Search Results

Publication Catalog - All

  • Showing 1 - 4 results of 4
Refine Results
  1. 1

    The influence of size and shape of Nd:YAG capsulotomy on visual acuity and refraction

    Publication
    by Cetinkaya,Servet
    Other Authors: Cetinkaya,Yasemin Fatma; Yener,Halil Ibrahim; Dadaci,Zeynep; Ozcimen,Muammer; Acir,Nursen Oncel
    Origin: Oasisbr
    ABSTRACTPurpose:To evaluate the influence of size and shape of neodymium:yttrium aluminum- Garnet (Nd:YAG) laser capsulotomy on visual acuity and refraction.Methods:We retrospectively evaluated 85 eyes of 67 patients treated with Nd:YAG laser posterior capsulotomy for posterior capsule opacification (PCO). The mean age of included patients was 57.57 ± 9.26 (mean ± standard deviation, 38-75 years). The mean interval between surgery and Nd:YAG laser capsulotomy was 26.09 ± 7.08 (10-38) months. Patients were divided into four groups according to the shape and size of capsulotomy. Groups comprised patients with cruciate shape capsulotomies with openings of less than or equal to 3.5 mm (Group 1) or greater (Group 2) and patients with circular shape capsulotomies with openings of less than or equal to 3.5 mm (Group 3) or greater (Group 4).Results:The mean number and energy of laser firings were significantly higher in Group 4 (p=0.00), and significantly lower in Group 1 (p=0.00), compared with that in other groups. Pre-procedural and post-procedural mean spherical equivalent (SE) values were significantly higher in Group 1 (p=0.026 and p=0.011, respectively). No statistical difference in best-corrected visual acuities (BCVA) or intraocular pressures (IOP) were observed between groups before (p=0.44 and p=0.452, respectively) or after capsulotomy (p=0.108 and p=0.125, respectively). A significantly higher number of patients in Group 4 (p=0.001), and a significantly lower number of patients in Group 1 (p=0.001), reported floating bodies compared with that in other groups. No significant changes in SE or intraocular pressure were observed after capsulotomy in any group (p=0.074 and p=0.856, respectively). Best-corrected visual acuity was significantly improved following capsulotomy in all groups (p<0.01).Conclusion:Cruciate shape capsulotomy with an opening of 3.5 mm or less provides the greatest improvement in visual function with minimal complications.
    2015 article Brazil open access
  2. 2

    Sutureless transconjunctival intrascleral intraocular lens fixation: the modified Yamane technique

    Publication
    by Yavuzer,Kamil
    Other Authors: Evcimen,Yusuf
    Origin: Oasisbr
    ABSTRACT Purpose: To evaluate the efficacy and safety of the modified Yamane technique with sutureless transconjunctival intrascleral intraocular lens fixation. Methods: Sutureless transconjunctival intrascleral haptic fixated intraocular lens implantation was performed in patients with aphakia and dislocated intraocular lenses. A clear corneal incision (2.8 mm) was made into the temporal quadrant and a three-piece intraocular lens was implanted into the anterior chamber. The haptics of the intraocular lens were externalized with a 27 G needle via transconjunctival scleral tunnels at the 6 and 12 o’clock positions. The transconjunctival scleral tunnels were prepared to conform to the haptic position and curvature. The site of the scleral tunnels was 2mm from the limbus with a length of 2 mm in the sclera and was aimed at the end of the posterior chamber. The tips of the haptics were cauterized to create a terminal knob. The haptics were pushed back and the knobs were implanted into the scleral tunnels. Results: The study cohort included 21 patients with unilateral aphakia and dislocated intraocular lenses. All patients were examined postoperatively and at postoperative day 1, day 7, month 1, and month 3. All examinations revealed formation of the anterior chamber and well-centralized intraocular lenses. No haptic-related complications of exposure, foreign body sensation, or discomfort were observed. Conclusion: Sutureless transconjunctival intrascleral haptic fixated intraocular lensimplantation is an effective, safe, and practical surgical alternative. This technique was superior to the Yamane method with regard to comfort and surgical duration. Further studies with longer follow-up evaluations are warranted to verify long-term complications.
    2019 article Brazil open access
  3. 3

    Trocar-assisted intrascleral sutureless fixation of a dislocated three-piece sulcus intraocular lens

    Publication
    by Karadag,Remzi
    Other Authors: Gunes,Bahar; Demiorok,Ahmet
    Origin: Oasisbr
    ABSTRACT Trocar-assisted intraocular lens (IOL) reposition surgery using a scleral fixation method was performed for a patient with a dislocated sulcus IOL. Two 3-mm-long scleral tunnels 2 mm from and parallel to the limbus were formed using a 23-gauge vitrectomy trocar transconjunctivally entering the sclera at an angle of approximately 10°. Haptics were collected using a 23-gauge serrated retinal forceps entering from the trocar cannula and externalized from the scleral tunnels together with the trocar. The same procedure was applied for the other haptic. Both haptics were pushed into the scleral tunnel and a transconjunctival secure 10-0 nylon suture was placed at the scleral tunnel entry site around the haptic. Sutures were removed 1 week later. No complications occurred intraoperatively or postoperatively. At a 10-month follow-up, IOL was stabilized. IOL reposition surgery using the trocar-assisted IOL scleral fixation method is a viable alternative to intrascleral fixation surgery.
    2017 report Brazil open access
  4. 4

    Bilateral clear lens extraction and intraocular lens implantation in a child with microspherophakia and Marfan syndrome

    Publication
    by Farat, Joyce Godoy
    Other Authors: Nascimento Queiroz, Marjorie Fornazier; Lottelli, Antonio Carlos
    Origin: Oasisbr
    We report the case of a 4-year-old boy with Marfan syndrome whose parents reported he had had low visual acuity since birth. On examination, there was microspherophakia and a small subluxation of the lens. The objective refraction was -23.75 - 2.75 x 70 in the right eye and -25.50 -3.50 x 90 in the left eye. Since the microspherophakia and the high myopia severely affected the boy's quality of life, clear lens extraction, anterior vitrectomy, posterior surgical capsulotomy via the pars plana, and intraocular lens implantation were performed. Two years postoperatively, the patient had centered intraocular lenses and a corrected visual acuity of 20/30 in both eyes. The child was satisfied with his vision and was able to study and perform daily activities without visual limitations.
    2019 article Brazil open access