of this database will be useful to the research community and could bring attention to the respiratory sound classification problem. -
3
High-resolution seismocardiogram acquisition and analysis system
Publicaçãopor Leitão, Fábio André CostaOutros Autores: Moreira, Eurico Esteves; Alves, Filipe; Lourenço, Mário; Azevedo, Olga; Gaspar, João et al.Several devices and measurement approaches have recently been developed to perform ballistocardiogram (BCG) and seismocardiogram (SCG) measurements. The development of a wireless acquisition system (hardware and software), incorporating a novel high-resolution micro-electro-mechanical system (MEMS) accelerometer for SCG and BCG signals acquisition and data treatment is presented in this paper. A small accelerometer, with a sensitivity of up to 0.164 µs/µg and a noise density below 6.5 µg/ Hz is presented and used in a wireless acquisition system for BCG and SCG measurement applications. The wireless acquisition system also incorporates electrocardiogram (ECG) signals acquisition, and the developed software enables the real-time acquisition and visualization of SCG and ECG signals (sensor positioned on chest). It then calculates metrics related to cardiac performance as well as the correlation of data from previously performed sessions with echocardiogram (ECHO) parameters. A preliminarily clinical study of over 22 subjects (including healthy subjects and cardiovascular patients) was performed to test the capability of the developed system. Data correlation between this measurement system and echocardiogram exams is also performed. The high resolution of the MEMS accelerometer used provides a better signal for SCG wave recognition, enabling a more consistent study of the diagnostic capability of this technique in clinical analysis. -
4
Validation of wireless sensors for psychophysiological studies
Publicaçãopor Moreira, Pedro SilvaOutros Autores: Chaves, Pedro; Dias, Ruben; Dias, Nuno; Almeida, Pedro R.James One (MindProber Labs) is a wireless psychophysiological device comprising two sensors: one measuring electrodermal activity (EDA), the other photoplethysmography (PPG). This paper reports the validation of James One's EDA sensor by comparing its signal against a research grade polygraph. Twenty participants were instructed to perform breathing exercises to elicit the modulation of EDA and heart rate, while the physiological signal was captured simultaneously on James One and a Biopac MP36. The resulting EDA and PPG records collected from both systems were comprehensively compared. Results suggest that James One captures EDA signal with a quality comparable to a research grade equipment, this constituting a reliable means of capturing data while minimizing setup time and intrusiveness. -
5
Components of the acoustic swallowing signal: Preliminary study
Publicaçãopor Spadotto, André AugustoOutros Autores: Gatto, Ana Rita; Cola, Paula Cristina; Silva, Roberta Gonçalves da; Schelp, Arthur Oscar; Domenis, Danielle Ramos et al.Origem: OasisbrPurpose: To analyze the components of the acoustic signal of swallowing using a specific software. Methods: Fourteen healthy subjects ranging in age from 20 to 50 years (mean age 31±10 years), were evaluated. Data collection consisted on the simultaneous capture of the swallowing audio with a microphone and of the swallowing videofluoroscopic image. The bursts of the swallowing acoustic signal were identified and their duration and the interval between them were later analyzed using a specific software, which allowed the simultaneous analyses between the acoustic wave and the videofluoroscopic image. Results: Three burst components were identified in most of the swallows evaluated. The first burst presented mean time of 87.3 milliseconds (ms) for water and 78.2 for the substance. The second burst presented mean time of 112.9 ms for water and 85.5 for the pasty substance. The mean interval between first and second burst was 82.1 ms for water and 95.3 ms for the pasty consistency, and between second and third burst was 339.8 ms for water and 322.0 ms for the pasty consistency. Conclusion: The software allowed the visualization of three bursts during the swallowing of healthy individuals, and showed that the swallowing signal in normal subjects is highly variable. -
6
Mandible protrusion and decrease of TMJ sounds: An electrovibratographic examination
Publicaçãopor Garcia, Alicio RosalinoOutros Autores: Folli, Sérgio; Zuim, Paulo Renato Junqueira; de Sousa, ValdirOrigem: OasisbrThis study quantified by, electrovibratography, the amount of mandible protrusion required to decrease significantly temporomandibular joint (TMJ) vibratory energy as an aid in the diagnosis of the recapture of anteriorly displaced disk. Eighteen patients diagnosed as having anterior disk displacement with reduction and TMJ clicking were submitted to electrovibratographic examination at the first appointment and treated with a stabilizing appliance and anterior positioning appliance with 1 to 5 mm protrusion. Vibratory energy was checked in each of these positions. Baseline data were used as control. At the first appointment, the patients had vibrations with more elevated intensities at the middle and late phases of the mouth opening cycle. At only one clinical step, mandible protrusion was obtained with the anterior repositioning appliance, ranging from 1 to 5 mm protusion. At each new position, a new electrovibratographic exam was made. After the 5-mm mandibular projection, only 2 patients presented vibration, with means between 0.6 and 2.8 Hz. Data were analyzed statistically by ANOVA and Tukey's test (α=0.05). The outcomes of this study indicate that 3 mm is the minimum amount of mandible protrusion to significantly decrease the TMJ vibratory energy and to recapture the displaced articular disk.
Ferramentas de pesquisa:
Filtros
Page will reload when a filter is selected or excluded.- Almeida, Pedro R. 1 results 1
- Alves, Filipe 1 results 1
- Azevedo, Olga 1 results 1
- Chaves, Pedro 1 results 1
- Chouvarda, Ioanna 1 results 1
- Cola, Paula Cristina 1 results 1
- Dantas, Roberto Oliveira 1 results 1
- Dias, Nuno 1 results 1
- Dias, Ruben 1 results 1
- Domenis, Danielle Ramos 1 results 1
- Filos, Dimitris 1 results 1
- Folli, Sérgio 1 results 1
- Garcia, Alicio Rosalino 1 results 1
- Gaspar, João 1 results 1
- Gatto, Ana Rita 1 results 1
- Jakovljevic, Nikša 1 results 1
- Jácome, Cristina 1 results 1
- Kahya, Yasemin P 1 results 1
- Kaimakamis, Evangelos 1 results 1
- Leitão, Fábio André Costa 1 results 1
- Lourenço, Mário 1 results 1
- Maglaveras, Nicos 1 results 1
- Marques, Alda 1 results 1
- Mendes, Luís 1 results 1
- Morais, Nuno 1 results 1
- Moreira, Eurico Esteves 1 results 1
- Moreira, Pedro Silva 1 results 1
- Natsiavas, Pantelis 1 results 1
- Oliveira, Ana 1 results 1
- Pascoal, Augusto Gil 1 results 1
- Ver todos...
- Female 6 results 6
- Humans 6 results 6
- Male 6 results 6
- Signal Processing, Computer-Assisted
- Adult 5 results 5
- Young Adult 3 results 3
- Aged 2 results 2
- Algorithms 2 results 2
- Heart Rate 2 results 2
- Middle Aged 2 results 2
- Range of Motion, Articular 2 results 2
- Vibration 2 results 2
- Wireless Technology 2 results 2
- adult 2 results 2
- female 2 results 2
- human 2 results 2
- male 2 results 2
- methodology 2 results 2
- physiology 2 results 2
- signal processing 2 results 2
- Accelerometry 1 results 1
- Acoustics 1 results 1
- Adolescent 1 results 1
- Auscultation 1 results 1
- Ballistocardiography 1 results 1
- Biomechanical Phenomena 1 results 1
- Cardiovascular Diseases 1 results 1
- Centric Relation 1 results 1
- Child 1 results 1
- Child, Preschool 1 results 1
- Ver todos...